Literature DB >> 32451783

State of the art in total body PET.

Stefaan Vandenberghe1, Pawel Moskal2, Joel S Karp3.   

Abstract

The idea of a very sensitive positron emission tomography (PET) system covering a large portion of the body of a patient already dates back to the early 1990s. In the period 2000-2010, only some prototypes with long axial field of view (FOV) have been built, which never resulted in systems used for clinical research. One of the reasons was the limitations in the available detector technology, which did not yet have sufficient energy resolution, timing resolution or countrate capabilities for fully exploiting the benefits of a long axial FOV design. PET was also not yet as widespread as it is today: the growth in oncology, which has become the major application of PET, appeared only after the introduction of PET-CT (early 2000).The detector technology used in most clinical PET systems today has a combination of good energy and timing resolution with higher countrate capabilities and has now been used since more than a decade to build time-of-flight (TOF) PET systems with fully 3D acquisitions. Based on this technology, one can construct total body PET systems and the remaining challenges (data handling, fast image reconstruction, detector cooling) are mostly related to engineering. The direct benefits of long axial FOV systems are mostly related to the higher sensitivity. For single organ imaging, the gain is close to the point source sensitivity which increases linearly with the axial length until it is limited by solid angle and attenuation of the body. The gains for single organ (compared to a fully 3D PET 20-cm axial FOV) are limited to a factor 3-4. But for long objects (like body scans), it increases quadratically with scanner length and factors of 10-40 × higher sensitivity are predicted for the long axial FOV scanner. This application of PET has seen a major increase (mostly in oncology) during the last 2 decades and is now the main type of study in a PET centre. As the technology is available and the full body concept also seems to match with existing applications, the old concept of a total body PET scanner is seeing a clear revival. Several research groups are working on this concept and after showing the potential via extensive simulations; construction of these systems has started about 2 years ago. In the first phase, two PET systems with long axial FOV suitable for large animal imaging were constructed to explore the potential in more experimental settings. Recently, the first completed total body PET systems for human use, a 70-cm-long system, called PennPET Explorer, and a 2-m-long system, called uExplorer, have become reality and first clinical studies have been shown. These results illustrate the large potential of this concept with regard to low-dose imaging, faster scanning, whole-body dynamic imaging and follow-up of tracers over longer periods. This large range of possible technical improvements seems to have the potential to change the current clinical routine and to expand the number of clinical applications of molecular imaging. The J-PET prototype is a prototype system with a long axial FOV built from axially arranged plastic scintillator strips.This paper gives an overview of the recent technical developments with regard to PET scanners with a long axial FOV covering at least the majority of the body (so called total body PET systems). After explaining the benefits and challenges of total body PET systems, the different total body PET system designs proposed for large animal and clinical imaging are described in detail. The axial length is one of the major factors determining the total cost of the system, but there are also other options in detector technology, design and processing for reducing the cost these systems. The limitations and advantages of different designs for research and clinical use are discussed taking into account potential applications and the increased cost of these systems.

Entities:  

Keywords:  PET; PET-CT; Sensitivity

Year:  2020        PMID: 32451783     DOI: 10.1186/s40658-020-00290-2

Source DB:  PubMed          Journal:  EJNMMI Phys        ISSN: 2197-7364


  21 in total

1.  Clinical perspectives for the use of total body PET/CT.

Authors:  Ronan Abgral; David Bourhis; Pierre-Yves Salaun
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-06       Impact factor: 9.236

Review 2.  [18F]FDG-PET Evaluation of Spinal Pathology in Patients in Oncology: Pearls and Pitfalls for the Neuroradiologist.

Authors:  P Y Patel; I Dalal; B Griffith
Journal:  AJNR Am J Neuroradiol       Date:  2021-10-28       Impact factor: 3.825

3.  An encoder-decoder network for direct image reconstruction on sinograms of a long axial field of view PET.

Authors:  Ruiyao Ma; Jiaxi Hu; Hasan Sari; Song Xue; Clemens Mingels; Marco Viscione; Venkata Sai Sundar Kandarpa; Wei Bo Li; Dimitris Visvikis; Rui Qiu; Axel Rominger; Junli Li; Kuangyu Shi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-07-11       Impact factor: 10.057

Review 4.  Advances in Detector Instrumentation for PET.

Authors:  Andrea Gonzalez-Montoro; Muhammad Nasir Ullah; Craig S Levin
Journal:  J Nucl Med       Date:  2022-08       Impact factor: 11.082

Review 5.  Direct Cell Radiolabeling for in Vivo Cell Tracking with PET and SPECT Imaging.

Authors:  Peter J Gawne; Francis Man; Philip J Blower; Rafael T M de Rosales
Journal:  Chem Rev       Date:  2022-05-12       Impact factor: 72.087

6.  The potential of a medium-cost long axial FOV PET system for nuclear medicine departments.

Authors:  Stefaan Vandenberghe; Nicolas A Karakatsanis; Maya Abi Akl; Jens Maebe; Suleman Surti; Rudi A Dierckx; Daniel A Pryma; Sadek A Nehmeh; Othmane Bouhali; Joel S Karp
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-09-30       Impact factor: 10.057

7.  [18F]FDG-labelled stem cell PET imaging in different route of administrations and multiple animal species.

Authors:  Naoko Nose; Suguru Nogami; Kazuhiro Koshino; Xinyu Chen; Rudolf A Werner; Soki Kashima; Steven P Rowe; Constantin Lapa; Kazuki Fukuchi; Takahiro Higuchi
Journal:  Sci Rep       Date:  2021-05-25       Impact factor: 4.379

Review 8.  Radiation Absorbed Dose to the Embryo and Fetus from Radiopharmaceuticals.

Authors:  Paolo Zanotti-Fregonara
Journal:  Semin Nucl Med       Date:  2022-01-21       Impact factor: 4.446

9.  An international expert opinion statement on the utility of PET/MR for imaging of skeletal metastases.

Authors:  Jad S Husseini; Bárbara Juarez Amorim; Angel Torrado-Carvajal; Vinay Prabhu; David Groshar; Lale Umutlu; Ken Herrmann; Lina García Cañamaque; José Ramón García Garzón; William E Palmer; Pedram Heidari; Tiffany Ting-Fang Shih; Jacob Sosna; Cristina Matushita; Juliano Cerci; Marcelo Queiroz; Valdair Francisco Muglia; Marcello H Nogueira-Barbosa; Ronald J H Borra; Thomas C Kwee; Andor W J M Glaudemans; Laura Evangelista; Marco Salvatore; Alberto Cuocolo; Andrea Soricelli; Christian Herold; Andrea Laghi; Marius Mayerhoefer; Umar Mahmood; Ciprian Catana; Heike E Daldrup-Link; Bruce Rosen; Onofrio A Catalano
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-02-22       Impact factor: 9.236

10.  New PET technologies - embracing progress and pushing the limits.

Authors:  Nicolas Aide; Charline Lasnon; Adam Kesner; Craig S Levin; Irene Buvat; Andrei Iagaru; Ken Hermann; Ramsey D Badawi; Simon R Cherry; Kevin M Bradley; Daniel R McGowan
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-06-03       Impact factor: 9.236

View more