Literature DB >> 32168241

Efficacy of Swept-source Optical Coherence Tomography in Axial Length Measurement for Advanced Cataract Patients.

Chareenun Chirapapaisan, Sabong Srivannaboon1, Pratuangsri Chonpimai1.   

Abstract

SIGNIFICANCE: A major limitation of standard time-domain optical coherence tomography-based biometers (TD-OCT) is an inability to measure the axial length (AL) in advanced cataract. A new device that uses swept-source optical coherence tomography (SS-OCT) allows better light penetration. Hence, a considerable number of cataract patients who failed AL measurement by TD-OCT can be recovered by SS-OCT.
PURPOSE: The purposes of this study were to evaluate the efficacy of an SS-OCT for AL measurement in advanced cataract patients and to identify characteristics of lens opacity that impede the AL measurement.
METHODS: Advanced cataract patients who were unable to obtain AL measurement using a standard TD-OCT-based optical biometer (IOLMaster500; Carl Zeiss Meditec, Jena, Germany) were recruited in this study. The AL was remeasured using SS-OCT (IOLMaster700), followed by measurement with immersion ultrasonography (IU). The percentage of patients who achieved AL measurement by SS-OCT was recorded. The AL obtained from SS-OCT was then verified by comparing with the AL derived from IU. The cataract type of each patient was classified according to standard Lens Opacity Classification III score. The association between characteristics of cataract and successful AL measurement by SS-OCT was analyzed.
RESULTS: Sixty-four eyes that failed AL measurement from TD-OCT were included. Fifty-six eyes (87.5%) were able to be measured by SS-OCT (95% confidence interval, 77.23 to 93.53%). The AL obtained by SS-OCT showed very high agreement with those derived from IU (intraclass correlation coefficient, 0.99). There was no statistically significant correlation between characteristics of lens opacity and the capability of SS-OCT for AL measurement (P > .05). However, there was a trend toward an inability to measure the AL in cataracts with a high grade of lens opacity.
CONCLUSIONS: The efficacy of SS-OCT-based optical biometer was excellent. Of the patients with advanced cataract who failed the AL measurement by TD-OCT, 87.5% could be recovered by SS-OCT. However, there was no specific type of lens opacity associated with a failure of AL measurement using SS-OCT.

Entities:  

Year:  2020        PMID: 32168241     DOI: 10.1097/OPX.0000000000001491

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  2 in total

1.  Commentary: Efficacy of swept-source optical coherence tomography in dense cataract.

Authors:  Robin Malik; Atul Kumar Singh
Journal:  Indian J Ophthalmol       Date:  2022-01       Impact factor: 1.848

2.  Comparison of ocular biometry and refractive outcome between ANTERION and IOL Master 700.

Authors:  Amita Panda; Ashok Nanda; Kalyani Sahoo
Journal:  Indian J Ophthalmol       Date:  2022-05       Impact factor: 2.969

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.