| Literature DB >> 32454954 |
Mohammad Esmaeel Ebrahimi Chaharom1,2, Mahmoud Bahari1, Leila Safyari3, Hossein Safarvand3, Hajar Shafaei4, Elmira Jafari Navimipour1, Parnian Alizadeh Oskoee1, Amir Ahmad Ajami1, Mahdi Abed Kahnamouei1.
Abstract
Background. Due to the effect of pre-heating on the degree of conversion of composite resins and the possible effect on cytotoxicity, the effect of pre-heating of bulk-fill composite resins was investigated on cytotoxicity in this study. Methods. In this study, three different types of composite resin were used, including Tetric N-Ceram Bulk-Fil, Xtrafil, and Xtrabase. From each composite resin, 10 cylindrical samples (5 mm in diameter and 4 mm in height) were prepared, with five samples preheated to 68°C, and the other five samples polymerized at room temperature (25°C). Twenty-four hours after polymerization, cytotoxicity was assessed by MTT assay on human fibroblasts. Statistical analysis of data was carried out with two-way ANOVA and Sidak Post-Hoc. The significance level of the test was determined at 0.05. Results. There was no statistically significant difference between the mean percentage of cytotoxicity in terms of pre-heating (P>0.05), but the cytotoxicity of the studied composite resins was significantly different (P<0.001). The cytotoxicity of Tetric N-Ceram Bulk-fil composite resin was higher than that of the two other composite resins. Conclusion. Pre-heating of bulk-fill composite resin did not affect their cytotoxicity. In addition, the cytotoxicity of different bulk-fill composite resins was not the same.Entities:
Keywords: Cell survival; composite resin; tetrazolium salts
Year: 2020 PMID: 32454954 PMCID: PMC7235702 DOI: 10.34172/joddd.2020.003
Source DB: PubMed Journal: J Dent Res Dent Clin Dent Prospects ISSN: 2008-210X
Properties of the tested composite resin materials and their abbreviated codes
|
|
|
|
|
|
|
|
|
| High viscosity bulk- fill universal | Voco, Cuxhaven, Germany | 1618416 | Bis-GMA, UDMA, TEGDMA |
|
|
|
| Low viscosity bulk- fill universal | Voco, Cuxhaven, Germany | 1745721 | Bis-EMA, UDMA, TEGDMA |
|
|
|
|
High viscosity bulk- fill | Ivoclar-vivadent, Schaan, Liechtenstein | W30705 |
Bis-GMA, UDMA, |
Barium glass, ytterbium trifluoride, |
|
*Filler composition has not been specified by the manufacturer.
Means and standard deviations of cytotoxicity, in terms of pre-heating and type of composite resin (in cellular culture medium with different concentrations)
|
| |||||||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||
|
| No | 1.51 | 23.01 | .630 | 23.42 | 3.36 | 17.54 | 1.99 | 15.69 |
| Yes | 1.94 | 23.23 | 2.04 | 22.59 | 1.93 | 16.77 | 1.23 | 15.04 | |
|
| No | 1.43 | 23.72 | 2.50 | 23.24 | 3.34 | 17.68 | 0.21 | 15.04 |
| Yes | 1.58 | 23.34 | 2.90 | 23.43 | 4.28 | 17.49 | 0.22 | 15.34 | |
|
| No | 3.88 | 29.87 | 1.89 | 22.63 | 3.59 | 17.58 | .610 | 15.00 |
| Yes | 4.03 | 28.77 | 1.25 | 21.77 | 2.78 | 17.50 | 0.88 | 15.20 | |
Figure 1