Literature DB >> 25511301

Post-irradiation hardness development, chemical softening, and thermal stability of bulk-fill and conventional resin-composites.

Ruwaida Z Alshali1, Nesreen A Salim2, Julian D Satterthwaite3, Nick Silikas4.   

Abstract

OBJECTIVES: To measure bottom/top hardness ratio of bulk-fill and conventional resin-composite materials, and to assess hardness changes after dry and ethanol storage. Filler content and kinetics of thermal decomposition were also tested using thermogravimetric analysis (TGA).
METHODS: Six bulk-fill (SureFil SDR, Venus bulk fill, X-tra base, Filtek bulk fill flowable, Sonic fill, and Tetric EvoCeram bulk-fill) and eight conventional resin-composite materials (Grandioso flow, Venus Diamond flow, X-flow, Filtek Supreme Ultra Flowable, Grandioso, Venus Diamond, TPH Spectrum, and Filtek Z250) were tested (n=5). Initial and 24h (post-cure dry storage) top and bottom microhardness values were measured. Microhardness was re-measured after the samples were stored in 75% ethanol/water solution. Thermal decomposition and filler content were assessed by TGA. Results were analysed using one-way ANOVA and paired sample t-test (α=0.05).
RESULTS: All materials showed significant increase of microhardness after 24h of dry storage which ranged from 100.1% to 9.1%. Bottom/top microhardness ratio >0.9 was exhibited by all materials. All materials showed significant decrease of microhardness after 24h of storage in 75% ethanol/water which ranged from 14.5% to 74.2%. The extent of post-irradiation hardness development was positively correlated to the extent of ethanol softening (R(2)=0.89, p<0.001). Initial thermal decomposition temperature assessed by TGA was variable and was correlated to ethanol softening.
CONCLUSIONS: Bulk-fill resin-composites exhibit comparable bottom/top hardness ratio to conventional materials at recommended manufacturer thickness. Hardness was affected to a variable extent by storage with variable inorganic filler content and initial thermal decomposition shown by TGA. CLINICAL SIGNIFICANCE: The manufacturer recommended depth of cure of bulk-fill resin-composites can be reached based on the microhardness method. Characterization of the primary polymer network of a resin-composite material should be considered when evaluating its stability in the aqueous oral environment.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bulk-fill; Cross-link density; Microhardness; Post-irradiation; Resin-composite; Thermogravimetric analysis

Mesh:

Substances:

Year:  2014        PMID: 25511301     DOI: 10.1016/j.jdent.2014.12.004

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  16 in total

1.  Class II composite resin restorations: faster, easier, predictable.

Authors:  R D Jackson
Journal:  Br Dent J       Date:  2016-11-18       Impact factor: 1.626

2.  Polymerization pattern characterization within a resin-based composite cured using different curing units at two distances.

Authors:  Afnan O Al-Zain; George J Eckert; Henry Lukic; Spiro Megremis; Jeffrey A Platt
Journal:  Clin Oral Investig       Date:  2019-02-09       Impact factor: 3.573

3.  Influence of cleaning methods after 3D printing on two-body wear and fracture load of resin-based temporary crown and bridge material.

Authors:  Johannes Mayer; Bogna Stawarczyk; Konstantin Vogt; Reinhard Hickel; Daniel Edelhoff; Marcel Reymus
Journal:  Clin Oral Investig       Date:  2021-04-03       Impact factor: 3.573

4.  The effect of pre-heating on monomer elution from bulk-fill resin composites.

Authors:  Mohammad-Esmaeel Ebrahimi-Chaharom; Leila Safyari; Hossein Safarvand; Elmira Jafari-Navimipour; Parnian Alizadeh-Oskoee; Amir-Ahmad Ajami; Mahdi Abed-Kahnamouei; Mahmoud Bahari
Journal:  J Clin Exp Dent       Date:  2020-09-01

5.  Curing characteristics of flowable and sculptable bulk-fill composites.

Authors:  Vesna Miletic; Pong Pongprueksa; Jan De Munck; Neil R Brooks; Bart Van Meerbeek
Journal:  Clin Oral Investig       Date:  2016-07-06       Impact factor: 3.573

6.  Food Simulating Organic Solvents for Evaluating Crosslink Density of Bulk Fill Composite Resin.

Authors:  Neveen M Ayad; Hala A Bahgat; Eman Hussain Al Kaba; Maryam Hussain Buholayka
Journal:  Int J Dent       Date:  2017-04-12

7.  Effect of preheating on the cytotoxicity of bulk-fill composite resins.

Authors:  Mohammad Esmaeel Ebrahimi Chaharom; Mahmoud Bahari; Leila Safyari; Hossein Safarvand; Hajar Shafaei; Elmira Jafari Navimipour; Parnian Alizadeh Oskoee; Amir Ahmad Ajami; Mahdi Abed Kahnamouei
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2020

8.  Physical and photoelastic properties of bulk-fill and conventional composites.

Authors:  Renata Pereira; Maria Cecília Caldas Giorgi; Rodrigo Barros Esteves Lins; Jéssica Dias Theobaldo; Débora Alves Nunes Leite Lima; Giselle Maria Marchi; Flávio Henrique Baggio Aguiar
Journal:  Clin Cosmet Investig Dent       Date:  2018-12-12

9.  Simultaneous Evaluation of Creep Deformation and Recovery of Bulk-Fill Dental Composites Immersed in Food-Simulating Liquids.

Authors:  Ali Alrahlah; Rawaiz Khan; Khalid Alotaibi; Ziad Almutawa; H Fouad; Mohamed Elsharawy; Nikolaos Silikas
Journal:  Materials (Basel)       Date:  2018-07-10       Impact factor: 3.623

10.  A Comparative Evaluation of Time-dependent Changes on the Surface Hardness of Bulk Cure Composites: An in vitro Study.

Authors:  Anindita Sarma; Priya Nagar
Journal:  Int J Clin Pediatr Dent       Date:  2018-06-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.