| Literature DB >> 32020882 |
Chuang Liu1, Allieu Kamara2, Tianjing Liu2, Yunhui Yan3, Enbo Wang4.
Abstract
BACKGROUND: Management of distal humerus metaphyseal-diaphyseal junction (MDJ) region fractures can be very challenging mainly because of the higher location and characteristics of the fracture lines. Loss of reduction is relatively higher in MDJ fractures treated with classical supracondylar humerus fractures (SHFs) fixation techniques.Entities:
Keywords: Biomechanical study; Elastic stable intramedullary nails; External fixator; Finite element analysis; Metaphyseal-diaphyseal junction fracture; Pinning fixation; Supracondylar humerus fracture
Mesh:
Year: 2020 PMID: 32020882 PMCID: PMC7001280 DOI: 10.1186/s13018-020-1564-4
Source DB: PubMed Journal: J Orthop Surg Res ISSN: 1749-799X Impact factor: 2.359
Fig. 1Fixation simulations for the transverse fracture model. 2C, two-crossed pins (1-medial and 1-lateral K-wires); 3C, three-crossed pins (1-medial and 2-lateral K-wires); 2L, two-lateral pins (2-divergent lateral K-wires); 3L, three-lateral pins (3-divergent lateral K-wires); ESIN, elastic stable intramedullary nails; EF, lateral external fixation system
Fig. 2Fixation simulations for the medial oblique fracture model. 2C, two-crossed pins (1-medial and 1-lateral K-wires); 3MC, three-crossed pins (2-medial and 1-lateral K-wires); 2M, two-medial pins (2-divergent medial K-wires); ESIN, elastic stable intramedullary nails; EF, lateral external fixation system
Fig. 3Fixation simulations for the lateral oblique fracture model. 2C, two-crossed pins (1-medial and 1-lateral K-wires); 3C, three-crossed pins (1-medial and 2-lateral K-wires); 2L, two-lateral pins (2-divergent lateral K-wires); 3L, three-lateral pins (3- divergent lateral K-wires); ESIN, elastic stable intramedullary nails; EF, lateral external fixation system
Material properties, number of elements, and nodes of the finite element model
| Material | Element type | Young’s modulus (MPa) | Poison’s ratio | Number of element | Number of nodes |
|---|---|---|---|---|---|
| Cortical bone | C3D4 | 16,000 | 0.3 | 56,678 | 15,617 |
| Cancellous bone | C3D4 | 150 | 0.3 | 48,736 | 10,906 |
| K-wire | C3D8R | 200,000 | 0.33 | 456 | 696 |
| ESIN | C3D8R | 110,000 | 0.33 | 1872 | 2618 |
| External fixator | C3D8R and C3D4 | 200,000 | 0.33 | 5359 | 3837 |
Stiffness values for the transverse fracture model fixation simulation
| Fixation | Flexion | Extension | Valgus | Varus | Internal rotation | External rotation |
|---|---|---|---|---|---|---|
| 2C | 23.3100 | 5.1800 | 14.7275 | 14.8157 | 172.4983 | 172.9134 |
| 3C | 33.6587 | 11.2196 | 21.7328 | 33.6587 | 187.7382 | 189.1732 |
| 2L | 19.3562 | 10. 6235 | 21.6709 | 27.5811 | 93.8844 | 93.8896 |
| 3L | 29.3542 | 14.6771 | 23.7567 | 30.2358 | 101.6560 | 101.2576 |
| EF | 28.1955 | 6.2657 | 11.4714 | 14.6000 | 85.1572 | 84.5978 |
| ESIN | 22.1607 | 12.3115 | 14.9275 | 14.0977 | 149.6425 | 149.4406 |
Data of flexion, extension, valgus, and varus loadings are in N/mm, while data of internal and external rotations are in Nmm/°. 2C two-crossed pins (1-medial and 1-lateral K-wires), 3C three-crossed pins (1-medial and 2-lateral K-wires), 2L 2-lateral K-wires, 3L 3-lateral K-wires, EF lateral external fixator, ESIN elastic stable intramedullary nails
Stiffness values for the medial oblique fracture model fixation simulation
| Fixation | Flexion | Extension | Valgus | Varus | Internal rotation | External rotation |
|---|---|---|---|---|---|---|
| 2C | 25.7397 | 25.651 | 14. 7933 | 16.5231 | 148.796 | 217.5591 |
| 3MC | 48.9950 | 31.0508 | 17.7905 | 21.2805 | 173.7579 | 257.8124 |
| 2M | 28.9209 | 30.452 | 14. 8697 | 19.1903 | 82.7283 | 89.3163 |
| EF | 52.0703 | 62.5383 | 28.8646 | 21.6523 | 61.6056 | 57.4632 |
| ESIN | 22.5832 | 22.5884 | 11.9323 | 15.3845 | 139.5170 | 134.9637 |
Data of flexion, extension, valgus, and varus loadings are in N/mm, while data of internal and external rotations are in Nmm/°. 2C two-crossed pins (1-medial and 1-lateral K-wires), 3C three-crossed pins (1-medial and 2-lateral K-wires), 2M 2-medial K-wires, EF lateral external fixator, ESIN elastic stable intramedullary nails
Stiffness values for the lateral oblique fracture model fixation simulation
| Fixation | Flexion | Extension | Valgus | Varus | Internal rotation | External rotation |
|---|---|---|---|---|---|---|
| 2C | 108.1910 | 113.6450 | 193.1430 | 169.0100 | 183.8870 | 184.3140 |
| 3C | 125.8300 | 129.5290 | 225.7960 | 173.0010 | 221.9005 | 238.4727 |
| 2L | 102.0450 | 81.5110 | 189.2530 | 133.0720 | 89.6237 | 91.0009 |
| 3L | 110.5610 | 82.4640 | 202.7530 | 146.5370 | 95.3620 | 98.2150 |
| EF | 61.9450 | 51.2210 | 124.6650 | 171.7150 | 62.5179 | 68.1112 |
| ESIN | 121.9760 | 139.6650 | 236.4530 | 204.6500 | 154.9460 | 146.6370 |
Data of flexion, extension, valgus, and varus loadings are in N/mm, while data of internal and external rotations are in Nmm/°. 2C two-crossed pins (1-medial and 1-lateral K-wires), 3C three-crossed pins (1-medial and 2-lateral K-wires), 2L 2-lateral K-wires, 3L 3-lateral K-wires, EF lateral external fixator, ESIN elastic stable intramedullary nails