Literature DB >> 25047798

Inappropriate use of the quasi-reversible electrode kinetic model in simulation-experiment comparisons of voltammetric processes that approach the reversible limit.

Alexandr N Simonov1, Graham P Morris, Elena A Mashkina, Blair Bethwaite, Kathryn Gillow, Ruth E Baker, David J Gavaghan, Alan M Bond.   

Abstract

Many electrode processes that approach the "reversible" (infinitely fast) limit under voltammetric conditions have been inappropriately analyzed by comparison of experimental data and theory derived from the "quasi-reversible" model. Simulations based on "reversible" and "quasi-reversible" models have been fitted to an extensive series of a.c. voltammetric experiments undertaken at macrodisk glassy carbon (GC) electrodes for oxidation of ferrocene (Fc(0/+)) in CH3CN (0.10 M (n-Bu)4NPF6) and reduction of [Ru(NH3)6](3+) and [Fe(CN)6](3-) in 1 M KCl aqueous electrolyte. The confidence with which parameters such as standard formal potential (E(0)), heterogeneous electron transfer rate constant at E(0) (k(0)), charge transfer coefficient (α), uncompensated resistance (Ru), and double layer capacitance (CDL) can be reported using the "quasi-reversible" model has been assessed using bootstrapping and parameter sweep (contour plot) techniques. Underparameterization, such as that which occurs when modeling CDL with a potential independent value, results in a less than optimal level of experiment-theory agreement. Overparameterization may improve the agreement but easily results in generation of physically meaningful but incorrect values of the recovered parameters, as is the case with the very fast Fc(0/+) and [Ru(NH3)6](3+/2+) processes. In summary, for fast electrode kinetics approaching the "reversible" limit, it is recommended that the "reversible" model be used for theory-experiment comparisons with only E(0), Ru, and CDL being quantified and a lower limit of k(0) being reported; e.g., k(0) ≥ 9 cm s(-1) for the Fc(0/+) process.

Entities:  

Year:  2014        PMID: 25047798     DOI: 10.1021/ac5019952

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Assessment of Boron Doped Diamond Electrode Quality and Application to In Situ Modification of Local pH by Water Electrolysis.

Authors:  Tania L Read; Julie V Macpherson
Journal:  J Vis Exp       Date:  2016-01-06       Impact factor: 1.355

2.  Disposable glassy carbon stencil printed electrodes for trace detection of cadmium and lead.

Authors:  Alyssa A Kava; Chloe Beardsley; Josephine Hofstetter; Charles S Henry
Journal:  Anal Chim Acta       Date:  2019-12-31       Impact factor: 6.558

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.