Liana Hsu1,2, Bruce Buckingham1,2, Marina Basina2,3, Laya Ekhlaspour1,2, Rie von Eyben4, Justin Wang2, Rayhan A Lal1,2,3. 1. Division of Endocrinology, Department of Pediatrics, Stanford University School of Medicine, Stanford, California, USA. 2. Stanford Diabetes Research Center, Stanford, California, USA. 3. Division of Endocrinology, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA. 4. Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California, USA.
Abstract
Background: This study assessed the efficacy and safety of ultrarapid insulin Fiasp® in the hybrid closed-loop MiniMed™ 670G system. Methods: This was a pilot randomized double-blinded crossover study among established MiniMed™ 670G users comparing percentage time in range (TIR) and hypoglycemia for Novolog® and Fiasp. After 2 weeks optimization with their home insulin, participants were randomized to receive Novolog or Fiasp for 2 weeks, followed by the other insulin for the next 2 weeks. Data from the second week of blinded insulin use were analyzed to allow 1 week for 670G adaptation. During the second week, individuals were asked to eat the same breakfast for 3 days to assess differences in meal pharmacodynamics. Results: Nineteen adults were recruited with mean age of 40 ± 18 years, diabetes duration of 27 ± 12 years, and median hemoglobin A1c of 7.1% (6.9, 7.5), using 0.72 (0.4, 1.2) units/(kg·day). For Novolog and Fiasp, respectively, the %TIR (70-180 mg/dL) was 75.3 ± 9.5 and 78.4 ± 9.3; %time <70 mg/dL was 3.1 ± 2.1 and 2.3 ± 2.0; %time >180 mg/dL was 21.6 ± 9.0 and 19.3 ± 8.9; mean glucose was 147 ± 12 and 146 ± 12 mg/dL; coefficient of variation was 28.6% ± 4.5% and 26.8% ± 4.4%; %time in auto mode 86.4 ± 9.2 and 84.4 ± 9.2. All comparisons were nonsignificant for insulin type. Total daily dose (Novolog 48.8 ± 28.4 vs. Fiasp 52.4 ± 31.7 units; P = 0.01) and daily basal (Novolog 17.6 [15.5, 33.8] vs. Fiasp 19.1 [15.3, 38.5] units; P = 0.07) correlated with TIR and %time >180 mg/dL. For insulin delivery in auto mode there was no statistical difference in total daily dose or daily basal between arms. Paired analysis for matched breakfast meals revealed no significant differences in time to maximum glucose, peak glucose, or glucose excursion. Conclusions: In this pilot study, the use of either Novolog or Fiasp in a commercially available MiniMed 670G system operating in auto mode resulted in clinically similar glycemic outcomes, with a slight increase in daily insulin requirements using Fiasp.
Background: This study assessed the efficacy and safety of ultrarapid insulin Fiasp® in the hybrid closed-loop MiniMed™ 670G system. Methods: This was a pilot randomized double-blinded crossover study among established MiniMed™ 670G users comparing percentage time in range (TIR) and hypoglycemia for Novolog® and Fiasp. After 2 weeks optimization with their home insulin, participants were randomized to receive Novolog or Fiasp for 2 weeks, followed by the other insulin for the next 2 weeks. Data from the second week of blinded insulin use were analyzed to allow 1 week for 670G adaptation. During the second week, individuals were asked to eat the same breakfast for 3 days to assess differences in meal pharmacodynamics. Results: Nineteen adults were recruited with mean age of 40 ± 18 years, diabetes duration of 27 ± 12 years, and median hemoglobin A1c of 7.1% (6.9, 7.5), using 0.72 (0.4, 1.2) units/(kg·day). For Novolog and Fiasp, respectively, the %TIR (70-180 mg/dL) was 75.3 ± 9.5 and 78.4 ± 9.3; %time <70 mg/dL was 3.1 ± 2.1 and 2.3 ± 2.0; %time >180 mg/dL was 21.6 ± 9.0 and 19.3 ± 8.9; mean glucose was 147 ± 12 and 146 ± 12 mg/dL; coefficient of variation was 28.6% ± 4.5% and 26.8% ± 4.4%; %time in auto mode 86.4 ± 9.2 and 84.4 ± 9.2. All comparisons were nonsignificant for insulin type. Total daily dose (Novolog 48.8 ± 28.4 vs. Fiasp 52.4 ± 31.7 units; P = 0.01) and daily basal (Novolog 17.6 [15.5, 33.8] vs. Fiasp 19.1 [15.3, 38.5] units; P = 0.07) correlated with TIR and %time >180 mg/dL. For insulin delivery in auto mode there was no statistical difference in total daily dose or daily basal between arms. Paired analysis for matched breakfast meals revealed no significant differences in time to maximum glucose, peak glucose, or glucose excursion. Conclusions: In this pilot study, the use of either Novolog or Fiasp in a commercially available MiniMed 670G system operating in auto mode resulted in clinically similar glycemic outcomes, with a slight increase in daily insulin requirements using Fiasp.
Authors: Satish K Garg; Stuart A Weinzimer; William V Tamborlane; Bruce A Buckingham; Bruce W Bode; Timothy S Bailey; Ronald L Brazg; Jacob Ilany; Robert H Slover; Stacey M Anderson; Richard M Bergenstal; Benyamin Grosman; Anirban Roy; Toni L Cordero; John Shin; Scott W Lee; Francine R Kaufman Journal: Diabetes Technol Ther Date: 2017-01-30 Impact factor: 6.118
Authors: Chantal Mathieu; Bruce W Bode; Edward Franek; Athena Philis-Tsimikas; Ludger Rose; Tina Graungaard; Anne Birk Østerskov; David Russell-Jones Journal: Diabetes Obes Metab Date: 2018-02-04 Impact factor: 6.577
Authors: David C Klonoff; Mark L Evans; Wendy Lane; Hans-Peter Kempe; Eric Renard; J Hans DeVries; Tina Graungaard; Agon Hyseni; Theis Gondolf; Tadej Battelino Journal: Diabetes Obes Metab Date: 2019-01-13 Impact factor: 6.577
Authors: Tadej Battelino; Thomas Danne; Richard M Bergenstal; Stephanie A Amiel; Roy Beck; Torben Biester; Emanuele Bosi; Bruce A Buckingham; William T Cefalu; Kelly L Close; Claudio Cobelli; Eyal Dassau; J Hans DeVries; Kim C Donaghue; Klemen Dovc; Francis J Doyle; Satish Garg; George Grunberger; Simon Heller; Lutz Heinemann; Irl B Hirsch; Roman Hovorka; Weiping Jia; Olga Kordonouri; Boris Kovatchev; Aaron Kowalski; Lori Laffel; Brian Levine; Alexander Mayorov; Chantal Mathieu; Helen R Murphy; Revital Nimri; Kirsten Nørgaard; Christopher G Parkin; Eric Renard; David Rodbard; Banshi Saboo; Desmond Schatz; Keaton Stoner; Tatsuiko Urakami; Stuart A Weinzimer; Moshe Phillip Journal: Diabetes Care Date: 2019-06-08 Impact factor: 19.112
Authors: Roy W Beck; Steven J Russell; Edward R Damiano; Firas H El-Khatib; Katrina J Ruedy; Courtney Balliro; Zoey Li; Peter Calhoun Journal: Diabetes Technol Ther Date: 2022-10 Impact factor: 7.337
Authors: Stuart A Weinzimer; Ryan J Bailey; Richard M Bergenstal; Revital Nimri; Roy W Beck; Desmond Schatz; Louise Ambler-Osborn; Darja Smigoc Schweiger; Thekla von dem Berge; Judy Sibayan; Mary L Johnson; Peter Calhoun; Moshe Phillip Journal: Diabetes Technol Ther Date: 2022-04-28 Impact factor: 7.337