Increase in pulse transit time to the foot after epidural anaesthesia treatment.

A Babchenko1, E Davidson, D Adler, Y Ginosar, V Kurz, M Nitzan.   

Abstract

Epidurally induced anaesthetic treatment is a routine treatment for pain relief during surgical procedure, based on blocking the sensory and sympathetic fibres that mediate pain. The epidural sympathetic block results in relaxation of the muscle walls in the lower limbs, which can be assessed by the resultant haemodynamic changes. In the current study, the difference tt,f in the transit time of the blood pressure pulses between the toe and the finger is measured by photoplethysmography (PPG). Fifteen patients are administered 10 ml 0.25% of bupivacaine, ten patients are administered 10 ml 0.5%, and 17 patients are administered 40 ml 0.0625%. tt,f decreases as a function of the patient's age and blood pressure, both before and after the sympathetic block, owing to the decrease in arterial compliance with age and blood pressure. The time delay tt,f increases after the epidural treatment by 10.1+/-7.0 and by 16.8+/-10.8 ms for the 0.25% and the 0.5% concentrations, respectively. The time delay increase for the lowest concentration is not statistically significant. The toe-finger time delay change is found to reflect the haemodynamic changes induced by the sympathetic block with higher reliability than the routine methods of skin temperature or arterial blood pressure.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11217886     DOI: 10.1007/bf02344874

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  17 in total

1.  Very low frequency variability in arterial blood pressure and blood volume pulse.

Authors:  M Nitzan; A Babchenko; B Khanokh
Journal:  Med Biol Eng Comput       Date:  1999-01       Impact factor: 2.602

2.  Assessment of arterial distensibility by automatic pulse wave velocity measurement. Validation and clinical application studies.

Authors:  R Asmar; A Benetos; J Topouchian; P Laurent; B Pannier; A M Brisac; R Target; B I Levy
Journal:  Hypertension       Date:  1995-09       Impact factor: 10.190

3.  Estimation of arterial pulse wave velocities in the frequency domain: method and clinical considerations.

Authors:  M Okada; S Kimura; M Okada
Journal:  Med Biol Eng Comput       Date:  1986-05       Impact factor: 2.602

4.  Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography.

Authors:  J R Jago; A Murray
Journal:  Clin Phys Physiol Meas       Date:  1988-11

5.  Effects of aging on arterial distensibility in populations with high and low prevalence of hypertension: comparison between urban and rural communities in China.

Authors:  A P Avolio; F Q Deng; W Q Li; Y F Luo; Z D Huang; L F Xing; M F O'Rourke
Journal:  Circulation       Date:  1985-02       Impact factor: 29.690

6.  Arterial alterations with aging and high blood pressure. A noninvasive study of carotid and femoral arteries.

Authors:  A Benetos; S Laurent; A P Hoeks; P H Boutouyrie; M E Safar
Journal:  Arterioscler Thromb       Date:  1993-01

7.  The effect of long-acting glyceryl trinitrate on peripheral circulation.

Authors:  M Eliakim; D Sapoznikov; A Keynan; J Weinman
Journal:  Geriatrics       Date:  1972-06

Review 8.  Radial artery compliance and distensibility in hypertension and hypertension-related conditions.

Authors:  C Giannattasio
Journal:  Blood Press Suppl       Date:  1997

9.  Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis: aging and arterial compliance.

Authors:  G E McVeigh; C W Bratteli; D J Morgan; C M Alinder; S P Glasser; S M Finkelstein; J N Cohn
Journal:  Hypertension       Date:  1999-06       Impact factor: 10.190

10.  Forearm arterial distensibility in systolic hypertension.

Authors:  H Smulyan; S Vardan; A Griffiths; B Gribbin
Journal:  J Am Coll Cardiol       Date:  1984-02       Impact factor: 24.094

View more
  9 in total

1.  Pulse transit times to the capillary bed evaluated by laser Doppler flowmetry.

Authors:  Alan Bernjak; Aneta Stefanovska
Journal:  Physiol Meas       Date:  2009-02-06       Impact factor: 2.833

2.  Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera.

Authors:  In Cheol Jeong; Joseph Finkelstein
Journal:  J Med Syst       Date:  2016-01-20       Impact factor: 4.460

3.  The prolongation of pulse transit time after a stellate ganglion block: An objective indicator of successful block.

Authors:  Young Uk Kim; Yuseon Cheong; Yu Gyeong Kong; Jonghyuk Lee; Sehun Kim; Hong Gyu Choi; Jeong Hun Suh
Journal:  Pain Res Manag       Date:  2015-09-15       Impact factor: 3.037

4.  Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves.

Authors:  Marit H N van Velzen; Arjo J Loeve; Sjoerd P Niehof; Egbert G Mik
Journal:  Med Biol Eng Comput       Date:  2017-03-30       Impact factor: 2.602

5.  Change in pulse transit time in the lower extremity after lumbar sympathetic ganglion block: an early indicator of successful block.

Authors:  Eun-Young Joo; Yu Gyeong Kong; Jonghyuk Lee; Hyun-Seok Cho; Sung-Hoon Kim; Jeong Hun Suh
Journal:  J Int Med Res       Date:  2017-01-17       Impact factor: 1.671

6.  Unobtrusive Photoplethysmographic Monitoring Under the Foot Sole while in a Standing Posture.

Authors:  Seunghyeok Hong; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2018-09-26       Impact factor: 3.576

7.  Area Under the Curve of Finger Photoplethysmography as an Evaluation Measure for Sympathetic Activity During Lumbar Epidural Anaesthesia.

Authors:  Slobodan Mihaljevic; Milenko Bevanda; Kresimir Reiner; Krunoslav Sporcic; Ljiljana Mihaljevic; Marko Cacic
Journal:  Turk J Anaesthesiol Reanim       Date:  2018-03-01

8.  An assessment of pulse transit time for detecting heavy blood loss during surgical operation.

Authors:  Chien-Hao Wang; Cheng-Wei Lu; Tzu-Yu Lin; Maysam F Abbod; Jiann-Shing Shieh
Journal:  Open Biomed Eng J       Date:  2012-12-28

9.  Small intra-individual variability of the pre-ejection period justifies the use of pulse transit time as approximation of the vascular transit.

Authors:  Minke C Kortekaas; Marit H N van Velzen; Frank Grüne; Sjoerd P Niehof; Robert J Stolker; Frank J P M Huygen
Journal:  PLoS One       Date:  2018-10-10       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.