Pier Luigi Ingrassia1, Giulia Mormando2, Eleonora Giudici3, Francesco Strada4, Fabio Carfagna1, Fabrizio Lamberti4, Andrea Bottino4.
Abstract
BACKGROUND: Basic life support (BLS) is crucial in the emergency response system, as sudden cardiac arrest is still a major cause of death worldwide. Unfortunately, only a minority of victims receive cardiopulmonary resuscitation (CPR) from bystanders. In this context, training could be helpful to save more lives, and technology-enhanced BLS simulation is one possible solution.Entities:
Keywords: augmented reality; automated external defibrillators; cardiopulmonary resuscitation
Year: 2020 PMID: 32396128 PMCID: PMC7251481 DOI: 10.2196/14910
Source DB: PubMed Journal: J Med Internet Res ISSN: 1438-8871 Impact factor: 5.428
Figure 1A trainee using the HoloLens device (above) and AR displayed in the trainee’s field of view (below).
Respondents’ demographics and characteristicsa.
| Characteristic | Participants, n (%) | ||
|
| |||
|
| Male | 16 (62) | |
|
| Female | 10 (38) | |
|
| |||
|
| 20-29 | 15 (58) | |
|
| 30-39 | 9 (35) | |
|
| 40-49 | 0 (0) | |
|
| 50-59 | 2 (8) | |
|
| |||
|
| Resident | 19 (73) | |
|
| Physician | 3 (12) | |
|
| Nurse | 1 (4) | |
|
|
|
| |
|
|
| Space system engineer | 1 (4) |
|
|
| Designer | 1 (4) |
|
|
| Secretary | 1 (4) |
|
| |||
|
| Emergency medicine | 7 (32) | |
|
| Anesthesiology | 6 (27) | |
|
| General surgery | 2 (9) | |
|
| Internal medicine | 1 (5) | |
|
| Pediatrics | 1 (5) | |
|
| Cardiology | 1 (5) | |
|
| Not specified | 4 (18) | |
aPercentages may not add up to 100 due to rounding.
bOnly applicable to residents and physicians.
Aggregated data for the system usability scale.
|
| Question | Strongly Disagree (%) | Disagree (%) | Neither (%) | Agree (%) | Strongly Agree (%) | Mean (SD) |
|
| |||||||
|
| I think that I would like to use this system frequently | 0.0 | 11.5 | 23.1 | 38.5 | 26.9 | 3.81 (0.98) |
| I found the system unnecessarily complex | 48.0 | 36.0 | 12.0 | 4.0 | 0.0 | 1.72 (0.84) | |
| I thought the system was easy to use | 0.0 | 7.7 | 19.2 | 38.5 | 34.6 | 4.00 (0.94) | |
| I think that I would need the support of a technical person to be able to use this system | 15.4 | 19.2 | 30.8 | 23.1 | 11.5 | 2.96 (1.25) | |
| I found the various functions in this system were well integrated | 0.0 | 3.8 | 30.8 | 42.3 | 23.1 | 3.85 (0.83) | |
| I thought there was too much inconsistency in this system | 26.9 | 34.6 | 23.1 | 11.5 | 3.8 | 2.31 (1.12) | |
| I would imagine that most people would learn to use this system very quickly | 0.0 | 3.8 | 26.9 | 34.6 | 34.6 | 4.00 (0.89) | |
| I found the system very cumbersome to use | 32.0 | 24.0 | 28.0 | 8.0 | 8.0 | 2.36 (1.25) | |
| I felt very confident using the system | 0.0 | 23.1 | 11.5 | 46.2 | 19.2 | 3.62 (1.06) | |
| I needed to learn a lot of things before I could get going with this system | 57.7 | 26.9 | 11.5 | 0.0 | 3.8 | 1.65 (0.98) | |
|
| |||||||
|
| The HoloLens device is too bulky or too heavy | 19.2 | 42.3 | 3.8 | 26.9 | 7.7 | 2.62 (1.30) |
| The mental effort (concentration) required to operate the device was very high | 46.2 | 34.6 | 15.4 | 3.8 | 0.0 | 1.77 (0.86) | |
| The physical effort required to operate the device was very high | 80.8 | 19.2 | 0.0 | 0.0 | 0.0 | 1.19 (0.40) | |
| Arm and hands/fingers fatigue was very high | 76.9 | 19.2 | 3.8 | 0.0 | 0.0 | 1.27 (0.53) | |
| Eye fatigue was very high | 42.3 | 23.1 | 19.2 | 7.7 | 7.7 | 2.15 (1.29) | |
| Head fatigue was very high | 38.5 | 38.5 | 15.4 | 0.0 | 7.7 | 2.00 (1.13) | |
| I would be comfortable using the device for long time | 15.4 | 15.4 | 30.8 | 34.6 | 3.8 | 2.96 (1.15) | |