Literature DB >> 32472337

A modified method of measuring plasma volume with indocyanine green: reducing the frequency of blood sampling while maintaining accuracy.

Byung-Moon Choi1, Eun-Kyung Lee2, Kyung Mi Kim3, Do-Yang Park3, Eun-Hwa Kang4, Myojung Kim3, Gyu-Jeong Noh5.   

Abstract

Among various methods for measuring the plasma volume (PV), the indocyanine green (ICG) dilution technique is a relatively less invasive method. However, the ICG method is rather cumbersome because 10 blood samples need to be obtained within a short time after ICG administration. Thus, reducing the frequency of blood sampling while maintaining the accuracy would facilitate plasma volume measurement in clinical situations. We here developed a modified method to measure plasma volume using 2260 ICG plasma concentration data from 115 surgical patients. The mean relative error (MRE) and the percentage of cases with relative error (RE) greater than 5% in total (PRE) were used to quantify the difference between plasma volumes obtained by the original and modified methods. RE was determined as follows. RE(%) = (PV obtained by original method (PVoriginal)-PV obtained by modified method (PVmodified))/PVoriginal × 100. PVmodified was assumed to be equal to PVoriginal when the RE was < 5%. When the number of samples selected for the plasma volume estimation was 4 or less, the PRE was mostly 10% or more. Five out of the 10 blood samples (order: 1st, 2nd, 3rd, 9th, and 10th) showed similar accuracies with the plasma volume obtained by the original method (original: 2.72 ± 0.64 l, modified: 2.72 ± 0.65 l). This modified method may be able to aptly replace the original method and lead to a wider clinical application of the ICG dilution technique. Further validation is needed to determine if the results of this study may be applied in other populations.
© 2020. Springer Nature B.V.

Entities:  

Keywords:  Accuracy; Indocyanine green; Measurement; Plasma volume

Year:  2020        PMID: 32472337     DOI: 10.1007/s10877-020-00536-5

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  14 in total

1.  Haemodynamic monitoring with pulse-induced contour cardiac output (PiCCO) in critical care.

Authors:  Ros Cottis; Neil Magee; David J Higgins
Journal:  Intensive Crit Care Nurs       Date:  2003-10       Impact factor: 3.072

2.  The estimation of red cell volume with 51Cr-labelled erythrocytes and plasma volume with radioiodinated human serum albumin.

Authors:  D HART; J METZ
Journal:  J Clin Pathol       Date:  1962-09       Impact factor: 3.411

Review 3.  Technical and physiological background of plasma volume measurement with indocyanine green: a clarification of misunderstandings.

Authors:  Matthias Jacob; Peter Conzen; Udilo Finsterer; Alexander Krafft; Bernhard F Becker; Markus Rehm
Journal:  J Appl Physiol (1985)       Date:  2006-11-16

4.  CLINICAL STUDIES OF THE BLOOD VOLUME. I. CLINICAL APPLICATION OF A METHOD EMPLOYING THE AZO DYE "EVANS BLUE" AND THE SPECTROPHOTOMETER.

Authors:  J G Gibson; W A Evans
Journal:  J Clin Invest       Date:  1937-05       Impact factor: 14.808

5.  Perioperative Fluid Management: Turning Art to Science.

Authors:  Harriet W Hopf; Candice Morrissey
Journal:  Anesthesiology       Date:  2019-05       Impact factor: 7.892

6.  Do intravascular hypo- and hypervolaemia result in changes in central blood volumes?

Authors:  J J Vos; T W L Scheeren; S A Loer; A Hoeft; J K G Wietasch
Journal:  Br J Anaesth       Date:  2015-10-29       Impact factor: 9.166

7.  Changes in plasma volume before and after major abdominal surgery following stroke volume variation-guided fluid therapy: a randomized controlled trial.

Authors:  Yong-Hun Lee; Hye-Won Jang; Chan-Hye Park; Sang-Mee An; Eun-Kyoung Lee; Byung-Moon Choi; Gyu-Jeong Noh
Journal:  Minerva Anestesiol       Date:  2019-12-04       Impact factor: 3.051

8.  Measurement of blood volume using indocyanine green measured with pulse-spectrophotometry: its reproducibility and reliability.

Authors:  Y L He; H Tanigami; H Ueyama; T Mashimo; I Yoshiya
Journal:  Crit Care Med       Date:  1998-08       Impact factor: 7.598

9.  Estimation of indocyanine green elimination rate constant k and retention rate at 15 min using patient age, weight, bilirubin, and albumin.

Authors:  Ga Yeong Kim; Kyun Seop Bae; Gyu Jeong Noh; Won Ki Min
Journal:  J Hepatobiliary Pancreat Surg       Date:  2009-04-14

10.  An efficient method for measuring plasma volume using indocyanine green dye.

Authors:  Sixtus Aguree; Alison D Gernand
Journal:  MethodsX       Date:  2019-05-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.