| Literature DB >> 32063505 |
Kishor Sapkota1, Sandra Franco2, Madalena Lira2.
Abstract
PURPOSES: To compare contrast sensitivity function (CSF) with soft contact lens (SCL) and spectacles wear. To investigate the effect of a three-month period of SCL wear on CSF.Entities:
Keywords: Contrast sensitivity function; Frecuencia espacial; Función de sensibilidad al contraste; Lentillas blandas; Soft contact lens; Spatial frequency; Spectacles wear; Uso de gafas
Mesh:
Year: 2020 PMID: 32063505 PMCID: PMC7182777 DOI: 10.1016/j.optom.2020.01.002
Source DB: PubMed Journal: J Optom ISSN: 1989-1342
Characteristics of the lenses used in the study. Nelfilcon A and nesofilcon A are hydrogel lenses while others are silicone hydrogel lenses.
| Lotrafilcon B | Comfilcon A | Balafilcon A | Stenofilcon A | Nelfilcon A | Nesofilcon A | |
|---|---|---|---|---|---|---|
| Company | Alcon | Cooper Vision | Bausch & Lomb | Cooper Vision | Alcon | Bausch & Lomb |
| Brand name | AirOptix® AquaTM | BiofinityTM | Purevision2TM | MyDayTM | Dailies® AquaComfort Plus® | BiotrueTM ONEday |
| Water content (%) | 34 | 48 | 36 | 54 | 69 | 78 |
| Thickness (mm) | 0.08 | 0.08 | 0.07 | 0.08 | 0.10 | 0.1 |
| Base curve/ diameter (mm) | 8.6/14.2 | 8.7/14.5 | 8.6/14 | 8.4/14.2 | 8.7/14 | 8.6/14.2 |
| Oxygen Permeability (barrer)m | 110 | 128 | 91 | 80 | 26 | 42 |
| Modulus (MPa) | 1.2 | 0.75 | 1.1-1.25 | 0.4 | 0.89 | 0.49 |
| Transmissibility (barrer/cm) | 137.5 | 160 | 130 | 100 | 26 | 42 |
Contrast sensitivity function (in Log Units) with spectacles and with contact lenses on the first day and with contact lenses on the final day.
| Spatial frequency (cpd) | Baseline with spectacles | Baseline with CL | p | Final with CL | p |
|---|---|---|---|---|---|
| 3 | 1.58 ± 0.20 | 1.66 ± 0.16 | 0.001 | 1.67 ± 0.14 | 0.502 |
| 6 | 1.76 ± 0.23 | 1.86 ± 0.20 | 0.000 | 1.88 ± 0.19 | 0.316 |
| 12 | 1.44 ± 0.26 | 1.53 ± 0.24 | 0.004 | 1.52 ± 0.25 | 0.875 |
| 18 | 1.03 ± 0.28 | 1.08 ± 0.23 | 0.114 | 1.09 ± 0.26 | 0.687 |
Comparison between CL and spectacles on baseline visit (day 1).
Comparison between baseline with CL and with CL after three months [CL: contact lenses].
Figure 1Graph showing contrast sensitivity function with different spatial frequencies.
Changes in contrast sensitivity function (in Log Units) by three months of soft contact lens wear with different lens materials.
| 3 cpd | 6 cpd | 12 cpd | 18 cpd | |
|---|---|---|---|---|
| Lotrafilcon B | 0.04 ± 0.17 [0.464] | 0.08 ± 0.22 [0.217] | 0.07 ± 0.40 [0.608] | −0.02 ± 0.31 [0.805] |
| Comfilcon A | 0.04 ± 0.09 [0.052] | −0.01 ± 0.18 [0.320] | 0.05 ± 0.26 [0.506] | 0.003 ± 0.24 [0.758] |
| Balafilcon A | −0.01 ± 0.15 [0.464] | 0.001 ± 0.17 [0.916] | −0.13 ± 0.27 [0.053] | 0.02 ± 0.27 [0.959] |
| Nelfilcon A | −0.02 ± 0.19 [0.465] | 0.05 ± 0.22 [0.422] | 0.03 ± 0.33 [0.527] | 0.07 ± 0.29 [0.318] |
| Stenofilcon A | 0.02 ± 0.10 [0.330] | 0.03 ± 0.17 [0.354] | 0.01 ± 0.13 [0.892] | −0.04 ± 0.18 [0.473] |
| Nesofilcon A | 0.03 ± 0.18 [0.549] | −0.01 ± 0.12 [0.863] | −0.07 ± 0.33 [0.717] | 0.04 ± 0.28 [0.474] |
Mean values ± standard deviations are followed by p values in bracket.
Figure 2Graph showing baseline and final contrast sensitivity function with different spatial frequencies with contact lenses of different materials.