Literature DB >> 32120280

PICC-PORT: Valid indication to placement in patient with results of extensive skin burns of the neck and chest in oncology. The first case in the scientific literature.

D Merlicco1, M Lombardi2, M C Fino3.   

Abstract

INTRODUCTION: The management of patients with advanced gastric cancer requires a stable venous access required at different stages of disease (treatment phase, palliative phase). Totally implantable central venous access in the arm, named PICC-PORT, is used in a patient with results of extensive skin burns of the neck, chest and right arm and surgical outcomes of multiple skin grafts of chest. The described clinical case is the first event in the scientific literature. PRESENTATION OF CASE: We report a case of a patient with results of extensive skin burns of the neck, chest and right arm and surgical outcomes of multiple skin grafts of chest that must perform chemotherapy with a port. In this patient, due to the difficulty of implanting a door in the cervico-thoracic district, we opt for the totally subcutaneous implantation of the vascular device (PICC-PORT 5 Fr) in the left arm. DISCUSSION: In this patient for the difficulty of implanting a port in the cervico-thoracic district, we opt for the totally subcutaneous implantation of the vascular device (PICC-PORT) in the arm. The PICC-PORT is positioned with the same technique as the PICC (ultrasound-guided vein puncture, with modified Seldinger technique and tip location with ECG technique); presents all the functional and aesthetic advantages of a totally subcutaneous device.The case described is the first case in the scientific literature.
CONCLUSION: In Europe in recent years for the availability of the vascular device of small dimensions and materials increasingly compatible, the "PICC-PORT" is positioned in the veins of the arm with ultrasound-guidance without complications such as pneumothorax, arterial puncture, hematoma of the neck, Pinch-off syndrome, such as the clinical case presented with extensive scars on the chest and neck. Thoracic devices (chest port, tunnel venous catheter) are not indicated in thickened and inelastic skins, due to the high risk of dehiscence of the surgical wound.
Copyright © 2020 The Authors. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Brachial port; Chemotherapy; PICC-PORT; Totally implantable central venous access

Year:  2020        PMID: 32120280      PMCID: PMC7052438          DOI: 10.1016/j.ijscr.2020.02.028

Source DB:  PubMed          Journal:  Int J Surg Case Rep        ISSN: 2210-2612


Introduction

The management of patients with advanced gastric cancer requires a stable venous access required at different stages of disease (diagnostic phase, treatment phase, palliative phase) [1]. Totally implantable central venous access (Port) is often used for ensure safe infusions of chemotherapy or pain management and supportive care in cancer patients. Local and systemic complications may occur both during and after placement of port despite the well-established techniques for its placement and care. Incidence and nature of complications of central venous catheter have been well established for long-term chemotherapy. However, very sparse data exists on the incidence of complications of molecularly targeted therapies administered through a totally implantable central venous access [2]. Retrospectively analyzing patients undergoing conventional chemotherapy, we report a case of a patient with results of extensive skin burns of the neck, chest and right arm and surgical outcomes of multiple skin grafts of chest to which a “PICC-PORT” was implanted in the left brachial vein [[3], [4], [5], [6]]. In this patient for the difficulty of implanting a port in the cervical-thoracic district, we recommend the totally subcutaneous implantation of the vascular device with peripheral access to the left arm, the PICC-PORT; other indications in our experience are head and neck cancer, patients with Radiodermatitis by radiation therapy for head and neck cancer, patients with ostomies (tracheobronchial/esophagus-ostomy), patients in molecular targeted therapy (EGFR-i), patients with severe kyphosis, patients with breast implants bilaterally, is added to the patient with extensive burns to the neck and chest or further skin grafts. In Europe in recent years, for the availability of the vascular device of small dimensions and materials increasingly compatible, are implanting "PICC-PORT"; they are placed in the veins of the arm with ultrasound-guidance and the system appears to be free of early complications such as pneumothorax, arterial puncture, hematoma of the neck, pinch off syndrome [7]. This work has been reported in line with the SCARE criteria [8].

Presentation of case

The patient is a 45-year-old man, in the November 2015 found during clinical-instrumental tests an advanced gastric cancer and subjected to Gastrectomy Subtotal with Billroth II reconstruction; in December 2015 comes to our observation in the DH of Oncology to undergo adjuvant chemotherapy. The oncologist, in anticipation of a combination chemotherapy with ECF (Epirubicin + Cisplatin + 5-FU), requires a stable central venous access for advanced disease. Comes to our Vascular Access Ambulatory, the patient's medical examination showed the scars from a previous large burn of the neck, chest and right arm and surgical outcomes of multiple skin grafts chest (Image 1).
Image 1

Results of extensive skin burns of the neck, chest and right arm and surgical outcomes of multiple skin grafts of chest.

Results of extensive skin burns of the neck, chest and right arm and surgical outcomes of multiple skin grafts of chest. The difficulty of implanting a port in the cervical-thoracic district, we opt for the totally subcutaneous implantation of the vascular device in the left arm. We performed an US of the left arm to assess the diameters of the brachial veins and basilica; it detects an internal brachial vein of good caliber 6,9 mm and you decide to implant a “PICC-PORT” (Images 2 and 3).
Image 2

Ultrasound of arm veins; diameter of the brachial vein of the left arm.

Image 3

Type of port: Conventional Port and Picc-Port.

Ultrasound of arm veins; diameter of the brachial vein of the left arm. Type of port: Conventional Port and Picc-Port. The device used for the plant was a Brachial Micro-Port 5 Fr, PUR, non-valved catheter, with hybrid reservoir (Titanium e Polyoxymethylene), in internal brachial vein left with ultrasound/ECG guidance (Image 4).
Image 4

Device 5 Fr used for placement of Picc-Port.

Device 5 Fr used for placement of Picc-Port.

Discussion

The implantation of PICC-PORT was performed in patient with results of extensive skin burns of the chest; the catheter was placed in arm without skin burns; the vein of choice for US-guided puncture was the internal brachial. There were no early postoperative complications (hematoma, bleeding, displacements, rotations, detachment of the CVC from the reservoir) (Image 5).
Image 5

Post-procedural chest radiography.

Post-procedural chest radiography. The outcomes at 395 days (corresponds to the patient's death) after implantation is optimal, it was not complicated by thrombotic or infectious phenomena and the patient is satisfied in terms of aesthetic and social reintegration (Image 6).
Image 6

Picc-Port to the left arm, 365 days after implant.

Picc-Port to the left arm, 365 days after implant.

Conclusion

The PICC-PORT is a Vascular Device, used in recent years, for the administration of Poly-Chemotherapies or Parenteral Nutrition (NP) or Chronic Pain Therapies; it is a device made up of a totally implantable brachial chamber and a central venous catheter in PUR (polyurethane) or SIL (silicone). The PICC-PORT is positioned with the same technique as the PICC (ultrasound-guided vein puncture, with modified Seldinger technique and tip location with ECG technique); presents all the functional and aesthetic advantages of a totally subcutaneous device. In the illustrated clinical case, the patient has extensive scars on the chest and neck, therefore the thoracic devices (chest Port, Tunneled venous catheter) cannot be implanted for thickened, inelastic skin, with a high risk of dehiscence of the surgical wound. The case described is the first case in the scientific literature. Implantation of the PICC-PORT is indicated in patient with head and neck cancer, patients with Radiodermatitis by radiation therapy for head and neck cancer, patients with ostomies (tracheobronchial/esophagus-ostomy), patients in molecular targeted therapy (EGFR-i), patients with severe kyphosis, patients with breast implants bilaterally, but with this case-report we can say even in patient with extensive burns to the neck, chest or further skin grafts. The PICC-PORT is positioned in the veins of the arm with ultrasound-guidance and the system appears to be free of early complications such as pneumothorax, arterial puncture, hematoma of the neck, Pinch-off syndrome.

Sources of funding

None.

Ethical approval

The ethical approval has been exempted by my institution.

Consent

Written informed consent was obtained from the patient for publication of this case report and accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal on request.

Author contributions

Dr. Domenico Merlicco, Chief of the Vascular Access Center - Division of Surgery, University Polyclinic Foggia - Lucera (Fg), Italy: 50% contributed to the manuscript. Dr. Massimo Lombardi, Oncology Operative Unit, San Severo Hospital (Fg), Italy: 25% contributed to the manuscript. Dr. Maria Carmela Fino, Clinical Oncology Nurse, University Polyclinic Foggia - Lucera (Fg), Italy: 25% contributed to the manuscript.

Registration of research studies

All the authors have made substantial contributions to all the following aspects: (1) study design and planning, data acquisition, data analysis and interpretation, (2) article writing or critical review of important intellectual contents (3) approval final version to be presented. All authors have read and approved the manuscript for publication.

Guarantor

Domenico Merlicco MD, Chief of the Vascular Access Center, University Polyclinic Foggia - Lucera (Fg), Italy.

Provenance and peer review

Not commissioned, externally peer-reviewed.

Declaration of Competing Interest

Dr. Domenico Merlicco reported no biomedical financial interests or potential conflicts of interest. Dr. Massimo Lombardi reported no biomedical financial interests or potential conflicts of interest. Dr. Maria Carmela Fino reported no biomedical financial interests or potential conflicts of interest.
  8 in total

1.  Peripherally inserted central catheter ports: A vascular access specialist's systematic approach.

Authors:  Theodoros Katsoulas; Maria Kapritsou; Evan Alexandrou; Maria Bastaki; Margarita Giannakopoulou; Panagiotis Kiekkas; Emmanouil Stafylarakis; Evangelos A Konstantinou
Journal:  J Vasc Nurs       Date:  2019-04-23

2.  The SCARE 2018 statement: Updating consensus Surgical CAse REport (SCARE) guidelines.

Authors:  Riaz A Agha; Mimi R Borrelli; Reem Farwana; Kiron Koshy; Alexander J Fowler; Dennis P Orgill
Journal:  Int J Surg       Date:  2018-10-18       Impact factor: 6.071

3.  Percutaneous image-guided implantation of totally implantable venous access ports in the forearm or the chest? A patients' point of view.

Authors:  Jan Peter Goltz; Bernhard Petritsch; Johannes Kirchner; Dietbert Hahn; Ralph Kickuth
Journal:  Support Care Cancer       Date:  2012-07-25       Impact factor: 3.603

Review 4.  Totally implantable vascular access devices 30 years after the first procedure. What has changed and what is still unsolved?

Authors:  Roberto Biffi; Adriana Toro; Simonetta Pozzi; Isidoro Di Carlo
Journal:  Support Care Cancer       Date:  2014-06       Impact factor: 3.603

Review 5.  Central venous access: techniques and indications in oncology.

Authors:  Pierre-Yves Marcy
Journal:  Eur Radiol       Date:  2008-05-06       Impact factor: 5.315

6.  Long-term outcomes of peripheral arm ports implanted in patients with colorectal cancer.

Authors:  Junichiro Kawamura; Satoshi Nagayama; Akinari Nomura; Atsushi Itami; Hiroshi Okabe; Seiji Sato; Go Watanabe; Yoshiharu Sakai
Journal:  Int J Clin Oncol       Date:  2008-08-15       Impact factor: 3.402

7.  Is radiologic placement of an arm port mandatory in oncology patients?: analysis of a large bi-institutional experience.

Authors:  Pierre-Yves Marcy; Nicolas Magné; Pierre Castadot; Antoine Italiano; Nicolas Amoretti; Cédric Bailet; Franck Bentolila; Jean-Claude Gallard
Journal:  Cancer       Date:  2007-11-15       Impact factor: 6.860

8.  Upper arm central venous port implantation: a 6-year single institutional retrospective analysis and pictorial essay of procedures for insertion.

Authors:  Masatoshi Shiono; Shin Takahashi; Yuichi Kakudo; Masanobu Takahashi; Hideki Shimodaira; Shunsuke Kato; Chikashi Ishioka
Journal:  PLoS One       Date:  2014-03-10       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.