Adaptive clutter filtering via blind source separation for two-dimensional ultrasonic blood velocity measurement.

Caterina M Gallippi1, Gregg E Trahey.   

Abstract

A method for adaptive clutter rejection via blind source separation (BSS) using principal and independent component analyses is presented in application to blood velocity measurement in the carotid artery. In particular, the filtering method's efficacy for eliminating clutter and preserving lateral blood flow signal components is presented. The performance of IIR filters is compromised by shorth data ensembles (10 to 20 temporal samples) as implemented for color-flow and high frame-rate imaging due to initialization requirements. Further, the ultrasonic imaging system's transfer function maps axial wall and lateral blood motion to overlapping spectra. As such, frequency domain-based approaches to wall filtering are ineffective for distinguishing wall from blood motion signals. Rather than operating in the frequency domain. BSS performs clutter rejection by decomposing the input data ensemble into N constitutive source signals in time, where N is the ensemble length. Source signal energy coupled with respective signal depth and time course profiles reveal which source signals correspond to blood, noise and clutter components. Clutter components may then be removed without disruption of lateral blood flow information needed for two-dimensional blood velocity measurement. A simplistic data simulation is employed to offer an intuitive understanding of BSS methods for signal separation. The adaptive BSS filter is further demonstrated using a Field II simulation of blood flow through the carotid artery including tissue motion. BSS clutter filter performance is compared to the performance of FIR, IIR and polynomial regression clutter filters. Finally, the filter is employed for clinical application using a Siemens Elegra scanner, carotid artery data with lateral blood flow collected from healthy volunteers, and Speckle Tracking; velocity magnitude and angle profiles are shown. Once again, the BSS clutter filter is contrasted to FIR, IIR and polynomial regression clutter filters using clinical examples. Velocities computed with Speckle Tracking after BSS wall filtering are highest in the center of the artery and diminish to low velocities near the vessel walls, with velocity magnitudes consistent with physiological expectations. These results demonstrate that the BSS adaptive filter sufficiently suppresses wall motion signal for clinical lateral blood velocity measurement using data ensembles suitable for color-flow and high frame-rate imaging.

Entities:  

Mesh:

Year:  2002        PMID: 12665237     DOI: 10.1177/016173460202400401

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  19 in total

1.  Experimental Validation of Perfusion Imaging With HOSVD Clutter Filters.

Authors:  Yang Zhu; MinWoo Kim; Cameron Hoerig; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-21       Impact factor: 2.725

2.  Robust principal component analysis and clustering methods for automated classification of tissue response to ARFI excitation.

Authors:  F William Mauldin; Hongtu T Zhu; Russell H Behler; Timothy C Nichols; Caterina M Gallippi
Journal:  Ultrasound Med Biol       Date:  2007-10-29       Impact factor: 2.998

3.  Complex principal components for robust motion estimation.

Authors:  F William Mauldin; Francesco Viola; William F Walker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-11       Impact factor: 2.725

4.  Improved Visualization in Difficult-to-Image Stress Echocardiography Patients Using Real-Time Harmonic Spatial Coherence Imaging.

Authors:  Dongwoon Hyun; Anna Lisa C Crowley; Melissa LeFevre; Jayne Cleve; Jarrett Rosenberg; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

5.  Visualization of Small-Diameter Vessels by Reduction of Incoherent Reverberation With Coherent Flow Power Doppler.

Authors:  You Leo Li; Dongwoon Hyun; Lotfi Abou-Elkacem; Juergen Karl Willmann; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11       Impact factor: 2.725

6.  Combining Slow Flow Techniques With Adaptive Demodulation for Improved Perfusion Ultrasound Imaging Without Contrast.

Authors:  Jaime Tierney; Kristy Walsh; Helen Griffith; Jennifer Baker; Daniel B Brown; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-02-07       Impact factor: 2.725

7.  Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging.

Authors:  Jaime Tierney; Crystal Coolbaugh; Theodore Towse; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2017-06-13       Impact factor: 10.048

8.  Effects of motion on correlations of pulse-echo ultrasound signals: Applications in delay estimation and aperture coherence.

Authors:  Dongwoon Hyun; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2020-03       Impact factor: 1.840

9.  Blind Source Separation - Based Motion Detector for Sub-Micrometer, Periodic Displacement in Ultrasonic Imaging.

Authors:  Md Murad Hossain; Diwash Thapa; Justin Sierchio; Amy Oldenburg; Caterina Gallippil
Journal:  IEEE Int Ultrason Symp       Date:  2016-11-03

10.  A motion-based approach to abdominal clutter reduction.

Authors:  Muyinatu A Lediju; Michael J Pihl; Stephen J Hsu; Jeremy J Dahl; Caterina M Gallippi; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-11       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.