Literature DB >> 32030945

[Application of three-dimensional reconstruction simulation to define the starting point of lumbar cortical bone trajectory].

Zhen Huang1, Ning Sun1, Jiabin Ren1, Rui Li1, Xin Liu1, Yuefei Li1, Jingwei Bi1, Zhaozhong Sun1.   

Abstract

OBJECTIVE: CT three-dimensional reconstruction technology was used to simulate the placement of the lumbar cortical bone trajectory (CBT), to determine the starting point and direction of the screw trajectory.
METHODS: Between February 2017 and April 2018, 24 patients with lumbar CT were selected as the study object. There were 7 males and 17 females, with an average age of 50.4 years (range, 37-68 years). The CT DICOM data of patients were imported into Mimics 16.0 software, and the three-dimensional model of lumbar spine was established. A 5 mm diameter cylinder was set up to simulate the CBT by using Mimics 16.0 software. According to the different implant schemes, the study was divided into groups A, B, and C, the track of the screw respectively passed through the upper edge, the medial edge, and the lower edge of the isthmus of the pedicle. The intersection of simulated screw and lumbar spine was marked as region of interest (ROI) and a mask was generated. The average CT value [Hounsfield unit (HU)] and the screw length of ROI were automatically measured by Mimics 16.0 software. In addition, the head inclination angle and head camber angle of the screw were measured respectively. Point F was the intersection of the level of the lowest edge of the transverse process and the lumbar isthmus periphery. The horizontal and vertical distance between point F and the starting point were measured, and the relationship between the three schemes and the position of the zygapophysial joint and spinous process was observed.
RESULTS: Plan A has the highest ROI average HU, with the maximum value appearing in L 4; plan B has the longest screw length, with the maximum value appearing in L 5; plan C has the largest nail track head inclination angle, with the maximum value appearing in L 4; plan B has the largest nail track head camber angle, with the maximum value appearing in L 3. The screw length and head camber angle of the nail in group B were significantly greater than those in groups A and C ( P<0.05); the head inclination angle in groups A, B, and C was gradually increased, showing significant differences ( P<0.05); there was no significant difference in the average HU value of ROI between the 3 groups ( P>0.05). In plan A, 74.48% (143/192) screws had a horizontal distance of -2 to 4 mm from point F, a vertical distance of 6-14 mm from point F, a head inclination angle of (14.64±2.77)°, and a head camber angle of (6.55±2.09)°, respectively; in plan B, 84.58% (203/240) screws had a horizontal distance of 1-6 mm from point F, a vertical distance of 1-5 mm from point F, a head inclination angle of (26.93±2.21)°, and a head camber angle of (10.29±2.46)°, respectively; in plan C, 85.94% (165/192) screws had a horizontal distance of -2 to 3 mm from point F, a vertical distance of -2 to 4 mm from point F, a head inclination angle of (33.50±3.69)°, and a head camber angle of (6.47±2.48)°, respectively.
CONCLUSION: Plan B should be selected as the starting point of the L 1-L 5 CBT implant. It is located at the intersection of the lowest horizontal line of the transverse process root and the lateral edge of the lumbar isthmus, which is 1-6 mm horizontally inward, 1-5 mm vertically upward, with a head inclination angle of (26.93±2.21)°, and a head camber angle of (10.29±2.46)°, respectively.

Entities:  

Keywords:  CT three-dimensional reconstruction; Cortical bone trajectory; lumbar; osteoporosis

Mesh:

Year:  2020        PMID: 32030945      PMCID: PMC8171979          DOI: 10.7507/1002-1892.201908087

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  15 in total

1.  Effects of endplate removal on the structural properties of the lower lumbar vertebral bodies.

Authors:  Thomas R Oxland; J Pamela Grant; Marcel F Dvorak; Charles G Fisher
Journal:  Spine (Phila Pa 1976)       Date:  2003-04-15       Impact factor: 3.468

2.  Should we use cortical bone screws for cortical bone trajectory?

Authors:  Masaki Ueno; Rina Sakai; Kensei Tanaka; Gen Inoue; Kentaro Uchida; Takayuki Imura; Wataru Saito; Toshiyuki Nakazawa; Naonobu Takahira; Kiyoshi Mabuchi; Masashi Takaso
Journal:  J Neurosurg Spine       Date:  2015-01-16

3.  Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management.

Authors:  Joseph J Schreiber; Paul A Anderson; Humberto G Rosas; Avery L Buchholz; Anthony G Au
Journal:  J Bone Joint Surg Am       Date:  2011-06-01       Impact factor: 5.284

4.  [Observation of lumbar zygapophyseal joints adjacent arterials by anatomy and DSA].

Authors:  Yan Cheng; Zhaozhong Sun; Rui Li; Qingmin Fang; Guanglin Wang; Jiabin Ren
Journal:  Zhonghua Yi Xue Za Zhi       Date:  2015-07-21

5.  Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography.

Authors:  Keitaro Matsukawa; Yoshiyuki Yato; Osamu Nemoto; Hideaki Imabayashi; Takashi Asazuma; Koichi Nemoto
Journal:  J Spinal Disord Tech       Date:  2013-08

6.  Effect of the degree of osteoporosis on the biomechanical anchoring strength of the sacral pedicle screws: an in vitro comparison between unaugmented bicortical screws and polymethylmethacrylate augmented unicortical screws.

Authors:  Xin-Ming Zhuang; Bin-Sheng Yu; Zhao-Min Zheng; Jia-Fang Zhang; William W Lu
Journal:  Spine (Phila Pa 1976)       Date:  2010-09-01       Impact factor: 3.468

7.  Cortical bone trajectory for lumbar pedicle screws.

Authors:  B G Santoni; R A Hynes; K C McGilvray; G Rodriguez-Canessa; A S Lyons; M A W Henson; W J Womack; C M Puttlitz
Journal:  Spine J       Date:  2008-09-14       Impact factor: 4.166

8.  Bone mineral density values derived from routine lumbar spine multidetector row CT predict osteoporotic vertebral fractures and screw loosening.

Authors:  B J Schwaiger; A S Gersing; T Baum; P B Noël; C Zimmer; J S Bauer
Journal:  AJNR Am J Neuroradiol       Date:  2014-03-13       Impact factor: 3.825

9.  Evaluation of MR Spectroscopy and Diffusion-Weighted MRI in Postmenopausal Bone Strength.

Authors:  Kanhaiya Agrawal; Yatish Agarwal; Rajesh K Chopra; Achla Batra; Ranjan Chandra; Brij B Thukral
Journal:  Cureus       Date:  2015-09-21

10.  The Effects of Spinopelvic Parameters and Paraspinal Muscle Degeneration on S1 Screw Loosening.

Authors:  Jin-Bum Kim; Seung-Won Park; Young-Seok Lee; Taek-Kyun Nam; Yong-Sook Park; Young-Baeg Kim
Journal:  J Korean Neurosurg Soc       Date:  2015-10-30
View more
  1 in total

1.  Finite Element Analysis of Femoral-Acetabular Impingement (FAI) Based on Three-Dimensional Reconstruction.

Authors:  Xi Luo; Jun Zhang; Guofeng Cai; Yuqiong Wu; Kun Ma
Journal:  J Healthc Eng       Date:  2022-02-27       Impact factor: 2.682

  1 in total