| Literature DB >> 32351151 |
Yao Lu1, Teng Ma1, Cheng Ren1, Zhong Li1, Liang Sun1, Hanzhong Xue1, Ming Li1, Kun Zhang1, Congming Zhang1, Qian Wang1.
Abstract
OBJECTIVE: To evaluate the effectiveness of bone transport involving circular external fixation and locking plate application for the treatment of segmental tibial defects.Entities:
Keywords: Segmental tibial defects; bone defects; bone transport; circular external fixation; locking plate; orthopedic surgeon; tibia
Mesh:
Year: 2020 PMID: 32351151 PMCID: PMC7218946 DOI: 10.1177/0300060520920407
Source DB: PubMed Journal: J Int Med Res ISSN: 0300-0605 Impact factor: 1.573
Demographic data are summarized.
| Patient | Sex | Age (years) | Defect | External fixationType | Previous surgeries | ||
|---|---|---|---|---|---|---|---|
| Cause | Location | Size (cm) | |||||
| 1 | M | 38 | Nonunion | Middle | 4 | Ring | 2 |
| 2 | M | 56 | Open fracture | Middle | 7.5 | Ring | 3 |
| 3 | F | 46 | Nonunion | Distal | 6.3 | Ring | 1 |
| 4 | M | 32 | Open fracture | Distal | 8.2 | Ring | 3 |
| 5 | M | 20 | Open fracture | Distal | 9.2 | Ring | 2 |
| 6 | M | 61 | Nonunion | Middle | 5.4 | Ring | 3 |
| 7 | M | 42 | Open fracture | Distal | 5.8 | Ring | 2 |
| 8 | M | 47 | Open fracture | Distal | 5.4 | Ring | 3 |
| 9 | F | 55 | Open fracture | Distal | 6.5 | Ring | 1 |
| 10 | M | 65 | Open fracture | Distal | 8.6 | Ring | 5 |
| 11 | M | 38 | Open fracture | Distal | 7.2 | Ring | 3 |
| 12 | M | 40 | Open fracture | Middle | 6.7 | Ring | 2 |
Figure 1.Radiographs and photographs of a 47-year-old male patient (no. 8 in Table 1). (a) Before treatment, showing a 5.4-cm segmental tibial defect. (b) After placement of a laterally-based, 4.5-mm locking plate, showing a ring external fixator applied for bone transport. (c) After docking of the transport segment was achieved (after 64 days of transport). (d) After removal of the fixator on day 64, showing two percutaneous screws fixed at the transported segment. (e, f) Anteroposterior and lateral views after 9 months showing satisfactory union achieved at the distraction callus and docking site.
Follow-up results.
| Patients | EFT | EFI | HI | Alignment | Follow-up | Union | SF-36 | Results | |
|---|---|---|---|---|---|---|---|---|---|
| days | days/cm | day/cm | (°) | (months) | (days) | Bone | Functional | ||
| 1 | 62 | 15.5 | 45.5 | 5 | 12 | 182 | 96 | Excellent | Excellent |
| 2 | 118 | 15.7 | 41.3 | 3 | 18 | 310 | 82 | Excellent | Excellent |
| 3 | 92 | 14.6 | 43.6 | 3 | 18 | 275 | 91 | Excellent | Excellent |
| 4 | 136 | 16.6 | 46.3 | 2 | 20 | 380 | 93 | Excellent | Excellent |
| 5 | 157 | 17.1 | 40 | 2 | 24 | 368 | 92 | Excellent | Excellent |
| 6 | 120 | 22.2 | 50.9 | 1 | 24 | 275 | 90 | Excellent | Excellent |
| 7 | 95 | 16.4 | 56 | 1 | 36 | 325 | 95 | Excellent | Good |
| 8 | 140 | 21.5 | 53.7 | 4 | 36 | 290 | 92 | Excellent | Good |
| 9 | 87 | 12.1 | 39.1 | 5 | 12 | 254 | 89 | Excellent | Excellent |
| 10 | 135 | 15.7 | 45.9 | 4 | 14 | 395 | 92 | Excellent | Excellent |
| 11 | 125 | 17.4 | 39.1 | 4 | 48 | 282 | 93 | Excellent | Good |
| 12 | 90 | 13.4 | 38.5 | 3 | 48 | 258 | 89 | Excellent | Good |
| Mean | 112.1 ± 27.5 | 16.5 ± 2.9 | 44.9 ± 5.9 | 3.1 ± 1.4 | 25.8 ± 13.3 | 299.5 ± 60.5 | 92 ± 2.1 | ||
EFT: external fixation time.
EFI: external fixation index.
HI: healing index.