| Literature DB >> 32479758 |
Mustafa K Özçürümez1, Andreas Ambrosch2, Oliver Frey3, Verena Haselmann4, Stefan Holdenrieder5, Michael Kiehntopf6, Michael Neumaier4, Michael Walter7, Folker Wenzel8, Roman Wölfel9, Harald Renz10.
Abstract
Severe acute respiratory syndrome coronavirus 2 infection and development of coronavirus disease 2019 presents a major health care challenge of global dimensions. Laboratory diagnostics of infected patients, and the assessment of immunity against severe acute respiratory syndrome coronavirus 2, presents a major cornerstone in handling the pandemic. Currently, there is an increase in demand for antibody testing and a large number of tests are already marketed or are in the late stage of development. However, the interpretation of test results depends on many variables and factors, including sensitivity, specificity, potential cross-reactivity and cross-protectivity, the diagnostic value of antibodies of different isotypes, and the use of antibody testing in identification of acutely ill patients or in epidemiological settings. In this article, the recently established COVID-19 Task Force of the German Society for Clinical Chemistry and Laboratory Medicine (DGKL) addresses these issues on the basis of currently available data sets in this rapidly moving field.Entities:
Keywords: Antibody response; COVID-19; diagnostic pathway; external quality assurance; immunity; immunoassay; neutralization assay; respiratory tract infections; serologic tests; severe acute respiratory syndrome coronavirus 2
Mesh:
Substances:
Year: 2020 PMID: 32479758 PMCID: PMC7256507 DOI: 10.1016/j.jaci.2020.05.020
Source DB: PubMed Journal: J Allergy Clin Immunol ISSN: 0091-6749 Impact factor: 10.793
Fig 1Positive predictive values for 21 commercial SARS-CoV-2 immunoassays and 1 laboratory-developed assay detecting IgM and IgG antibodies (total of 14 test systems) in patient sera and controls. Data were extracted from Whitman et al and plotted against various prevalence settings (0.08%-25.6%). Letters on the horizontal axis refer to the following assays: M: Inhouse; K: Epitope Diagnostics IgG; I2: VivaChek IgG; H2: UCP IgG; G2: Sure IgG; F2: Premier IgG; E2: Innovita IgG; D2: DeepBlue IgG; C2: Decombio IgG; B2: Bioperfectus IgG; A2: Biomedomics IgG; L: Wondito IgG/IgM; K1: Epitope Diagnostics IgM; I1: VivaChek IgM; H1: UCP IgM; G1: Sure IgM; F1: Premier IgM; E1: Innovita IgM; D1: DeepBlue IgM; C1: Decombio IgM; B1: Bioperfectus IgM; A1: BioMedomics IgM.
Fig 2Examples of PPV (A) and NPV (B) (y-axis) as a function of prevalence (x-axis). Gray lines illustrate a theoretically assumed range of test sensitivities/specificities from 80/80% to 99.9/99.9%, as indicated, respectively. Two commercially available SARS-CoV-2 IgG tests are shown with (Fig 2, A) specificities of 90.6% (blue) and 98.5% (red), and (Fig 2, B) sensitivities of 88.7% (blue) and 80.0% (red), respectively. PPV for a population-based prevalence of 0.24% for COVID-19 (Regensburg, Bavaria) and 0.9% are illustrated in the insert of plot (Fig 2, A). As obvious in Fig 2, B, even though assay sensitivity is only 80%, due to its higher specificity the red line is located above the gray line that indicates prevalence-dependent NPV for sensitivities/specificities of 80%, respectively.
Synopsis of available SARS-CoV-2 serological techniques
| Technique | Rationale for usage | Advantages | Disadvantages |
|---|---|---|---|
| EIA | Monitoring of seroconversion; contact tracing; seroprevalence studies | High throughput; availability, easy to perform | Lack of knowledge on utilization and quality; inability to confirm antibodies (neutralization) functionality |
| IFT | Monitoring of seroconversion; seroprevalence studies | No analyzer (but IF microscope) needed | Low throughput; experience required; discrimination of other coronavirus antibodies; time-consuming |
| DB/WB | Confirmatory; proof of specificity/cross-reactivity; research use | Discrimination of other coronavirus antibodies | Not commonly available; experience required (WB) |
| VNT | Confirmatory; proof of specificity/cross-reactivity; virological reference method | Functional information | Biosafety level 3 laboratory necessary |
| LFA | Lack of other resources | Independent from laboratory equipment | Questionable sensitivity and specificity |
DB/WB, Dot blot/Western blot; EIA, enzyme immunoassay; IFT, immunofluorescence test; LFA, immunochromatographic lateral-flow assays; VNT, virus neutralization test.