Literature DB >> 32197964

Patients Following Revision Total Hip Arthroplasty With Modular Dual Mobility Components and Cobalt-Chromium Inner Metal Head are at Risk of Increased Serum Metal Ion Levels.

Roberto Civinini1, Andrea Cozzi Lepri1, Christian Carulli1, Fabrizio Matassi1, Marco Villano1, Massimo Innocenti1.   

Abstract

BACKGROUND: Modular dual-mobility (MDM) total hip arthroplasty (THA) is designed with a cobalt-chromium liner inserted into a titanium acetabular component. The purpose of this study is to investigate the potential risks for fretting corrosion at this junction, by measuring serum metal ions, after MDM acetabular revision.
METHODS: Thirty-seven patients with well-functioning revision THAs participated in a cross-sectional study at mean 5.1 (2-10) years after surgery. All received a trabecular titanium MDM acetabular component. The serum levels of cobalt and chromium were measured using mass spectrometry.
RESULTS: The mean values of chromium and cobalt were 2.08 μg/L (95% confidence interval 0.9-3.2, range 0.02-11.8) and 1.99 μg/L (95% confidence interval 0.81-3.17, range 0.07-16.05), respectively. Eleven patients (29, 7%) had ion levels above the normal range, with 6 (16.2%) above 5 μg/L and 5 (13.5%) between 1 and 5 μg/L. A significant correlation was found between an elevated serum metal ion level and University of California Los Angeles score (P = .016).
CONCLUSION: We conclude that serum metal level elevation may occur secondary to metal debris resulting from corrosion of the index MDM THA. This potential risk should be included in the decision-making process when dealing with revision arthroplasty in young and active patients.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  chromium; cobalt; fretting corrosion; metal ions; modular dual mobility; revision total hip arthroplasty

Mesh:

Substances:

Year:  2020        PMID: 32197964     DOI: 10.1016/j.arth.2020.02.050

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  Trabecular titanium cups in acetabular revision arthroplasty: analysis of 10-year survivorship, restoration of center of rotation and osteointegration.

Authors:  Andrea Cozzi Lepri; Matteo Innocenti; Alberto Galeotti; Christian Carulli; Marco Villano; Roberto Civinini
Journal:  Arch Orthop Trauma Surg       Date:  2021-11-15       Impact factor: 2.928

2.  In Revision THA, Is the Re-revision Risk for Dislocation and Aseptic Causes Greater in Dual-mobility Constructs or Large Femoral Head Bearings? A Study from the Australian Orthopaedic Association National Joint Replacement Registry.

Authors:  Wayne Hoskins; Sophia Rainbird; Chelsea Dyer; Stephen E Graves; Roger Bingham
Journal:  Clin Orthop Relat Res       Date:  2022-01-03       Impact factor: 4.755

3.  Favourable clinical outcomes following cemented arthroplasty after metal-on-metal total hip replacement: a retrospective study with a mean follow-up of 10 years.

Authors:  Weiguang Yu; Meiji Chen; Xianshang Zeng; Mingdong Zhao; Xinchao Zhang; Junxing Ye; Jintao Zhuang; Guowei Han
Journal:  BMC Musculoskelet Disord       Date:  2020-11-21       Impact factor: 2.362

4.  Serum Metal Ions in Contemporary Monoblock and Modular Dual Mobility Articulations.

Authors:  Alexander Greenberg; Allina Nocon; Ivan De Martino; David J Mayman; Thomas P Sculco; Peter K Sculco
Journal:  Arthroplast Today       Date:  2021-10-29

5.  No Change in Serum Metal Ions Levels After Primary Total Hip Replacement With an Additively Manufactured Dual Mobility Acetabular Construct.

Authors:  Kyle Alpaugh; Mithun Mishu; Geoffrey Westrich
Journal:  Arthroplast Today       Date:  2022-08-30

Review 6.  Metal ion levels with use of modular dual mobility constructs: Can the evidence guide us on clinical use?

Authors:  Atul F Kamath; P Maxwell Courtney; Gwo-Chin Lee
Journal:  J Orthop       Date:  2021-02-20

Review 7.  Adverse reaction to metal debris due to fretting corrosion between the acetabular components of modular dual-mobility constructs in total hip replacement: a systematic review and meta-analysis.

Authors:  Jonathan M R French; Paul Bramley; Sean Scattergood; Nemandra A Sandiford
Journal:  EFORT Open Rev       Date:  2021-05-04

8.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

  8 in total