PROCEDURES TO MEASURE MEAN AMBIENT DOSE EQUIVALENT RATES USING ELECTRET ION CHAMBERS.

F Leontaris1, A Boziari2, A Clouvas1, M Kolovou2, J Guilhot1.   

Abstract

The capabilities of electret ion chambers (EICs) to measure mean ambient dose equivalent rates were investigated by performing both laboratory and field studies of their properties. First, EICs were 'calibrated' to measure ambient gamma dose equivalent in the Ionizing Calibration Laboratory of the Greek Atomic Energy Commission. The EICs were irradiated with different gamma photon energies and from different angles. Calibration factors were deduced (electret's voltage drop due to irradiation in terms of ambient dose equivalent). In the field studies, EICs were installed at eight locations belonging to the Greek Early Warning System Network (which is based on Reuter-Stokes ionization chambers) for three periods, averaging 5 months each. In the same locations, in situ gamma spectrometry measurements were performed with portable germanium detectors. Gamma ambient dose equivalent rates were deduced by the in situ gamma spectrometry measurements and by soil sample analysis. The mean daily electret potential drop (in Volts) was compared with the mean daily ambient dose equivalent, measured with a portable HPGe detector and Reuter-Stokes high-pressure ionization chambers. From these measurements, 'field' calibration factors (electret's voltage drop due to gamma radiation in terms of ambient dose equivalent) were deduced and found in very good agreement with the values deduced in Laboratory. The influence of cosmic radiation and the intrinsic voltage loss when performing long-term environmental gamma measurements with EICs, was estimated.
© The Author(s) 2020. Published by Oxford University Press.

Entities:  

Mesh:

Year:  2020        PMID: 32488254      PMCID: PMC7397567          DOI: 10.1093/rpd/ncaa061

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  11 in total

1.  Pilot study of indoor radon in Greek workplaces.

Authors:  A Clouvas; S Xanthos; M Antonopoulos-Domis
Journal:  Radiat Prot Dosimetry       Date:  2007-01-05       Impact factor: 0.972

2.  Specific activity to H*(10) conversion coefficients for in situ gamma spectrometry.

Authors:  M Lemercier; R Gurriaran; P Bouisset; X Cagnat
Journal:  Radiat Prot Dosimetry       Date:  2007-10-17       Impact factor: 0.972

3.  Leakage correction estimate for electret ion chamber dielectric material used for long-term environmental gamma monitoring.

Authors:  David F Jones; L R Paulus
Journal:  Health Phys       Date:  2008-05       Impact factor: 1.316

4.  EURADOS intercomparison 2006 to harmonise European early warning dosimetry systems.

Authors:  H Dombrowski; S Neumaier; I M G Thompson; F Wissmann
Journal:  Radiat Prot Dosimetry       Date:  2009-06-13       Impact factor: 0.972

5.  A practical E-PERM (electret passive environmental radon monitor) system for indoor 222Rn measurement.

Authors:  P Kotrappa; J C Dempsey; R W Ramsey; L R Stieff
Journal:  Health Phys       Date:  1990-04       Impact factor: 1.316

6.  Area dose rate values derived from NaI or LaBr3 spectra.

Authors:  H Dombrowski
Journal:  Radiat Prot Dosimetry       Date:  2014-01-28       Impact factor: 0.972

7.  Calibration factors for Ge detectors used for field spectrometry.

Authors:  I K Helfer; K M Miller
Journal:  Health Phys       Date:  1988-07       Impact factor: 1.316

8.  Field test of electret ion chambers for environmental monitoring.

Authors:  R A Fjeld; K J Montague; M H Haapala; P Kotrappa
Journal:  Health Phys       Date:  1994-02       Impact factor: 1.316

9.  Variations observed in environmental radiation at ground level.

Authors:  F Wissmann
Journal:  Radiat Prot Dosimetry       Date:  2005-06-28       Impact factor: 0.972

10.  RESPONSE OF THE GREEK EARLY WARNING SYSTEM REUTER-STOKES IONIZATION CHAMBERS TO TERRESTRIAL AND COSMIC RADIATION EVALUATED IN COMPARISON WITH SPECTROSCOPIC DATA AND TIME SERIES ANALYSIS.

Authors:  F Leontaris; A Clouvas; S Xanthos; A Maltezos; C Potiriadis; E Kiriakopoulos; J Guilhot
Journal:  Radiat Prot Dosimetry       Date:  2018-02-01       Impact factor: 0.972

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.