Literature DB >> 26470699

Risk of Complications with Energy-Based Surgical Devices in Thyroid Surgery: A National Multicenter Register Study.

Johan Carlander, Philippe Wagner, Oliver Gimm, Erik Nordenström, Svante Jansson, Leif Bergkvist, Kenth Johansson.   

Abstract

BACKGROUND: Energy-based surgical devices (EBD) combining cutting and coagulation are increasingly used in thyroid surgery. However, there is a lack of information about potential benefits and risk of complications outside controlled trials. The aims of this national multicenter register study were to describe the use of EDB, their potential effect on complication rates, and on operation time.
MATERIALS AND METHODS: The Scandinavian Quality Register for Thyroid and Parathyroid surgery includes 35 surgical units in Sweden and covered 88% of the thyroid procedures performed during 2008–2009. The use of the EBD was specifically registered for 12 months, and 1297 patients were included. Surgically related complications and operation time were evaluated. The clamp-and-tie group (C-A-T) constituted the control group for comparison with procedures where EBD was used.
RESULTS: The thyroid procedures performed included C-A-T (16.6%), bipolar electrosurgery (ES: 56.5%), electronic vessel sealing (EVS: 12.2%), and ultrasonic dissection (UD: 14.5%). Mean operative time was longer with EVS (p < 0.001) and shorter with UD (p < 0.05) than in the other groups. The bipolar ES group and the EVS group had higher incidence of calcium treatment at discharge and after 6 weeks than the UD group. No significant difference in nerve injury was found between the groups. There was a significant more frequent use of topical hemostatic agents in the EBD group compared to C-A-T.
CONCLUSION: In this national multicenter study, the use of UD shortened and EVS increased operating time. There was a higher risk of calcium treatment at discharge and after 6 weeks after use of EVS and bipolar ES than after UD use. There was a significant more frequent use of topical hemostatic agents in the EBD groups compared to C-A-T.

Entities:  

Mesh:

Year:  2016        PMID: 26470699     DOI: 10.1007/s00268-015-3270-7

Source DB:  PubMed          Journal:  World J Surg        ISSN: 0364-2313            Impact factor:   3.352


  22 in total

1.  Sutureless thyroidectomy with energy-based devices: Cerrahpasa experience.

Authors:  Serkan Teksoz; Yusuf Bukey; Murat Ozcan; Akif Enes Arikan; Ates Ozyegin
Journal:  Updates Surg       Date:  2013-08-29

2.  Comparison of experimental nerve injury caused by ultrasonically activated scalpel and electrosurgery.

Authors:  J Carlander; K Johansson; S Lindström; A K Velin; C H Jiang; C Nordborg
Journal:  Br J Surg       Date:  2005-06       Impact factor: 6.939

3.  Complications to thyroid surgery: results as reported in a database from a multicenter audit comprising 3,660 patients.

Authors:  A Bergenfelz; S Jansson; A Kristoffersson; H Mårtensson; E Reihnér; G Wallin; I Lausen
Journal:  Langenbecks Arch Surg       Date:  2008-07-17       Impact factor: 3.445

Review 4.  ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery--the ENERCON systematic review and network meta-analysis.

Authors:  Pietro Contin; Käthe Gooßen; Kathrin Grummich; Katrin Jensen; Hubertus Schmitz-Winnenthal; Markus W Büchler; Markus K Diener
Journal:  Langenbecks Arch Surg       Date:  2013-11-16       Impact factor: 3.445

5.  Risk factors for medically treated hypocalcemia after surgery for Graves' disease: a Swedish multicenter study of 1,157 patients.

Authors:  P Hallgrimsson; E Nordenström; M Almquist; A O J Bergenfelz
Journal:  World J Surg       Date:  2012-08       Impact factor: 3.352

6.  Randomized controlled trial of harmonic scalpel use during thyroidectomy.

Authors:  Paolo Miccoli; Piero Berti; Gianlorenzo Dionigi; Gian L Dionigi; Jacopo D'Agostino; Cinzia Orlandini; Gianluca Donatini
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2006-10

7.  Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy.

Authors:  Yoann Pons; Jérome Gauthier; Elsa Ukkola-Pons; Philippe Clément; Eric Roguet; Jean-Luc Poncet; Claude Conessa
Journal:  Otolaryngol Head Neck Surg       Date:  2009-10       Impact factor: 3.497

8.  Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure) versus conventional clamp-and-tie technique.

Authors:  Jan Franko; Karen J Kish; Christopher M Pezzi; Ho Pak; John S Kukora
Journal:  Am Surg       Date:  2006-02       Impact factor: 0.688

9.  LigaSure versus clamp-and-tie thyroidectomy for benign nodular disease.

Authors:  Ioannis E Petrakis; Nektarios E Kogerakis; Kostas G Lasithiotakis; Nikolaos Vrachassotakis; Georgios E Chalkiadakis
Journal:  Head Neck       Date:  2004-10       Impact factor: 3.147

Review 10.  Common uses and cited complications of energy in surgery.

Authors:  Ganesh Sankaranarayanan; Rajeswara R Resapu; Daniel B Jones; Steven Schwaitzberg; Suvranu De
Journal:  Surg Endosc       Date:  2013-04-23       Impact factor: 4.584

View more
  3 in total

Review 1.  Energy-based devices in thyroid surgery-an overview.

Authors:  Sohail Bakkar; Theodosios S Papavramidis; Qusai Aljarrah; Gabriele Materazzi; Paolo Miccoli
Journal:  Gland Surg       Date:  2020-01

2.  The Effect of Energy Devices, Nerve Monitors, and Drains on Thyroidectomy Outcomes: An American College of Surgeons National Surgical Quality Improvement Project Database Analysis.

Authors:  John D Vossler; Kameko M Karasaki; Reid C Mahoney; Stacey L Woodruff; Kenric M Murayama
Journal:  Hawaii J Health Soc Welf       Date:  2021-11

3.  Comparing LigasureTM Exact dissector with other energy devices in total thyroidectomy: a pilot study.

Authors:  Theodosios S Papavramidis; Ioannis Pliakos; Angeliki Chorti; Stavros Panidis; George Kotsovolis; Veronica Stelmach; Dimitris Koutsoumparis; Sohail Bakkar; Antonios Michalopoulos
Journal:  Gland Surg       Date:  2020-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.