Large Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter.

T Su1, P Reymond2, O Brina2, P Bouillot3, P Machi2, B M A Delattre4, L Jin1, K O Lövblad2, M I Vargas5.   

Abstract

BACKGROUND AND
PURPOSE: Flow diverter-induced hemodynamic change plays an important role in the mechanism of intracranial aneurysm occlusion. Our aim was to explore the relationship between aneurysm features and flow-diverter treatment of unruptured sidewall intracranial aneurysms.
MATERIALS AND METHODS: MR imaging, 4D phase-contrast, was prospectively performed before flow diverter implantation in each patient with unruptured intracranial aneurysm. Two postprocedure follow-ups were scheduled at 6 and 12 months. Responses were grouped according to whether the aneurysms were occluded or remnant. Preprocedural aneurysm geometries and ostium hemodynamics in 38 patients were compared between the 2 groups at 6 and 12 months. Receiver operating characteristic curve analyses were performed for significant geometric and hemodynamic continuous parameters.
RESULTS: After the 6-month assessment, 21 of 41 intracranial aneurysms were occluded, and 9 additional aneurysms were occluded at 12 months. Geometrically, the ostium maximum diameter was significantly larger in the remnant group at 6 and 12 months (both P < .001). Hemodynamically, the proximal inflow zone was more frequently observed in the remnant group at 6 months. Several preprocedural ostium hemodynamic parameters were significantly higher in the remnant group. As a prediction for occlusion, the areas under the curve of the ostium maximum diameter (for 6 and 12 months), systolic inflow rate ratio (for 6 months), and systolic inflow area (for 12 months) reached 0.843, 0.883, 0.855, and 0.860, respectively.
CONCLUSIONS: Intracranial aneurysms with a large ostium and strong ostium inflow may need a longer time for occlusion. Preprocedural 4D flow MR imaging can well illustrate ostium hemodynamics and characterize aneurysm treatment responses.
© 2020 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2020        PMID: 32054620      PMCID: PMC7077913          DOI: 10.3174/ajnr.A6413

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  34 in total

1.  Enhanced aneurysmal flow diversion using a dynamic push-pull technique: an experimental and modeling study.

Authors:  D Ma; J Xiang; H Choi; T M Dumont; S K Natarajan; A H Siddiqui; H Meng
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-24       Impact factor: 3.825

2.  The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

3.  Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial.

Authors:  Tibor Becske; David F Kallmes; Isil Saatci; Cameron G McDougall; István Szikora; Giuseppe Lanzino; Christopher J Moran; Henry H Woo; Demetrius K Lopes; Aaron L Berez; Daniel J Cher; Adnan H Siddiqui; Elad I Levy; Felipe C Albuquerque; David J Fiorella; Zsolt Berentei; Miklós Marosfoi; Saruhan H Cekirge; Peter K Nelson
Journal:  Radiology       Date:  2013-02-15       Impact factor: 11.105

4.  Quantified aneurysm shape and rupture risk.

Authors:  Madhavan L Raghavan; Baoshun Ma; Robert E Harbaugh
Journal:  J Neurosurg       Date:  2005-02       Impact factor: 5.115

5.  Natural history of asymptomatic unruptured cerebral aneurysms evaluated at CT angiography: growth and rupture incidence and correlation with epidemiologic risk factors.

Authors:  J Pablo Villablanca; Gary R Duckwiler; Reza Jahan; Satoshi Tateshima; Neil A Martin; John Frazee; Nestor R Gonzalez; James Sayre; Fernando V Vinuela
Journal:  Radiology       Date:  2013-07-02       Impact factor: 11.105

6.  Observer agreement in the assessment of endovascular aneurysm therapy and aneurysm recurrence.

Authors:  H J Cloft; T Kaufmann; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

Review 7.  Basic neuroangiography: review of technique and perioperative patient care.

Authors:  Sun Ho Ahn; Ethan A Prince; Gregory J Dubel
Journal:  Semin Intervent Radiol       Date:  2013-09       Impact factor: 1.513

8.  Current Trends and Results of Endovascular Treatment of Unruptured Intracranial Aneurysms at a Single Institution in the Flow-Diverter Era.

Authors:  O Petr; W Brinjikji; H Cloft; D F Kallmes; G Lanzino
Journal:  AJNR Am J Neuroradiol       Date:  2016-01-21       Impact factor: 3.825

9.  Assessment of intra-aneurysmal flow modification after flow diverter stent placement with four-dimensional flow MRI: a feasibility study.

Authors:  Vitor Mendes Pereira; Olivier Brina; Benedicte M A Delattre; Rafik Ouared; Pierre Bouillot; Gorislav Erceg; Karl Schaller; Karl-Olof Lovblad; Maria-Isabel Vargas
Journal:  J Neurointerv Surg       Date:  2014-10-03       Impact factor: 5.836

10.  Effect of aneurysm and ICA morphology on hemodynamics before and after flow diverter treatment.

Authors:  Ignacio Larrabide; Arjan J Geers; Hernán G Morales; Martha L Aguilar; Daniel A Rüfenacht
Journal:  J Neurointerv Surg       Date:  2014-04-01       Impact factor: 5.836

View more
  4 in total

1.  The effect of Dean, Reynolds and Womersley numbers on the flow in a spherical cavity on a curved round pipe. Part 2. The haemodynamics of intracranial aneurysms treated with flow-diverting stents.

Authors:  Michael C Barbour; Fanette Chassagne; Venkat K Chivukula; Nathanael Machicoane; Louis J Kim; Michael R Levitt; Alberto Aliseda
Journal:  J Fluid Mech       Date:  2021-03-31       Impact factor: 3.627

2.  The effect of Dean, Reynolds, and Womersley number on the flow in a spherical cavity on a curved round pipe. Part 1. Fluid mechanics in the cavity as a canonical flow representing intracranial aneurysms.

Authors:  Fanette Chassagne; Michael C Barbour; Venkat K Chivukula; Nathanael Machicoane; Louis J Kim; Michael R Levitt; Alberto Aliseda
Journal:  J Fluid Mech       Date:  2021-03-31       Impact factor: 3.627

3.  Hemodynamic Analysis of Pipeline Embolization Device Stent for Treatment of Giant Intracranial Aneurysm under Unsupervised Learning Algorithm.

Authors:  Haibin Gao; Wei You; Jian Lv; Youxiang Li
Journal:  J Healthc Eng       Date:  2022-01-04       Impact factor: 2.682

4.  Definition and extraction of 2D shape indices of intracranial aneurysm necks for rupture risk assessment.

Authors:  Sarah Mittenentzwei; Oliver Beuing; Belal Neyazi; I Erol Sandalcioglu; Naomi Larsen; Bernhard Preim; Sylvia Saalfeld
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-08-18       Impact factor: 2.924

  4 in total