Literature DB >> 19741409

Displaced distal radial fractures treated using volar locking plates: maintenance of normal anatomy.

Iain Stevenson1, Carol A Carnegie, Eva M Christie, Kapil Kumar, Alan J Johnstone.   

Abstract

BACKGROUND: The objective is to assess the ability of volar locking plates to maintain fracture reduction when used to treat dorsally displaced extra- and intra-articular distal radial fractures.
METHODS: This prospective study was conducted over an 12-month period. Consenting patients who had sustained a closed, dorsally displaced distal radial fracture, treated by open reduction and internal fixation using a volar distal radial locking plate were included in the study. Radial inclination, volar tilt, and ulnar variance were measured from radiographs taken at least 3 months after surgery and compared with radiographs of the uninjured side. Only two of the eight participating surgeons have a specialist interest in upper limb surgery.
RESULTS: Thirty-three patients were included in the study. There were 23 women and 10 men. The mean age was 49.5 years (range, 26-82 years). According to the Orthopaedic Trauma Association (OTA) classification, there were 19 Type A, 1 Type B, and 13 Type C fractures. The average restoration of volar tilt was 1-degree angle of under correction with a range of 7.3-degree angle of under correction to 3.7-degree angle of over correction, when compared with the uninjured side. The mean restoration of radial inclination was 1.9-degree angle of under correction with a range of 10-degree angle of under correction to 8.4-degree angle of over correction. As a group, the mean ulnar variance was 0 mm with a range of 2 mm of relative ulnar shortening to 3.5 mm of ulnar prominence when compared with the uninjured side.
CONCLUSION: In the hands of general trauma surgeons, the volar approach combined with the application of a suitable volar locking plate is a good treatment for restoring and maintaining the anatomy of dorsally displaced intra- and extra-articular distal radial fractures.

Entities:  

Mesh:

Year:  2009        PMID: 19741409     DOI: 10.1097/TA.0b013e3181ad8d4d

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  7 in total

1.  A comparative study of Colles' fractures in patients between fifty and seventy years of age: percutaneous K-wiring versus volar locking plating.

Authors:  Yih-Shiunn Lee; Tien-Yung Wei; Yu-Chieh Cheng; Tzu-Liang Hsu; Chien-Rae Huang
Journal:  Int Orthop       Date:  2011-12-13       Impact factor: 3.075

2.  Volar locking plate fixation for distal radius fractures: Does age affect outcome?

Authors:  Ahmed Ezzat; Santosh Baliga; Carol Carnegie; Alan Johnstone
Journal:  J Orthop       Date:  2016-02-22

3.  Comparison between external fixators and fixed-angle volar-locking plates in the treatment of distal radius fractures.

Authors:  Alberto Agustín Jorge-Mora; David Cecilia-López; Victor Rodríguez-Vega; Laura Suárez-Arias; Eva Andrés-Esteban; Miguel Ángel Porras-Moreno; Carlos Resines-Erasun
Journal:  J Hand Microsurg       Date:  2012-06-16

4.  Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life.

Authors:  Serafim Tsitsilonis; David Machó; Sebastian Manegold; Björn Dirk Krapohl; Florian Wichlas
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2016-07-28

5.  Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes.

Authors:  Murat Çalbıyık; Deniz Ipek
Journal:  Med Sci Monit       Date:  2018-01-30

6.  Melone's concept revisited in comminuted distal radius fractures: the three-dimensional CT mapping.

Authors:  Shuang Li; Ying-Qi Zhang; Gu-Heng Wang; Kai Li; Jian Wang; Ming Ni
Journal:  J Orthop Surg Res       Date:  2020-06-16       Impact factor: 2.359

7.  Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate.

Authors:  Yu-Yi Huang; Tung-Yi Lin; Chien-Hao Chen; Ying-Chao Chou; Chun-Yi Su
Journal:  BMC Musculoskelet Disord       Date:  2020-02-10       Impact factor: 2.362

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.