| Literature DB >> 32479412 |
Jodie L Guest1, Patrick S Sullivan1, Mariah Valentine-Graves1, Rachel Valencia1, Elizabeth Adam1, Nicole Luisi1, Mariko Nakano2, Jeannette Guarner3, Carlos Del Rio3, Charles Sailey2, Zoe Goedecke2, Aaron J Siegler1, Travis H Sanchez3.
Abstract
BACKGROUND: The severe acute respiratory coronavirus 2 (SARS-CoV-2) pandemic calls for expanded opportunities for testing, including novel testing strategies such as home-collected specimens.Entities:
Keywords: COVID-19; diagnosis; diagnostic; home testing; pilot study; telehealth; testing
Mesh:
Year: 2020 PMID: 32479412 PMCID: PMC7318863 DOI: 10.2196/19731
Source DB: PubMed Journal: JMIR Public Health Surveill ISSN: 2369-2960
Characteristics of the iCollect pilot study participants (N=159).
| Characteristic | n (%) | |
|
|
| |
|
| 18-21 | 7 (4.4) |
|
| 22-29 | 56 (35.2) |
|
| 30-39 | 36 (22.6) |
|
| 40-49 | 23 (14.5) |
|
| 50-59 | 24 (15.1) |
|
| 60-69 | 8 (5.0) |
|
| ≥70 | 5 (3.1) |
|
|
| |
|
| White/Caucasian, non-Hispanic | 110 (69.2) |
|
| Black/African American, non-Hispanic | 12 (7.5) |
|
| Latino/Hispanic | 22 (13.8) |
|
| Asian/Pacific Islander, non-Hispanic | 8 (5.0) |
|
| Native American/Alaska native | 0 (0.0) |
|
| Mixed race, non-Hispanic | 2 (1.2) |
|
| Not reported | 5 (3.1) |
|
|
| |
|
| Female | 91 (57.2) |
|
| Male | 61 (38.4) |
|
| Genderqueer | 1 (0.6) |
|
| Multiple | 1 (0.6) |
|
| Not reported | 5 (3.1) |
|
|
| |
|
| Northeast | 43 (28.3) |
|
| Midwest | 27 (17.0) |
|
| South/Southeast | 57 (35.8) |
|
| Northwest | 8 (5.0) |
|
| West | 24 (15.1) |
|
|
| |
|
| Shortness of breath | 24 (15.1) |
|
| Fever | 9 (5.7) |
|
| Cough | 58 (36.5) |
|
| Sneezing | 36 (22.6) |
|
| Sore throat | 34 (21.4) |
|
| Headache | 49 (30.8) |
|
| Diarrhea | 18 (11.3) |
|
| Myalgia | 15 (9.4) |
|
| Feeling of being unwell | 41 (25.8) |
|
| None | 51 (32.1) |
|
| Not reported | 5 (3.1) |
|
|
| |
|
| 0 | 51 (32.1) |
|
| 1 | 21 (13.2) |
|
| 2 | 20 (12.6) |
|
| 3 | 15 (9.4) |
|
| 4 | 22 (13.8) |
|
| 5 | 6 (3.8) |
|
| 6 | 4 (2.5) |
|
| 7 | 4 (2.5) |
|
| 8 | 1 (0.6) |
|
| Not reported | 15 (9.4) |
Figure 1Participant and specimen flow of the iCollect study. DBS: dried blood spot. OPS: oropharyngeal swab.
Numbers of samples collected in the iCollect study with clinician assessment of the suitability of the collection procedures (n=153).
| Sample | Total attempted collections observed, n (%) | Total samples collected, n (%) |
| DBSa | 148b (96.7) | 145c (94.8) |
| Saliva | 153 (100.0) | 153 (100.0) |
| OPSd | 152e (99.3) | 151f, 98.7 |
aDBS: dried blood spot.
bFive DBS collections were not observed: 2 participants did not see the instructions, 2 did not have the instructions, and 1 experienced anxiety/fainting when drawing blood and did not complete the process.
cThree DBS samples were not collected: no blood.
dOPS: oropharyngeal swab.
eOne OPS collection was not observed: no swab in the kit.
fOne OPS sample was not collected: the participant vomited while attempting to collect it.
Numbers of samples assessed as suitable and unsuitable for laboratory testing.
| Sample | Clinician assessed as suitable, n (%) | Clinician assessed as unsuitable, n (%) |
| DBSa (n=145) | 135 (93.1) | 10b (6.9) |
| Saliva (n=153) | 147 (96.1) | 6c (3.9) |
| OPSd (n=151) | 146 (96.7) | 5e (3.3) |
aDBS: dried blood spot.
bTen DBS samples were unsuitable: 3 had <3 spots, 3 participants pressed their finger into the paper, 2 participants did not fill the spots completely, 1 unknown, and 1 participant did not wash their hands.
cSix saliva samples were insufficient: 4 did not invert the tube, 1 did not use the instructions and missed steps, 1 contained lots of foam.
dOPS: oropharyngeal swab.
eFive oropharyngeal swabs were insufficient: 3 participant did not swab long enough (<20 seconds), 1 participant only held the swab against the roof of the mouth, and 1 participant swabbed their cheeks.
Clinician-documented participant actions when collecting DBS samples and conducting COVID-19 self-testing during the iCollect study (n=148).
| Participant action | n (%) | |
| Labeled DBSa card, including name, date of birth, and date of collection | 145b (98.0) | |
| Did not touch blood collection paper | 136c (91.9) | |
| Washed hands before collection | 143 (96.6) | |
| Cleaned finger with alcohol pad | 143 (96.6) | |
| Used lancet on side of finger | 133 (89.9) | |
| Did not touch paper while making spots | 119b (80.4) | |
|
| ||
|
| All spots | 96 (64.9) |
|
| Some spots | 38 (25.7) |
|
| No spots | 14 (9.5) |
| Set the card aside to dry | 142d (95.9) | |
|
| ||
|
| 0 | 4 (2.7) |
|
| 1 | 2 (1.3) |
|
| 2 | 5 (3.4) |
|
| 3 | 9 (6.1) |
|
| 4 | 15 (10.1) |
|
| 5 | 113 (76.4) |
aDBS: dried blood spot.
bOne assessment missing.
cFour assessments missing.
dThree assessments missing.
Clinician-documented participant actions when collecting oropharyngeal swabs and conducting COVID-19 self-testing in the iCollect study (n=152).
| Participant action | n (%) |
| Did not drink, eat, or smoke immediately before or during collection | 151a (99.3) |
| Washed hands before collection | 135 (88.8) |
| Did not let the swab touch anything before or after collection | 148a (97.4) |
| Inserted the swab in their mouth and swabbed each side for approximately 20 seconds | 137a (90.1) |
| Placed the swab in the collection tube | 150a (98.7) |
| Broke the swab at the score line | 151a (99.3) |
| Placed the lid on the collection tube and tightened it | 150a (98.7) |
| Wrote their date of birth on the tube | 141b (92.8) |
| Placed the specimen in the biohazard bag and sealed the bag | 150a (98.7) |
aOne assessment missing.
bTwo assessments missing.
Clinician-documented participant actions when collecting saliva samples and conducting COVID-19 self-testing during the iCollect study (n=153).
| Participant action | n (%) |
| Did not drink, eat, or smoke immediately before or during collection | 152a (99.3) |
| Washed hands before collection | 135 (88.2) |
| Rinsed their mouth with water before collection | 112a (73.2) |
| Placed their lips over the funnel when providing the saliva sample | 145a (94.8) |
| Filled the tube to the red indicator line | 146b (95.4) |
| Unscrewed the funnel and put on the cap | 152a (99.3) |
| Inverted the vial 20 times | 134a (87.6) |
| Removed the barcode label and applied it to the tube | 145a (94.8) |
| Wrote their date of birth on the barcode label | 140b (91.5) |
| Placed the specimen in the biohazard bag and sealed the bag | 150b (98.0) |
aOne assessment missing.
bTwo assessments missing.