Literature DB >> 32185090

Considering inhomogeneities in Gamma Knife treatment planning: Factors affecting the loss of prescription dose coverage.

William N Duggar1, Rui He1, Rahul Bhandari1, Madhava Kanakamedala1, Bart Morris1, Roberto Rey-Dios2, Srinivasan Vijayakumar1, Claus Chunli Yang1.   

Abstract

OBJECT: To compare the consistency of the agreement between the Convolution and TMR10 algorithms using a homogeneous phantom and to identify target characteristics that lead to large changes in target isodose coverage when the Convolution algorithm is used in GammaPlan as opposed to the TMR10 algorithm.
METHODS: The IROC phantom end-to-end test was performed and RTDose for both the TMR10 and Convolution algorithm were submitted for comparison to the measurement. Treatment plans for 16 patients and 26 different targets were retrospectively re-calculated with the Convolution algorithm when originally planned with the TMR10 algorithm. Multivariate regression was used to find statistically significant predictors of loss in target prescription isodose coverage.
RESULTS: Both algorithms agreed well with the IROC TLD measurement (within 1 %) and slightly better agreement was seen in the film analysis for the Convolution algorithm. After multivariate regression, small target volumes, < 1cm from air cavity, and minimum dose to target were potential predictors of large percentage loss of prescription isodose coverage (p = 0.049, 0.026, and 0.002, respectively).
CONCLUSION: Convolution and TMR10 appear to be equivalent in homogeneous situations. Some target characteristics have been identified that might be indications for use of the Convolution algorithm in clinical practice.
© 2020 Old City Publishing, Inc.

Entities:  

Keywords:  Gamma Knife Dose Calculation Convolution TMR10

Year:  2020        PMID: 32185090      PMCID: PMC7065893     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  13 in total

1.  Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm.

Authors:  M Fippel
Journal:  Med Phys       Date:  1999-08       Impact factor: 4.071

2.  Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels.

Authors:  Weiguo Lu; Gustavo H Olivera; Ming-Li Chen; Paul J Reckwerdt; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2005-02-21       Impact factor: 3.609

3.  The implementation of an advanced treatment planning algorithm in the treatment of lung cancer with conventional radiotherapy.

Authors:  M Pearson; P Atherton; R McMenemin; F McDonald; G Mazdai; P Mulvenna; G Lambert
Journal:  Clin Oncol (R Coll Radiol)       Date:  2009-01-22       Impact factor: 4.126

4.  Verification of dose profiles generated by the convolution algorithm of the gamma knife® radiosurgery planning system.

Authors:  Hyun-Tai Chung; Jeong-Hoon Park; Kook Jin Chun
Journal:  Med Phys       Date:  2017-07-28       Impact factor: 4.071

5.  Credentialing results from IMRT irradiations of an anthropomorphic head and neck phantom.

Authors:  Andrea Molineu; Nadia Hernandez; Trang Nguyen; Geoffrey Ibbott; David Followill
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

6.  A comparison of the convolution and TMR10 treatment planning algorithms for Gamma Knife® radiosurgery.

Authors:  Peter Fallows; Gavin Wright; Natalie Harrold; Peter Bownes
Journal:  J Radiosurg SBRT       Date:  2018

7.  Gamma Knife radiosurgery with CT image-based dose calculation.

Authors:  Andy Yuanguang Xu; Jagdish Bhatnagar; Greg Bednarz; Ajay Niranjan; Douglas Kondziolka; John Flickinger; L Dade Lunsford; M Saiful Huq
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

8.  Investigation of dosimetric differences between the TMR 10 and convolution algorithm for Gamma Knife stereotactic radiosurgery.

Authors:  Alvaro Rojas-Villabona; Neil Kitchen; Ian Paddick
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

9.  Comparison of the Convolution algorithm with TMR10 for Leksell Gamma knife and dosimetric verification with radiochromic gel dosimeter.

Authors:  Petra Osmancikova; Josef Novotny; Jaroslav Solc; Jan Pipek
Journal:  J Appl Clin Med Phys       Date:  2017-12-10       Impact factor: 2.102

10.  Dose differences between the three dose calculation algorithms in Leksell GammaPlan.

Authors:  Andy Yuanguang Xu; Jagdish Bhatnagar; Greg Bednarz; Ajay Niranjan; John Flickinger; L Dade Lunsford; M Saiful Huq
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.