Literature DB >> 32509914

Three-dimensional Fourier-based reprojection analytic reconstruction from histoprojections for high-resolution time-of-flight positron emission tomography scanners.

Vladimir Y Panin1, Samuel Matej2.   

Abstract

Purpose: In spite of the general acceptance of iterative reconstruction for clinical use, analytic algorithms provide an important alternative tool due to their linearity, unbiased performance, and predictability for quantitative imaging and quality control studies. On modern time-of-flight (TOF) positron emission tomography scanners with excellent timing resolution, substantial angular compression of (histoprojection) data is possible without loss of resolution, but this also brings challenges for analytical algorithms. We propose TOF and non-TOF Fourier-based analytic approaches that appropriately handle the data sparsity on modern TOF systems. Approach: The proposed TOF algorithm (3D-DIFTOF-direct inversion Fourier transform for TOF) works directly on histoprojection data. The proposed Fourier-based approaches for histoprojection data are further extended to include non-TOF reconstruction (TOF-binned 3D-DIFT), which is particularly useful in time calibration procedures due to its insensitivity to time calibration errors. TOF information is used here to extend available histoprojection data to a larger number of views, essential for artifact-free non-TOF reconstruction. The proposed algorithms are compared with standard analytic techniques on Siemens scanners-space-based confidence-weighted TOF FBP and non-TOF DIFT.
Results: 3D-DIFTOF reconstruction demonstrates both improved NEMA-based resolution and contrast versus background variability trade-offs. Similarly, the TOF-binned 3D-DIFT approach shows improved contrast-noise trade-offs over the standard non-TOF approach and is well suited for timing calibration. Conclusions: Our results demonstrate that the proposed 3D-DIFTOF technique provides an improved and more faithful characterization of image resolution compared with standard space-based analytic reconstructions. The proposed tools also provide accurate translation of sparse TOF data available on clinical scanners to upsampled data for non-TOF algorithms.
© 2020 Society of Photo-Optical Instrumentation Engineers (SPIE).

Entities:  

Keywords:  analytical reconstruction; positron tomography; time of flight

Year:  2020        PMID: 32509914      PMCID: PMC7265037          DOI: 10.1117/1.JMI.7.3.032505

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  14 in total

1.  A unified Fourier theory for time-of-flight PET data.

Authors:  Yusheng Li; Samuel Matej; Scott D Metzler
Journal:  Phys Med Biol       Date:  2015-12-22       Impact factor: 3.609

2.  First experimental results of time-of-flight reconstruction on an LSO PET scanner.

Authors:  Maurizio Conti; Bernard Bendriem; Mike Casey; Mu Chen; Frank Kehren; Christian Michel; Vladimir Panin
Journal:  Phys Med Biol       Date:  2005-09-13       Impact factor: 3.609

3.  Fourier rebinning of time-of-flight PET data.

Authors:  Michel Defrise; Michael E Casey; Christian Michel; Maurizio Conti
Journal:  Phys Med Biol       Date:  2005-05-25       Impact factor: 3.609

4.  Fast reconstruction of 3D time-of-flight PET data by axial rebinning and transverse mashing.

Authors:  Stefaan Vandenberghe; Margaret E Daube-Witherspoon; Robert M Lewitt; Joel S Karp
Journal:  Phys Med Biol       Date:  2006-03-01       Impact factor: 3.609

5.  Analytical properties of time-of-flight PET data.

Authors:  Sanghee Cho; Sangtae Ahn; Quanzheng Li; Richard M Leahy
Journal:  Phys Med Biol       Date:  2008-05-06       Impact factor: 3.609

6.  A Quantitative Evaluation of Joint Activity and Attenuation Reconstruction in TOF PET/MR Brain Imaging.

Authors:  Ahmadreza Rezaei; Georg Schramm; Stefanie M A Willekens; Gaspar Delso; Koen Van Laere; Johan Nuyts
Journal:  J Nucl Med       Date:  2019-04-12       Impact factor: 10.057

7.  Effect of attenuation mismatches in time of flight PET reconstruction.

Authors:  Elise C Emond; Alexandre Bousse; Maria Machado; Joanna Porter; Ashley M Groves; Brian F Hutton; Kris Thielemans
Journal:  Phys Med Biol       Date:  2020-04-20       Impact factor: 3.609

8.  Comparison of list-mode and DIRECT approaches for time-of-flight PET reconstruction.

Authors:  Margaret E Daube-Witherspoon; Samuel Matej; Matthew E Werner; Suleman Surti; Joel S Karp
Journal:  IEEE Trans Med Imaging       Date:  2012-03-06       Impact factor: 10.048

9.  Analytic TOF PET reconstruction algorithm within DIRECT data partitioning framework.

Authors:  Samuel Matej; Margaret E Daube-Witherspoon; Joel S Karp
Journal:  Phys Med Biol       Date:  2016-04-01       Impact factor: 3.609

10.  Efficient 3-D TOF PET reconstruction using view-grouped histo-images: DIRECT-direct image reconstruction for TOF.

Authors:  Samuel Matej; Suleman Surti; Shridhar Jayanthi; Margaret E Daube-Witherspoon; Robert M Lewitt; Joel S Karp
Journal:  IEEE Trans Med Imaging       Date:  2009-01-13       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.