Literature DB >> 14516759

Haemodynamic monitoring with pulse-induced contour cardiac output (PiCCO) in critical care.

Ros Cottis1, Neil Magee, David J Higgins.   

Abstract

Haemodynamic monitoring is essential for the management of the critically ill. Effective monitoring can give data that permit analysis of key circulatory functions and the anticipation of deterioration so that pro-active treatments can be initiated. There are many methods of monitoring the haemodynamic status of patients. The authors have compared three of the most commonly used methods in the general Critical Care Unit. These are the pulmonary artery catheter (PAC), oesophageal Doppler, and pulse-induced contour cardiac output (PiCCO) studies. The focus is upon PiCCO, which is a comparatively less invasive method than the traditionally used PAC. This has been chosen due to the authors' particular interest in the additional parameters which can be monitored using PiCCO. With the PiCCO system it is possible to measure intrathoracic blood volume (ITBV), extravascular lung water (EVLW) and cardiac function index (CFI). These parameters are of interest as they are considered to be the most specific measures of cardiac preload, pulmonary oedema and contractility and a global indicator of cardiac performance.

Entities:  

Mesh:

Year:  2003        PMID: 14516759     DOI: 10.1016/s0964-3397(03)00063-6

Source DB:  PubMed          Journal:  Intensive Crit Care Nurs        ISSN: 0964-3397            Impact factor:   3.072


  13 in total

1.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

2.  A modified method of measuring plasma volume with indocyanine green: reducing the frequency of blood sampling while maintaining accuracy.

Authors:  Byung-Moon Choi; Eun-Kyung Lee; Kyung Mi Kim; Do-Yang Park; Eun-Hwa Kang; Myojung Kim; Gyu-Jeong Noh
Journal:  J Clin Monit Comput       Date:  2020-05-29       Impact factor: 2.502

3.  Noninvasive photoacoustic measurement of the composite indicator dilution curve for cardiac output estimation.

Authors:  DongYel Kang; Qiaojian Huang; Youzhi Li
Journal:  Biomed Opt Express       Date:  2015-01-15       Impact factor: 3.732

4.  Extravascular lung water index and Halperin score to predict outcome in critically ill patients.

Authors:  Bernhard Wernly; Sebastian Haumann; Maryna Masyuk; Johanna Muessig; Michael Lichtenauer; Laura Bäz; Marcus Franz; Alexander Pfeil; Alexander Lauten; Paul Christian Schulze; Uta C Hoppe; Malte Kelm; Ralf Westenfeld; Christian Jung; Diane Renz
Journal:  Wien Klin Wochenschr       Date:  2018-08-09       Impact factor: 1.704

5.  Real-world extravascular lung water index measurements in critically ill patients : Pulse index continuous cardiac output measurements: time course analysis and association with clinical characteristics.

Authors:  Matthias Werner; Bernhard Wernly; Michael Lichtenauer; Marcus Franz; Bjoern Kabisch; Johanna M Muessig; Maryna Masyuk; Paul Christian Schulze; Uta C Hoppe; Malte Kelm; Alexander Lauten; Christian Jung
Journal:  Wien Klin Wochenschr       Date:  2019-05-08       Impact factor: 1.704

6.  Lung recruitment maneuver effects on respiratory mechanics and extravascular lung water index in patients with acute respiratory distress syndrome.

Authors:  Jian-Guo Zhang; Xiao-Juan Chen; Fen Liu; Zhen-Guo Zeng; Ke-Jian Qian
Journal:  World J Emerg Med       Date:  2011

7.  Are management decisions in critical patients changed with use of hemodynamic parameters from transpulmonary thermodilution technique?

Authors:  Ye Rim Chang; Seok Ho Choi; Sung Wook Chang
Journal:  Ann Transl Med       Date:  2019-08

Review 8.  Bench-to-bedside review: Resuscitation in the emergency department.

Authors:  Mohamed Y Rady
Journal:  Crit Care       Date:  2004-10-20       Impact factor: 9.097

9.  Effects of Target Temperature Management on the Outcome of Septic Patients with Fever.

Authors:  Ye Gao; Jianjun Zhu; Chenyu Yin; Jianliang Zhu; Tao Zhu; Lijun Liu
Journal:  Biomed Res Int       Date:  2017-11-12       Impact factor: 3.411

Review 10.  Clinical review: Does it matter which hemodynamic monitoring system is used?

Authors:  Davinder Ramsingh; Brenton Alexander; Maxime Cannesson
Journal:  Crit Care       Date:  2013-03-05       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.