Literature DB >> 3240076

Reactions of surrounding tissue to the cementless hip implant Ti-6Al-4V after an implantation period of several years. Autopsy studies in three cases.

F Lintner1, K Zweymüller, G Böhm, G Brand.   

Abstract

Three femoral endoprosthetic stems implanted without cement, made of Ti-6Al-4V alloy, with implantation periods of between 2 and 4 years were examined histologically in the form of undecalcified thin ground sections after having been split into segments and embedded in plastic. During the implantation period total osseointegration in the metadiaphyseal region takes place, while in the proximal area reaction forms with direct contact between metal and bone on the one hand and with an interposed membrane of connective tissue and adjacent secondary bony shell on the other must be distinguished. The osseointegration of the stem is the result of a primary healing of the bone and is due to the biocompatibility of the metal alloy and to the primary stability obtained by the press-fit method.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3240076     DOI: 10.1007/bf00381062

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  7 in total

1.  A cementless titanium hip endoprosthesis system based on press-fit fixation: basic research and clinical results.

Authors:  K Zweymüller
Journal:  Instr Course Lect       Date:  1986

2.  [The effect of aging on endoprostheses].

Authors:  G Aldinger; K Mitzkat
Journal:  Z Orthop Ihre Grenzgeb       Date:  1986 Jul-Aug

3.  Tissue reactions to titanium endoprostheses. Autopsy studies in four cases.

Authors:  F Lintner; K Zweymüller; G Brand
Journal:  J Arthroplasty       Date:  1986       Impact factor: 4.757

4.  The diagnostic value of the new method for the study of undecalcified bones and teeth with attached soft tissue (Säge-Schliff (sawing and grinding) technique).

Authors:  K Donath
Journal:  Pathol Res Pract       Date:  1985-05       Impact factor: 3.250

5.  [Histological examinations of remodelling proceedings on the cement-bone surface of endoprosthesis after implantation from 3-10 years ].

Authors:  F Lintner; P Bösch; G Brand
Journal:  Pathol Res Pract       Date:  1982       Impact factor: 3.250

6.  Concept and material properties of a cementless hip prosthesis system with Al2O3 ceramic ball heads and wrought Ti-6Al-4V stems.

Authors:  K Zweymüller; M Semlitsch
Journal:  Arch Orthop Trauma Surg       Date:  1982

7.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981
  7 in total
  4 in total

1.  Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

Authors:  M Viceconti; A Pancanti; M Dotti; F Traina; L Cristofolini
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

2.  Evaluation of peri-prosthetic radiolucent lines surrounding the cementless femoral stem using digital tomosynthesis with metal artifact reduction: a cadaveric study in comparison with radiography and computed tomography.

Authors:  Hao Tang; Xingjian Huang; Xiaoguang Cheng; Dejin Yang; Yong Huang; Yixin Zhou
Journal:  Quant Imaging Med Surg       Date:  2020-09

3.  Genetic diversity and population structure of early and extra-early maturing maize germplasm adapted to sub-Saharan Africa.

Authors:  Baffour Badu-Apraku; Ana Luísa Garcia-Oliveira; César Daniel Petroli; Sarah Hearne; Samuel Adeyemi Adewale; Melaku Gedil
Journal:  BMC Plant Biol       Date:  2021-02-17       Impact factor: 4.215

4.  Late removal of titanium hardware from the elbow is problematic.

Authors:  Abdo Bachoura; Ruriko Yoshida; Christian Lattermann; Srinath Kamineni
Journal:  ISRN Orthop       Date:  2012-02-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.