Literature DB >> 32103867

The Molybdenum K-shell X-ray Emission Spectrum.

Marcus H Mendenhall1, Lawrence T Hudson1, Csilla I Szabo2,1, Albert Henins1, James P Cline1.   

Abstract

We present newly measured spectra of the X-ray emission of a molybdenum metal anode subject to electron bombardment, using a very high dispersion silicon double-crystal spectrometer. The measurement includes the dipole-allowed KL, KM, and KN emission lines, based on an energy scale traceable to the Système International (SI) definition of the meter with a systematic uncertainty below ΔE/E = 10-6. The data are presented as parametrized multi-Lorentzian fits to the results, and as supplementary data with the complete spectrum of each line group, corrected for instrumental effects. The MoKL 3 (Kα 1) line energy was in complete statistical agreement with published measurements, and it showed no asymmetry. Other lines showed varying discrepancies with the literature which lie outside the bounds of probable experimental errors.

Entities:  

Year:  2019        PMID: 32103867      PMCID: PMC7043325          DOI: 10.1088/1361-6455/ab45d6

Source DB:  PubMed          Journal:  J Phys B At Mol Opt Phys        ISSN: 0953-4075            Impact factor:   1.917


  3 in total

1.  A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science.

Authors:  W B Doriese; P Abbamonte; B K Alpert; D A Bennett; E V Denison; Y Fang; D A Fischer; C P Fitzgerald; J W Fowler; J D Gard; J P Hays-Wehle; G C Hilton; C Jaye; J L McChesney; L Miaja-Avila; K M Morgan; Y I Joe; G C O'Neil; C D Reintsema; F Rodolakis; D R Schmidt; H Tatsuno; J Uhlig; L R Vale; J N Ullom; D S Swetz
Journal:  Rev Sci Instrum       Date:  2017-05       Impact factor: 1.523

2.  High-precision measurement of the X-ray Cu Kα spectrum.

Authors:  Marcus H Mendenhall; Albert Henins; Lawrence T Hudson; Csilla I Szabo; Donald Windover; James P Cline
Journal:  J Phys B At Mol Opt Phys       Date:  2017-05-12       Impact factor: 1.917

3.  Characterization of a self-calibrating, high-precision, stacked-stage, vertical dual-axis goniometer.

Authors:  Marcus H Mendenhall; Albert Henins; Donald Windover; James P Cline
Journal:  Metrologia       Date:  2016-04-11       Impact factor: 3.157

  3 in total
  1 in total

1.  A multipurpose laboratory diffractometer for operando powder X-ray diffraction investigations of energy materials.

Authors:  Holger Geßwein; Pirmin Stüble; Daniel Weber; Joachim R Binder; Reiner Mönig
Journal:  J Appl Crystallogr       Date:  2022-05-16       Impact factor: 4.868

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.