Literature DB >> 18648850

Ligasure versus Ultracision in thyroid surgery: a prospective randomized study.

Paola Vincenza Sartori1, Sergio De Fina, Giovanni Colombo, Francesco Pugliese, Fabrizio Romano, Giovanni Cesana, Franco Uggeri.   

Abstract

PURPOSE: New hemostatic technologies (NT) are often employed in thyroid surgery in the effort to reduce operating time and complications. The aim of this study is to compare three different hemostatic techniques.
METHODS: This is a prospective randomized study. There were 150 patients, aged 56 +/- 14 years, randomized for total thyroidectomy with conventional technique (CT), Ligasure vessel sealing system (LI) or Harmonic Scalpel (HS) at the university surgical department. One hundred thirty-five patients had benign diseases; 15 had malignancies.
RESULTS: Mean postoperative hospital stay was 2.6 days. Mean operation time was 113 +/- 31 min; in HS patients, it was significantly shorter (p < 0.001). Morbidity was 43.3%; mortality was nil. Morbidity was significantly different between CT and NT groups (p = 0.0002); HS and LI groups had a higher morbidity (p = 0.0001 and p = 0.02, respectively). Mean postoperative calcemia was 1.12 +/- 0.1 mmol/l with a significant difference between groups; NT patients had a significantly lower calcemia (p < 0.05). There was no difference in recurrent laryngeal nerve palsies and in intraoperative blood losses (p = ns).
CONCLUSIONS: According to our experience, the only real advantage of new hemostatic technologies was a shorter operation time with HS.

Entities:  

Mesh:

Year:  2008        PMID: 18648850     DOI: 10.1007/s00423-008-0386-3

Source DB:  PubMed          Journal:  Langenbecks Arch Surg        ISSN: 1435-2443            Impact factor:   3.445


  15 in total

1.  Ultrasonically activated shears in thyroidectomies: a randomized trial.

Authors:  P E Voutilainen; C H Haglund
Journal:  Ann Surg       Date:  2000-03       Impact factor: 12.969

2.  A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy.

Authors:  Carlos Cordón; Rafael Fajardo; Jaqueline Ramírez; Miguel F Herrera
Journal:  Surgery       Date:  2005-03       Impact factor: 3.982

3.  [Ultrasonic dissectors in endoscopic surgery].

Authors:  D Gossot
Journal:  Ann Chir       Date:  1998

4.  The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery.

Authors:  Allan E Siperstein; Eren Berber; Ebru Morkoyun
Journal:  Arch Surg       Date:  2002-02

5.  Randomized controlled trial of harmonic scalpel use during thyroidectomy.

Authors:  Paolo Miccoli; Piero Berti; Gianlorenzo Dionigi; Gian L Dionigi; Jacopo D'Agostino; Cinzia Orlandini; Gianluca Donatini
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2006-10

6.  Tissue effects of an ultrasonic scalpel for clinical surgical use.

Authors:  S A Boddy; J W Ramsay; S S Carter; P J Webster; D A Levison; H N Whitfield
Journal:  Urol Res       Date:  1987

7.  Use of a diathermy system in thyroid surgery.

Authors:  Andreas Kiriakopoulos; Tsakayannis Dimitrios; Linos Dimitrios
Journal:  Arch Surg       Date:  2004-09

8.  Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study.

Authors:  Th Defechereux; F Rinken; S Maweja; E Hamoir; M Meurisse
Journal:  Acta Chir Belg       Date:  2003-06       Impact factor: 1.090

9.  Complications of thyroid surgery: analysis of a multicentric study on 14,934 patients operated on in Italy over 5 years.

Authors:  Lodovico Rosato; Nicola Avenia; Paolo Bernante; Maurizio De Palma; Giuseppe Gulino; Pier Giorgio Nasi; Maria Rosa Pelizzo; Luciano Pezzullo
Journal:  World J Surg       Date:  2004-02-17       Impact factor: 3.352

10.  Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation.

Authors:  Andreas Manouras; Haridimos Markogiannakis; Athanasios S Koutras; Pantelis T Antonakis; Panagiotis Drimousis; Emmanuel E Lagoudianakis; Panagiotis Kekis; Michael Genetzakis; Konstantinos Koutsoumanis; Ioannis Bramis
Journal:  Am J Surg       Date:  2008-01       Impact factor: 2.565

View more
  29 in total

1.  Short-stay hospitalisation for benign thyroid surgery: a prospective study.

Authors:  Fausto Fama'; Cecile Linard; Rosalia Patti; Miles G Berry; Maria Gioffre'-Florio; Arnaud Piquard; Olivier Saint-Marc
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-06-13       Impact factor: 2.503

2.  Vascular clips versus ligatures in thyroid surgery--results of a multicenter randomized controlled trial (CLIVIT Trial).

Authors:  Markus K Diener; Christoph M Seiler; Moritz von Frankenberg; Kathleen Rendel; Silke Schüle; Katja Maschuw; Stefan Riedl; Jens C Rückert; Christian Eckmann; Uwe Scharlau; Alexis Ulrich; Thomas Bruckner; Hanns-Peter Knaebel; Matthias Rothmund; Markus W Büchler
Journal:  Langenbecks Arch Surg       Date:  2012-06-24       Impact factor: 3.445

Review 3.  Surgical Efficacy Among Laparoscopic Ultrasonic Dissectors: Are We Advancing Safely? A Review of Literature.

Authors:  Rajesh Devassy; Sreelatha Gopalakrishnan; Rudy Leon De Wilde
Journal:  J Obstet Gynaecol India       Date:  2015-09-14

4.  Sutureless thyroidectomy with energy-based devices: Cerrahpasa experience.

Authors:  Serkan Teksoz; Yusuf Bukey; Murat Ozcan; Akif Enes Arikan; Ates Ozyegin
Journal:  Updates Surg       Date:  2013-08-29

5.  Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments.

Authors:  Gianlorenzo Dionigi
Journal:  Langenbecks Arch Surg       Date:  2008-12-24       Impact factor: 3.445

6.  Thyroid surgery with harmonic focus, ligasure precise and conventional technique: a retrospective case-matched study.

Authors:  A Bove; Ig Papanikolaou; G Bongarzoni; Pa Mattei; H Markogiannakis; M Chatzipetrou; V D'Addetta; Rm Di Renzo; M Fiordaliso; L Corbellini
Journal:  Hippokratia       Date:  2012-04       Impact factor: 0.471

Review 7.  ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery--the ENERCON systematic review and network meta-analysis.

Authors:  Pietro Contin; Käthe Gooßen; Kathrin Grummich; Katrin Jensen; Hubertus Schmitz-Winnenthal; Markus W Büchler; Markus K Diener
Journal:  Langenbecks Arch Surg       Date:  2013-11-16       Impact factor: 3.445

8.  Bipolar thermofusion vessel sealing system (TVS) versus conventional vessel ligation (CVL) in thyroid surgery--results of a prospective study.

Authors:  Pier Francesco Alesina; Thomas Rolfs; Martin K Walz
Journal:  Langenbecks Arch Surg       Date:  2010-02       Impact factor: 3.445

9.  Thyroidectomy with LigaSure.

Authors:  Mile Ignjatović; Zoran Kostić
Journal:  Surg Today       Date:  2011-05-28       Impact factor: 2.549

10.  Update on sutureless thyroidectomy.

Authors:  R Ruggiero; G Docimo; A Bosco; M Lanza Volpe; G Terracciano; A Gubitosi; L Docimo
Journal:  G Chir       Date:  2018 Jan-Feb
View more