A depth dependence determination of the wedge transmission factor for 4-10 MV photon beams.

E C McCullough1, J Gortney, C R Blackwell.   

Abstract

The depth dependence (up to 25 cm) of the in-phantom wedge transmission factor (WTF) has been determined for three medical linear accelerator x-ray beams with energies of 4, 6, and 10 MV containing 15 degrees-60 degrees (nominal) brass wedges. All measurements were made with a cylindrical ionization chamber in water, for a field size of 10 X 10 cm2 with a source-skin distance of 80 or 100 cm. We conclude that, for the accelerators studied, the WTF factor at depth is less than 2% different from that determined at dmax (for the nominal wedge angles and photon energies studied) unless the depth of interest is greater than 10 cm. Up to the maximum depth studied (25 cm) the relative wedge factor--that is, wedge factor at depth compared to that determined at dmax--was about equal to or less than 1.02 for the 15 degrees and 30 degrees wedges and any of the photon beam energies studied. For the seldom utilized combination of a nominal wedge angle in excess of 45 degrees with a depth greater than 10 cm, the WTF at depth can differ from the WTF determined at dmax, by up to 5%. Since the wedge transmission factor is reflective of relative percent dose data, our results also indicate that it is in error to use open field percent depth doses for certain combinations of wedge angle, photon energy, and depth.

Entities:  

Mesh:

Year:  1988        PMID: 3211057     DOI: 10.1118/1.596216

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

2.  Studying wedge factors and beam profiles for physical and enhanced dynamic wedges.

Authors:  Misbah Ahmad; Amjad Hussain; Wazir Muhammad; Syed Qaisar Abbas Rizvi
Journal:  J Med Phys       Date:  2010-01

3.  Design and clinical implementation of a TG-106 compliant linear accelerator data management system and MU calculator.

Authors:  Nabil Adnani
Journal:  J Appl Clin Med Phys       Date:  2010-04-30       Impact factor: 2.102

4.  Determination of field size-dependent wedge factors from a few selected measurements.

Authors:  Richard A Popple; Ivan A Brezovich; Jun Duan; Sui Shen; Prem N Pareek; Sung-Joon Ye
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

5.  Enhanced dynamic wedge output factors for Varian 2300CD and the case for a reference database.

Authors:  Christopher F Njeh
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.