| Literature DB >> 32041567 |
Yu-Yi Huang1, Tung-Yi Lin2, Chien-Hao Chen1, Ying-Chao Chou3, Chun-Yi Su1.
Abstract
BACKGROUND: To compare the outcomes after surgical intervention, including external fixation (EF) with the optional addition of K-pins or open reduction and internal fixation (ORIF) with a volar locking plate (VLP), in patients with distal radius fracture aged > 80 years.Entities:
Keywords: Distal radius fracture; Elderly; External fixation; Surgical treatment; Volar locking plate
Mesh:
Year: 2020 PMID: 32041567 PMCID: PMC7011248 DOI: 10.1186/s12891-020-3101-3
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Fig. 1a, b; The anteroposterior and lateral plain films showed an intra-articular comminuted distal radius fracture. c, d; Immediate postoperative anteroposterior and lateral plain films presented after adequate reduction and volar plating fixation
Fig. 2a, b; The anteroposterior and lateral plain films showed an intra-articular comminuted distal radius fracture with dorsal displacement. c, d; Immediate postoperative anteroposterior and lateral plain films presented after adequate reduction, external fixator and K-pins fixation
Demographic data of the patients
| External fixation | Volar locking plate | ||
|---|---|---|---|
| Mean age, years (range) | 84 (80–97) | 84 (80–96) | 0.53 |
| Male/Female | 6/35 | 4/24 | 0.97 |
| Type of fracture | 0.46 | ||
| Extra-articular | 17 (41%) | 9 (32%) | |
| Intra-articular | 24 (59%) | 19 (68%) | |
| OTA classification | 0.51 | ||
| A2 | 11 (27%) | 9 (32%) | |
| A3 | 8 (19%) | 2 (7%) | |
| C1 | 6 (15%) | 7 (25%) | |
| C2 | 6 (15%) | 5 (18%) | |
| C3 | 10 (24%) | 5 (18%) | |
| Operation time, mins | 58 ± 19 | 97 ± 29 | |
| Hospital stay, days | 2 ± 1 | 3 ± 1 | |
| Follow-up time, years | 1.3 ± 0.4 | 1.4 ± 0.4 | 0.38 |
Significant p values are shown in bold. CVA Cerebrovascular accident, CAD Coronary artery disease, OTA Orthopaedic Trauma Association
Comparison of radiographic data between EF group and VLP group
| External fixation | Volar locking plate | ||
|---|---|---|---|
| Preoperative | |||
| Radial height (mm) | 5.4 ± 4.6 | 6.9 ± 3.9 | 0.19 |
| Ulnar variance (mm) | 5.1 ± 3.4 | 4.8 ± 4.1 | 0.59 |
| Radial inclination (°) | 12.8 ± 7.2 | 15.0 ± 7.5 | 0.23 |
| Palmar tilt (°) | −10.6 ± 18.4 | −12.6 ± 16.3 | 0.41 |
| Associated ulnar styloid fracture | 23 | 11 | 0.22 |
| Postoperative day 1 | |||
| Radial height (mm) | 10.1 ± 2.9 | 11.2 ± 2.9 | 0.21 |
| Ulnar variance (mm) | 1.2 ± 2.4 | 1.4 ± 2.3 | 0.68 |
| Radial inclination (°) | 21.7 ± 32.4 | 22.8 ± 5.0 | 0.63 |
| Palmar tilt (°) | 0.4 ± 8.5 | 2.8 ± 8.5 | 0.25 |
| Final follow-up | |||
| Radial height (mm) | 8.8 ± 3.2 | 11.2 ± 5.4 | 0.06 |
| Ulnar variance (mm) | 3.5 ± 2.8 | 1.8 ± 3.2 | |
| Radial inclination (°) | 19.1 ± 5.9 | 22.1 ± 5.2 | |
| Palmar tilt (°) | 1.7 ± 9.9 | −0.32 ± 8.0 | 0.37 |
Significant p values are shown in bold
Comparison of wrist range of motion between EF group and VLP group
| External fixation | Volar locking plate | ||
|---|---|---|---|
| Flexion (°) | 61.9 ± 10.0 | 65.2 ± 7.6 | 0.15 |
| Extension (°) | 58.6 ± 7.7 | 61.1 ± 11.6 | 0.28 |
| Supination (°) | 74.7 ± 6.6 | 80 ± 7.2 | |
| Pronation (°) | 78.5 ± 8.6 | 82.5 ± 8.0 | 0.054 |
Significant p values are shown in bold
Complications
| External fixation | Volar locking plate | ||
|---|---|---|---|
| Overall incidence of complications | 22 (54%) | 5 (18%) | |
| Infection | 11 (27%) | 1 (4%) | |
| Chronic regional pain syndrome | 2 (5%) | 0 (0%) | 0.24 |
| Wrist stiffness | 6 (15%) | 2 (7%) | 0.34 |
| Tendonitis | 5 (12%) | 2 (7%) | 0.50 |
| Neuropathy | 1 (2%) | 1 (4%) | 0.79 |
| Implant failure | 2 (5%) | 0 (0%) | 0.24 |
Significant p values are shown in bold