Pegah Sarraf1, Nazanin Kiomarsi2, Farrokh Haj Taheri3, Behrang Moghaddamzade4, Fatemeh Dibaji1, Mohammad Javad Kharazifard5. 1. Department of Endodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran. 2. Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran. 3. Private Practice, Tehran, Iran. 4. Department of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran. 5. Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
Elimination of microorganisms from the pulp and periapical region through root canal cleaning and shaping is among the most important goals of endodontic treatment [1]. Root canal shaping is a key step in root canal treatment; if performed perfectly, it leads to a favorable prognosis. Cleaning and shaping of the root canal system should provide a conical shape with a consistent taper from the crown to the apex while preserving the original path of the canal [1]. Also, the size of the apical foramen must remain as small as possible [1,2]. However, procedural errors such as ledge formation, zipping, perforation or canal transportation may occur during root canal preparation, especially in curved canals [3].Irrespective of the techniques and instruments used, the cleaning and shaping process of the root canal system continuously removes dentin from the root canal wall. Excessive removal of intracanal dentin in a single direction (instead of equal dentin removal in all directions) leads to canal transportation [4]. Canal transportation is the result of displacement of the physiologic apex to a new position on the external root surface by clinicians [5-8]. These changes may negatively affect the quality of endodontic treatment by lowering the efficiency of disinfection [9-12].During root canal preparation, instruments must remain at the center of root canal space in order not to undermine or excessively weaken the tooth structure; this is referred to as the centering ability of the instruments [13]. By the introduction of new instruments made of nickel-titanium (NiTi) alloy, great advances were made in root canal shaping since NiTi instruments have higher flexibility and shear strength, yielding predictable results. These instruments decrease dentist-related errors even in severely curved canals [13]. On the other hand, NiTi rotary files apply less lateral forces to dentinal walls in curved canals due to having a lower modulus of elasticity than stainless steel (SS) instruments [11]. HyFlex CM (HCM) files, compared to other conventional NiTi files, comprise a lower weight percentage of Ni [14]. The reduction in Ni content decreases the toughness of the alloy. This softer alloy has less tendency to remove dentin and remains at the center of the canal path during root canal preparation [15]. A particular technique with a specific thermal sequence is used in the manufacturing process of these files (patent pendency). This specific thermal sequence increases the fatigue resistance of NiTi alloys [14]. The manufacturer claims that due to the increased flexibility of HCM, this file is the best option for preparation of curved canals compared to conventional files [14]. Edge Taper Platinum (ETP) files are newly introduced files that have the properties of heated NiTi files with characteristics similar to those of ProTaper Gold files [15]. The manufacturer claims that the cyclic fatigue of these files at a certain torque and speed is twice that of ProTaper Gold and six times that of ProTaper Universal files [15].Computed tomographic (CT) scans are among the commonly used conventional methods to assess changes in the root canal system that occur during cleaning and shaping and to evaluate the shaping ability of endodontic rotary files. Cone-beam computed tomography (CBCT) is highly accurate compared to conventional imaging techniques and provides images of different sections [16].Since no previous study has evaluated the efficacy of the ETP rotary system in root canal shaping, this study aimed to assess the efficacy of ETP and HCM rotary files in root canal preparation in comparison with hand files by measuring canal transportation using CBCT.
MATERIALS AND METHODS
Forty-eight maxillary first molars, extracted for periodontal disease or severe caries, were chosen for this study. All teeth had mature apices and non-calcified mesiobuccal canals, confirmed by periapical radiography. Canal curvature was determined on periapical radiographs using Schneider’s method [17]. AutoCAD 2008 (Auto Desk Inc., Mill Valley, CA, USA) was used to calculate the curvature radius according to a method described by Estrela et al [18]. The teeth with 20° to 45° curvatures and 4-mm curvature radius were selected for root canal preparation.
Sample preparation:
The teeth were immersed in 0.5% chloramine-T solution for 24 hours for disinfection. If needed, the crowns were cut to standardize the teeth to have an 18-mm root length. The teeth were then randomly divided into three groups. To standardize the conditions for taking radiographs, the teeth were mounted in acrylic blocks. Before root canal preparation, high-resolution three-dimensional (3D) CBCT scans were obtained using the NewTom Giano system (NewTom, Verona, Italy) with 0.2-mm slice thickness and 11×8-mm2 field of view (FOV) in the axial plane.An access cavity was then prepared, and a #10 K-file (Dentsply Maillefer, Ballaigues, Switzerland) was introduced into the root canal with minimal pressure to ensure patency. The working length was determined by introducing a K-file into the canal until its tip was visible at the apex. One millimeter was subtracted from this length to determine the working length.In group 1 (n=16), the canals were prepared using the HCM system (Coltene, Whaledent, OH, USA). First, a straight path was achieved in the mesiobuccal canal using #10, #15, and #20 K-files (Dentsply Maillefer, Ballaigues, Switzerland) followed by HCM rotary file and rotary handpiece (MORITA Tri Auto Mini, Morita, USA) at 500 revolutions per minute (rpm) and 2.4-N/cm torque. Using the crown-down technique, first, #25/0.08 was used for flaring of the root canal orifice. Next, #30/0.04 and then #30/0.06 were used 3–5 mm shorter of the working length. Next, #25/0.04 and #25/0.06 were used to the working length. Finally, #30/0.04 and then #30/0.06 were used to the working length for shaping of the apical region. After using each rotary file, a hand K-file was used to maintain the patency of the canal.In group two (n=16), the canals were prepared using The ETP system (EdgeEndo, Albuquerque, NM, USA). First, a straight path was achieved in the mesiobuccal canal using a #15 K-file and ETP file and rotary handpiece (MORITA Tri Auto Mini, Morita, USA) at 300 rpm and 4-N/cm torque. First, the Sx file (#19/0.06) was introduced into the canal to the working length followed by the S1 (#18). The S2 file (#20/0.06) was introduced into the canal to the working length. Next, the F1 file (#20/0.06) was used to the working length. The F2 file (#25/0.06) was used for preparation of the apical region. Finally, the F3 file (#30/0.06) was used to accomplish root canal preparation. A hand K-file was used to maintain the patency.In group 3 (n=16), the canals were prepared using SS hand K-files (Dentsply Maillefer, Ballaigues, Switzerland) with the following sequence: #10, #15, #20, #25, and #30. Root canals were prepared using the standard technique followed by the step-back technique to file #60. Root canals were rinsed with 3 ml of 2.5% sodium hypochlorite (NaOCl; Cerkamed, Nisko, Poland) between files. After completion of root canal preparation, the canals were irrigated with 5 ml of 17% ethylenediaminetetraacetic acid (EDTA; Master-Dent, Dentonics, Inc. USA) for one minute, 3 ml of 2.5% NaOCl, and 5 ml of saline as the final rinse. After root canal preparation, CBCT scans were taken again and measurements were made at 0, 3, 6, and 9 mm from the apex using NNT Viewer software (NewTom, Verona, Italy).
Calculation of the amount of canal transportation:
The following formula, introduced by Gambill et al [19], was used for the calculation of the amount of canal transportation (Fig. 1): (A1– A2)–(B1–B2), where A1 is the smallest distance between the external root surface and the external mesial surface of an unprepared root canal, B1 is the smallest distance between the external root surface and the external distal surface of an unprepared root canal, A2 is the smallest distance between the external root surface and the external mesial surface of a prepared root canal, and B2 is the smallest distance between the external root surface and the external distal surface of a prepared root canal [19]. An oral and maxillofacial radiologist made the measurements. The data were analyzed using SPSS software (SPSS Inc., Chicago, IL, USA). The values were placed in the above-mentioned formula. If the result was zero, it indicated no transportation. Any value other than zero indicated canal transportation. The results were analyzed using Kruskal-Wallis and Mann-Whitney tests.
Fig. 1:
The schematic cone-beam computed tomographic axial view of the root canal before and after preparation
The schematic cone-beam computed tomographic axial view of the root canal before and after preparation
RESULTS
The results showed no significant difference among the three groups at 3 mm from the apex (P=0.3). However, the amount of canal transportation among the three groups was significantly different at 0, 6, and 9 mm from the apex (P=0.044, 0.046, and <0.001; Fig. 2). Thus, pairwise comparisons of the groups were made at 0, 6, and 9 mm from the apex.
Fig. 2:
The error bar of mean and 95% confidence interval of mean of canal transportation before and after root canal treatment by different endodontic files.
The error bar of mean and 95% confidence interval of mean of canal transportation before and after root canal treatment by different endodontic files.At 0 and 6 mm from the apex, canal transportation by ETP was less than that by HCM (P=0.031 and 0.023). At 9 mm from the apex, canal transportations by HCM and ETP were not significantly different (P=0.838). At 9-mm level, canal transportation by the two rotary systems was significantly different from that by hand files (P<0.001). The comparison of canal transportation by HCM and hand files and by ETP and hand files at 0 and 6 mm from the apex revealed no significant difference (P=0.10, 0.56, 0.22, and 0.50; Table 1).
Table 1.
Mean and standard deviation (SD) of transportation (mm) of the mesiobuccal canal
Distance to apex (mm)
0
3
6
9
HCM
0.31±0.22
0.25±0.22
0.38±0.36
0.12±0.11
ETP
0.16±0.20
0.17±0.14
0.15±0.17
0.13±0.09
HKf
0.21±0.13
0.15±0.17
0.18±0.16
0.66±0.16
HCM: HyFlex CM, ETP: Edge Taper Platinum, HKf: Hand K-file
Mean and standard deviation (SD) of transportation (mm) of the mesiobuccal canalHCM: HyFlex CM, ETP: Edge Taper Platinum, HKf: Hand K-file
DISCUSSION
This study aimed to assess the efficacy of two newly introduced rotary file systems and traditional hand files by measuring the transportation of the maxillary mesiobuccal canal using CBCT.Several methods have been suggested for the assessment of the efficacy of endodontic files, root canal preparation techniques, and the quality of root canal preparation, allowing the comparison of the canal shape before and after root canal preparation. Conventional radiography and root sectioning are among these methods, which have some shortcomings. Conventional radiography provides a two-dimensional (2D) image of the samples and does not allow the assessment of root cross-sections [20-22]. Root sectioning used to be a common method; however, it damages the samples [23].The introduction of CBCT allowed for the assessment of the function of rotary files and the evaluation of root canal transportation. In this technique, CBCT scans are obtained before and after root canal preparation, measurements are made on the images, and the values are compared to detect any changes. This method is highly accurate and does not damage the samples. It also allows taking various images of the canal [16,24, 25]. In the current study, only the mesiobuccal canal of the maxillary first molars was used to minimize dispersion and range of variability among the samples. The mesiobuccal canal of first molars is among the most difficult canals for preparation since it is curved and often very narrow [26].Since the highest degree of curvature is often seen in the middle and apical thirds, these areas are more susceptible to procedural errors [27]. Therefore, in this study, sections were made at 0, 3, 6, and 9 mm from the apex to assess transportation [23,28]. Khademi et al [29] showed that for better penetration of irrigating solutions into the apical third of the root canal, this region must be prepared at least to size 30. Thus, in our study, the apical region was prepared to size 30 in all three groups.In the current study, canal transportation at 9 mm from the apex, which corresponds to the middle third of the root where the curvature starts, was less with the use of HCM and EPT rotary systems compared to hand files. This was in agreement with the results reported by Kumar et al [30], who compared HCM, Twisted File, and hand files. Also, our study showed no difference in canal transportation between HCM and ETP at 3 and 9 mm from the apex; however, both systems showed superior efficacy compared to hand files at the site of initiation of curvature. This finding was in accord with the results reported by Zhao et al [31], who stated acceptable results with minimal procedural errors using micro-CT.The search of the literature yielded no study on the efficacy of ETP. However, it should be noted that, in our study, ETP caused less canal transportation than HCM at 0 and 6 mm from the apex; therefore, it may be stated that it had a superior function compared to HCM.In our study, no significant difference was noted among the three groups in terms of canal transportation at 3 mm from the apex, which may be because the canal curvature at this level was mild, and all three methods had optimal efficacy.According to the manufacturer’s instructions, HCM must use the crown down technique in canal preparation while the single-length technique must be used with ETP. A previous study showed that Race file (the crown down technique) caused fewer irregularities in the canal compared to the Mtwo system (the single-length method) with superior canal centering ability [28]. However, in the current study, ETP showed superior results at 0 and 6 mm from the apex compared to HCM. The difference between our study and previous ones is in the type of teeth used, method of assessment of canal transportation, and type of files used. Less canal transportation with the ETP system compared to HCM may be attributed to the fewer number of files used in the apical region since six files in the ETP system is used for apical preparation versus seven files in the HCM system.
CONCLUSION
The ETP and HCM rotary systems showed less canal transportation at the curvature of the mesiobuccal canal of maxillary first molars compared to hand files. ETP showed superior efficacy in root canal preparation compared to HCM.