Literature DB >> 32420251

Comparing LigasureTM Exact dissector with other energy devices in total thyroidectomy: a pilot study.

Theodosios S Papavramidis1,2, Ioannis Pliakos1,2, Angeliki Chorti2, Stavros Panidis1,2, George Kotsovolis1, Veronica Stelmach2, Dimitris Koutsoumparis1, Sohail Bakkar3, Antonios Michalopoulos2.   

Abstract

BACKGROUND: Hemostasis is fundamental in thyroid surgery. The aim of this randomized active comparator-controlled study was to compare the effectiveness of LigasureTM Exact to previously existing sealing devices in patients undergoing thyroidectomy.
METHODS: A total of 180 patients were randomly allocated into 4 groups according to the hemostatic device used: Focus Harmonic Scalpel® (FHS), LigasureTM Small Jaw (LSJ), Thunderbeat® (TB), and LigasureTM Exact (LE). We recorded epidemiologic and biochemical data, operative difficulty, postoperative vocal alteration and pain, complications, operating time, grams of gland excised per minute, and hospitalization.
RESULTS: Differences (P<0.001) were observed concerning duration of surgery, operative difficulty and quantity of gland removed per minute. Concerning duration of surgery it is shorter for LE followed by TB and then by both FHS and LSJ. Concerning the quantity of thyroid removed per minute LE leads, followed by FHS and TB. The least amount of gland removed per minute is by LSJ. Finally, operative difficulty was less for LE, while it was equal for all other three devices.
CONCLUSIONS: Energy devices are now frequently used in thyroidectomy. Comparing these devices seems to qualify them as equal concerning post-operative complications, hemostasis, and acute inflammatory reaction. However, LigasureTM Exact Dissector seems to have better results concerning duration of surgery, quantity of thyroid tissue removed per minute and intraoperative difficulty. 2020 Gland Surgery. All rights reserved.

Entities:  

Keywords:  Focus Harmonic Scalpel; Ligasure Exact; Ligasure Small Jaw; Thyroid surgery; thyroidectomy

Year:  2020        PMID: 32420251      PMCID: PMC7225447          DOI: 10.21037/gs.2020.02.05

Source DB:  PubMed          Journal:  Gland Surg        ISSN: 2227-684X


  24 in total

1.  Sutureless thyroidectomy with energy-based devices: Cerrahpasa experience.

Authors:  Serkan Teksoz; Yusuf Bukey; Murat Ozcan; Akif Enes Arikan; Ates Ozyegin
Journal:  Updates Surg       Date:  2013-08-29

2.  Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomy.

Authors:  Andreas Manouras; Emmanuel E Lagoudianakis; Pantelis T Antonakis; George M Filippakis; Haridimos Markogiannakis; Panagiotis B Kekis
Journal:  Head Neck       Date:  2005-11       Impact factor: 3.147

3.  Sutureless thyroidectomy.

Authors:  Roberto Ruggiero; Adelmo Gubitosi; Giovanni Conzo; Simona Gili; Alfonso Bosco; Raffaele Pirozzi; Cosma Cosenza; Gianluca Rossetti; Landino Fei; Giovanni Docimo; Ludovico Docimo
Journal:  Int J Surg       Date:  2014-05-22       Impact factor: 6.071

4.  Risk of Complications with Energy-Based Surgical Devices in Thyroid Surgery: A National Multicenter Register Study.

Authors:  Johan Carlander; Philippe Wagner; Oliver Gimm; Erik Nordenström; Svante Jansson; Leif Bergkvist; Kenth Johansson
Journal:  World J Surg       Date:  2016-01       Impact factor: 3.352

5.  PARATHYROID FUNCTION AFTER TOTAL THYROIDECTOMY: A RANDOMIZED CLINICAL TRIAL CONCERNING THE INFLUENCE OF THE SURGICAL TECHNIQUE.

Authors:  Theodossis S Papavramidis; Olympia Anastasiou; Ioannis Pliakos; George Kotsovolis; Stavros Panidis; Antonios Michalopoulos
Journal:  Endocr Pract       Date:  2017-11-16       Impact factor: 3.443

Review 6.  Neutrophils, host defense, and inflammation: a double-edged sword.

Authors:  J A Smith
Journal:  J Leukoc Biol       Date:  1994-12       Impact factor: 4.962

7.  Incidental parathyroidectomy during thyroid surgery does not cause transient symptomatic hypocalcemia.

Authors:  A R Sasson; J F Pingpank; R W Wetherington; A L Hanlon; J A Ridge
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2001-03

8.  Long-term voice outcome after thyroidectomy using energy based devices.

Authors:  Min Woo Park; Seung-Kuk Baek; Euy-Hyun Park; Kwang-Yoon Jung
Journal:  Auris Nasus Larynx       Date:  2017-08-30       Impact factor: 1.863

9.  Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study.

Authors:  Th Defechereux; F Rinken; S Maweja; E Hamoir; M Meurisse
Journal:  Acta Chir Belg       Date:  2003-06       Impact factor: 1.090

10.  Ligasure versus Ultracision in thyroid surgery: a prospective randomized study.

Authors:  Paola Vincenza Sartori; Sergio De Fina; Giovanni Colombo; Francesco Pugliese; Fabrizio Romano; Giovanni Cesana; Franco Uggeri
Journal:  Langenbecks Arch Surg       Date:  2008-07-22       Impact factor: 3.445

View more
  1 in total

1.  The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center.

Authors:  Gian Luigi Canu; Fabio Medas; Federico Cappellacci; Francesco Casti; Raffaela Bura; Enrico Erdas; Pietro Giorgio Calò
Journal:  J Clin Med       Date:  2022-05-29       Impact factor: 4.964

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.