| Literature DB >> 32320440 |
Antoine Girard1, Hervé Saint-Jalmes2, Nibras Chaboub2, Pierre-Jean Le Reste3, Alice Metais4, Anne Devillers1, Florence Le Jeune5, Xavier Palard-Novello2.
Abstract
INTRODUCTION: 3,4-dihydroxy-6-[18F]fluoro-L-phenylalanine (FDOPA) uptake quantification in glioma assessment can be distorted using a non-optimal time frame binning of time-activity curves (TAC). Under-sampling or over-sampling dynamic PET images induces significant variations on kinetic parameters quantification. We aimed to optimize temporal time frame binning for dynamic FDOPA PET imaging.Entities:
Mesh:
Substances:
Year: 2020 PMID: 32320440 PMCID: PMC7176128 DOI: 10.1371/journal.pone.0232141
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1List-mode PET data were recorded during 2400 seconds (A). The first seconds without any count were excluded and only 20 minutes from the FDOPA bolus arrival time were selected (B). Then, PET data were reconstructed into the 5 different time samplings (C).
Fig 2Axial FDOPA PET images show glioma uptake in a 50-year-old man (A) and the injected FDOPA bolus (176 MBq) on the right middle cerebral artery (B) with arterial and glioma time-activity curves (C).
Fig 3Box plots for TBRmax at 20 min p.i and 35 min p.i.
Comparison of the average K1 values from the 1024 simulations (Monte Carlo) using the 5 different time samplings.
| Time sampling | Average K1 value (mL/ccm/min-) +/- SD | 95% Confidence Interval (mL/ccm/min) | |
|---|---|---|---|
| Lower bound | Upper bound | ||
| 11x10sec-6x15sec-5x20sec-3x300sec | 0.1621 +/- 0.0146 | 0.1612 | 0.1630 |
| 6x20sec– 8x60sec– 2x300sec | 0.1634 +/- 0.0124 | 0.1627 | 0.1642 |
| 10x30sec– 3x300sec | 0.1690 +/- 0.0152 | 0.1689 | 0.17 |
| 4x45sec– 3x90sec– 5x150sec | 0.1745 +/- 0.0131 | 0.173 | 0.1753 |
Comparison of the K1 values extracted from the optimal time sampling (8x15sec– 2x30sec– 2x60sec– 3x300sec) and K1 values from the other time samplings for the 33 lesions.
| Time sampling | Average K1 value (mL/ccm/min) +/- SD | p value |
|---|---|---|
| 11x10sec-6x15sec-5x20sec-3x300sec | 0.214 +/- 0.2 | 0.178 |
| 6x20sec– 8x60sec– 2x300sec | 0.143 +/- 0.12 | 0.003 |
| 10x30sec– 3x300sec | 0.151 +/- 0.124 | 0.042 |
| 4x45sec– 3x90sec– 5x150sec | 0.146 +/- 0.130 | 0.002 |
*p values <0.05 = statistically significant
Spearman’s rank correlation matrix for the imaging parameters.
| 1 | 0.83 | 0.65 | 0.61 | 0.88 | 0.90 | 0.67 | |
| 1 | 0.21 | 0.48 | 0.60 | 0.68 | 0.29 | ||
| 1 | 0.55 | 0.78 | 0.73 | 0.87 | |||
| 1 | 0.60 | 0.63 | 0.31 | ||||
| 1 | 0.96 | 0.77 | |||||
| 1 | 0.69 | ||||||
| 1 |
*p values <0.05 = statistically significant