Literature DB >> 32351313

Ion trap operational modes for ion/ion reactions yielding high mass-to-charge product ions.

Kenneth W Lee1, Gregory S Eakins1, Mark S Carlsen1, Scott A McLuckey1.   

Abstract

To better probe large biomolecular complexes, developments in mass spectrometry (MS) have focused on improving technologies used to generate, transmit, and measure high m/z ions. The additional tandem-MS (MSn) capabilities of ion trap mass spectrometers (ITMS) facilitate experiments that facilitate probing complex biomolecular ions. In particular, charge reduction using gas-phase ion/ion reactions increase separation of charge states generated via electrospray ionization (ESI), which increases confidence in charge state assignments and therefore masses determined from the observed charge states. Current ITMS technologies struggle to generate and measure low charge states of large (>50 kDa) proteins and complexes because of power limitations associated with conventional high-frequency sine wave operation. Other approaches, including frequency scanning techniques and use of digital waveforms, reduce or eliminate some of these limitations. The work presented here studies five different operational modes for a quadrupole ion trap (QIT) mass spectrometer used to generate and measure low charge states of bovine serum albumin (BSA), pyruvate kinase (PK), and GroEL. While digital operation of a QIT presents limitations during the ion/ion reaction period of the experiment, it generally provided the best spectra in terms of resolution and signal at m/z > 50,000.

Entities:  

Keywords:  Digital ion trap; High mass ion; Ion/ion reactions; Quadrupole ion trap

Year:  2020        PMID: 32351313      PMCID: PMC7189770          DOI: 10.1016/j.ijms.2020.116313

Source DB:  PubMed          Journal:  Int J Mass Spectrom        ISSN: 1387-3806            Impact factor:   1.986


  16 in total

Review 1.  Ion/ion chemistry of high-mass multiply charged ions.

Authors:  S A McLuckey; J L Stephenson
Journal:  Mass Spectrom Rev       Date:  1998 Nov-Dec       Impact factor: 10.946

2.  A digital ion trap mass spectrometer coupled with atmospheric pressure ion sources.

Authors:  Li Ding; Michael Sudakov; Francesco L Brancia; Roger Giles; Sumio Kumashiro
Journal:  J Mass Spectrom       Date:  2004-05       Impact factor: 1.982

3.  Implementation of ion/ion reactions in a quadrupole/time-of-flight tandem mass spectrometer.

Authors:  Yu Xia; Paul A Chrisman; David E Erickson; Jian Liu; Xiaorong Liang; Frank A Londry; Min J Yang; Scott A McLuckey
Journal:  Anal Chem       Date:  2006-06-15       Impact factor: 6.986

4.  High resolution on a quadrupole ion trap mass spectrometer.

Authors:  J C Schwartz; J E Syka; I Jardine
Journal:  J Am Soc Mass Spectrom       Date:  1991-05       Impact factor: 3.109

5.  Simplification of product ion spectra derived from multiply charged parent ions via ion/ion chemistry.

Authors:  J L Stephenson; S A McLuckey
Journal:  Anal Chem       Date:  1998-09-01       Impact factor: 6.986

6.  Experimental Characterization of Secular Frequency Scanning in Ion Trap Mass Spectrometers.

Authors:  Dalton T Snyder; Christopher J Pulliam; Joshua S Wiley; Jason Duncan; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-31       Impact factor: 3.109

7.  Linear mass scans in quadrupole ion traps using the inverse Mathieu q scan.

Authors:  Dalton T Snyder; Christopher J Pulliam; R Graham Cooks
Journal:  Rapid Commun Mass Spectrom       Date:  2016-11-30       Impact factor: 2.419

Review 8.  Electrospray ionization for mass spectrometry of large biomolecules.

Authors:  J B Fenn; M Mann; C K Meng; S F Wong; C M Whitehouse
Journal:  Science       Date:  1989-10-06       Impact factor: 47.728

9.  Digital Waveform Technology and the Next Generation of Mass Spectrometers.

Authors:  Nathan M Hoffman; Zachary P Gotlib; Bojana Opačić; Adam P Huntley; Ashley M Moon; Katherine E G Donahoe; Gregory F Brabeck; Peter T A Reilly
Journal:  J Am Soc Mass Spectrom       Date:  2017-10-02       Impact factor: 3.109

10.  Increasing the Upper Mass/Charge Limit of a Quadrupole Ion Trap for Ion/Ion Reaction Product Analysis via Waveform Switching.

Authors:  Kenneth W Lee; Gregory S Eakins; Mark S Carlsen; Scott A McLuckey
Journal:  J Am Soc Mass Spectrom       Date:  2019-03-14       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.