Literature DB >> 11597364

Performance of ultrasound echo decomposition using singular spectrum analysis.

W C de Albuquerque Pereira1, C D Maciel.   

Abstract

Diagnostic ultrasonography has its well-established role in medicine. Nevertheless, the quantitative characterisation of biological tissues by ultrasound (US) is still a main topic of research. Several parameters have been explored with this purpose, (e.g. attenuation, backscatter coefficient, US speed). More recently, mean scatterer space (MSS) has been proposed as a characterisation parameter. The objective of this work was to investigate the potential of the singular spectrum analysis (SSA) to estimate MSS. This method proposes the reconstruction of the periodic part of the original US signal from where the MSS of the medium can be estimated. SSA is applied to simulated and real backscattered echoes from a phantom and a bovine liver sample. Consistent results were obtained from both Monte-Carlo simulation and real data. They were compared with literature. Presently, precision, accuracy and sensibility of SSA are being investigated.

Entities:  

Mesh:

Year:  2001        PMID: 11597364     DOI: 10.1016/s0301-5629(01)00423-9

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  7 in total

1.  Experimental Validation of Perfusion Imaging With HOSVD Clutter Filters.

Authors:  Yang Zhu; MinWoo Kim; Cameron Hoerig; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-21       Impact factor: 2.725

2.  Singular spectrum analysis applied to ultrasonic detection and imaging of brachytherapy seeds.

Authors:  Jonathan Mamou; Ernest J Feleppa
Journal:  J Acoust Soc Am       Date:  2007-03       Impact factor: 1.840

3.  The singular value filter: a general filter design strategy for PCA-based signal separation in medical ultrasound imaging.

Authors:  F William Mauldin; Dan Lin; John A Hossack
Journal:  IEEE Trans Med Imaging       Date:  2011-06-20       Impact factor: 10.048

4.  Mean scatterer spacing estimation in normal and thermally coagulated ex vivo bovine liver.

Authors:  Nicholas Rubert; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2014-04       Impact factor: 1.578

5.  Scatterer number density considerations in reference phantom-based attenuation estimation.

Authors:  Nicholas Rubert; Tomy Varghese
Journal:  Ultrasound Med Biol       Date:  2014-04-13       Impact factor: 2.998

6.  Mean scatterer spacing estimation using multi-taper coherence.

Authors:  Nicholas Rubert; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-06       Impact factor: 2.725

7.  Analysis of Coherent and Diffuse Scattering Using a Reference Phantom.

Authors:  Ivan M Rosado-Mendez; Lindsey C Drehfal; James A Zagzebski; Timothy J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-03-25       Impact factor: 2.725

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.