Literature DB >> 27330224

Characterization of a self-calibrating, high-precision, stacked-stage, vertical dual-axis goniometer.

Marcus H Mendenhall1, Albert Henins1, Donald Windover1, James P Cline1.   

Abstract

We present details on the alignment and calibration of a goniometer assembly consisting two stacked, optically encoded, vertical axis rotation stages. A technique for its calibration is presented that utilizes a stable, uncalibrated, third stage to position a mirror in conjunction with a nulling autocollimator. Such a system provides a self-calibrating set of angular stages with absolute accuracy of ±0.1 second of plane angle (k=2 expanded uncertainty) around the full circle, suitable for laboratory application. This calibration technique permits in situ, absolute angular calibration of an operational goniometer assembly that is requisite for fully traceable angle measurement, as the installation of the encoder is known to change its performance from the angular calibration data provided by the manufacturer.

Entities:  

Year:  2016        PMID: 27330224      PMCID: PMC4911639          DOI: 10.1088/0026-1394/53/3/933

Source DB:  PubMed          Journal:  Metrologia        ISSN: 0026-1394            Impact factor:   3.157


  5 in total

1.  High-precision measurement of the X-ray Cu Kα spectrum.

Authors:  Marcus H Mendenhall; Albert Henins; Lawrence T Hudson; Csilla I Szabo; Donald Windover; James P Cline
Journal:  J Phys B At Mol Opt Phys       Date:  2017-05-12       Impact factor: 1.917

2.  The Molybdenum K-shell X-ray Emission Spectrum.

Authors:  Marcus H Mendenhall; Lawrence T Hudson; Csilla I Szabo; Albert Henins; James P Cline
Journal:  J Phys B At Mol Opt Phys       Date:  2019       Impact factor: 1.917

3.  Contemporary x-ray wavelength metrology and traceability.

Authors:  L T Hudson; J P Cline; A Henins; M H Mendenhall; C I Szabo
Journal:  Radiat Phys Chem Oxf Engl 1993       Date:  2019-07-03       Impact factor: 2.858

4.  Reconstruction of the Image Metric of Periodic Structures in an Opto-Digital Angle Measurement System.

Authors:  Alexander N Korolev; Alexander Ya Lukin; Yurii V Filatov; Vladimir Yu Venediktov
Journal:  Sensors (Basel)       Date:  2021-06-27       Impact factor: 3.576

5.  H2O2 rejuvenation-mediated synthesis of stable mixed-morphology Ag3PO4 photocatalysts.

Authors:  Henry Agbe; Nadeem Raza; David Dodoo-Arhin; Aditya Chauhan; Ramachandran Vasant Kumar
Journal:  Heliyon       Date:  2018-04-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.