Literature DB >> 31985604

Quantitative Knee Arthrography in a Large Animal Model of Osteoarthritis Using Photon-Counting Detector CT.

Kishore Rajendran1, Naveen S Murthy1, Matthew A Frick1, Shengzhen Tao1, Mark D Unger2, Katherine T LaVallee3, Nicholas B Larson4, Shuai Leng1, Timothy P Maus1, Cynthia H McCollough1.   

Abstract

OBJECTIVE: The aim of this study was to grade cartilage damage in a swine model of osteoarthritis using a whole-body photon-counting detector (PCD) CT.
MATERIALS AND METHODS: A multienergy phantom containing gadolinium (Gd) (2, 4, 8, and 16 mg/mL) and hydroxyapatite (200 and 400 mg/cc) was scanned using a PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs, D50 reconstruction kernel) to serve as calibration for material decomposition and to assess quantification accuracy. Osteoarthritis was induced in Yucatan miniswine (n = 8) using 1.2 mg monoiodoacetate (MIA) injected into a randomized knee, whereas the contralateral control knee received saline. Twenty-one days later, a contrast bolus (gadoterate meglumine, 4 mL/knee) was intra-articularly administered into both knees. The knees were simultaneously scanned on the PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs). Multienergy images were reconstructed with a sharp "V71" kernel and a quantitative "D50" kernel. Image denoising was applied to the V71 images before grading cartilage damage, and an iterative material decomposition technique was applied to D50 images to generate the Gd maps. Two radiologists blinded to the knee injection status graded the cartilage integrity based on a modified International Cartilage Repair Society scoring system. Histology was performed on excised cartilage using methylene blue/basic fuchsin. Statistical analysis of grade distribution was performed using an exact test of omnibus symmetry with P < 0.05 considered significant.
RESULTS: Material decomposed images from the multienergy phantom scan showed delineation and quantification of Gd and hydroxyapatite with a root-mean-squared error of 0.3 mg/mL and 18.4 mg/cc, respectively. In the animal cohort, the radiologists reported chondromalacia in the MIA knees with International Cartilage Repair Society scores ranging from grade 1 (cartilage heterogeneity, n = 4 knees) to grade 3 (up to 100% cartilage loss, n = 4 knees). Grade 1 was characterized by cartilage heterogeneity and increased joint space in the patellofemoral compartment, whereas grade 3 was characterized by cartilage erosion and bone-on-bone articulation in the patellofemoral compartment. All control knees were scored as grade 0 (normal cartilage). Significant difference (P = 0.004) was observed in the grade distribution between the MIA and control knees. Gross examination of the excised knees showed cartilage lesions in the grade 3 MIA knees. The Gd maps from material decomposition showed lower contrast levels in the joint space of the MIA knee compared with the contralateral control knee due to joint effusion. Histology revealed chondrocyte loss in the MIA knee cartilage confirming the chondrotoxic effects of MIA on cartilage matrix.
CONCLUSIONS: We demonstrated a high-resolution and quantitative PCD-CT arthrography technique for grading cartilage damage in a large animal model of osteoarthritis. Photon-counting detector CT offers simultaneous high-resolution and multienergy imaging capabilities that allowed morphological assessment of cartilage loss and quantification of contrast levels in the joint as a marker of joint disease. Cartilage damage in the MIA knees was graded using PCD-CT images, and the image-based findings were further confirmed using histology and gross examination of the excised knees.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31985604      PMCID: PMC7212750          DOI: 10.1097/RLI.0000000000000648

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   10.065


  32 in total

1.  Multidetector computed tomography arthrography of the knee: diagnostic accuracy and indications.

Authors:  Massimo De Filippo; Annalisa Bertellini; Francesco Pogliacomi; Nicola Sverzellati; Domenico Corradi; Giacomo Garlaschi; Maurizio Zompatori
Journal:  Eur J Radiol       Date:  2008-03-10       Impact factor: 3.528

2.  Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system.

Authors:  Shuai Leng; Zhicong Yu; Ahmed Halaweish; Steffen Kappler; Katharina Hahn; Andre Henning; Zhoubo Li; John Lane; David L Levin; Steven Jorgensen; Erik Ritman; Cynthia McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-22

3.  Material decomposition with prior knowledge aware iterative denoising (MD-PKAID).

Authors:  Shengzhen Tao; Kishore Rajendran; Cynthia H McCollough; Shuai Leng
Journal:  Phys Med Biol       Date:  2018-09-21       Impact factor: 3.609

4.  High-Resolution Chest Computed Tomography Imaging of the Lungs: Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography.

Authors:  David J Bartlett; Chi Wan Koo; Brian J Bartholmai; Kishore Rajendran; Jayse M Weaver; Ahmed F Halaweish; Shuai Leng; Cynthia H McCollough; Joel G Fletcher
Journal:  Invest Radiol       Date:  2019-03       Impact factor: 6.016

5.  Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.

Authors:  Rolf Symons; Daniel S Reich; Mohammadhadi Bagheri; Tyler E Cork; Bernhard Krauss; Stefan Ulzheimer; Steffen Kappler; David A Bluemke; Amir Pourmorteza
Journal:  Invest Radiol       Date:  2018-03       Impact factor: 6.016

6.  Analysis of cartilage matrix fixed charge density and three-dimensional morphology via contrast-enhanced microcomputed tomography.

Authors:  Ashley W Palmer; Robert E Guldberg; Marc E Levenston
Journal:  Proc Natl Acad Sci U S A       Date:  2006-12-08       Impact factor: 11.205

Review 7.  Animal models of osteoarthritis: challenges of model selection and analysis.

Authors:  Erin Teeple; Gregory D Jay; Khaled A Elsaid; Braden C Fleming
Journal:  AAPS J       Date:  2013-01-18       Impact factor: 4.009

8.  Axial Spondyloarthritis: Dual-Energy Virtual Noncalcium CT in the Detection of Bone Marrow Edema in the Sacroiliac Joints.

Authors:  Haijun Wu; Guangfeng Zhang; Lei Shi; Xiuhui Li; Min Chen; Xiaoyu Huang; Ximing Cao; Shaoheng Tan; Yang Cui; Changhong Liang
Journal:  Radiology       Date:  2018-10-23       Impact factor: 11.105

9.  Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging: Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis.

Authors:  Grischa Bratke; Tilman Hickethier; Daniel Bar-Ness; Alexander Christian Bunck; David Maintz; Gregor Pahn; Philippe Coulon; Salim Si-Mohamed; Philippe Douek; Monica Sigovan
Journal:  Invest Radiol       Date:  2020-02       Impact factor: 6.016

10.  A review of translational animal models for knee osteoarthritis.

Authors:  Martin H Gregory; Nicholas Capito; Keiichi Kuroki; Aaron M Stoker; James L Cook; Seth L Sherman
Journal:  Arthritis       Date:  2012-12-27
View more
  6 in total

1.  Ultra-high resolution computed tomography of joints: practical recommendations for acquisition protocol optimization.

Authors:  Pedro Augusto Gondim Teixeira; Nicolas Villani; Malik Ait Idir; Edouard Germain; Charles Lombard; Romain Gillet; Alain Blum
Journal:  Quant Imaging Med Surg       Date:  2021-10

2.  Photon Counting CT: Clinical Applications and Future Developments.

Authors:  Scott S Hsieh; Shuai Leng; Kishore Rajendran; Shengzhen Tao; Cynthia H McCollough
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-08-28

3.  High Resolution, Full Field-of-View, Whole Body Photon-Counting Detector CT: System Assessment and Initial Experience.

Authors:  Kishore Rajendran; Jeff Marsh; Martin Petersilka; André Henning; Elisabeth Shanblatt; Bernhard Schmidt; Thomas Flohr; Joel Fletcher; Cynthia McCollough; Shuai Leng
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

4.  Deep Learning-Based CT Imaging to Evaluate the Therapeutic Effects of Acupuncture and Moxibustion Therapy on Knee Osteoarthritis.

Authors:  Guoyong Jiang; Jianguang Ding; Chenglu Ge
Journal:  Comput Math Methods Med       Date:  2022-05-21       Impact factor: 2.809

5.  Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography: A Feasibility Animal Study.

Authors:  Liqiang Ren; Kishore Rajendran; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  Invest Radiol       Date:  2020-10       Impact factor: 10.065

6.  Quantitative dual contrast photon-counting computed tomography for assessment of articular cartilage health.

Authors:  Petri Paakkari; Satu I Inkinen; Miitu K M Honkanen; Mithilesh Prakash; Rubina Shaikh; Miika T Nieminen; Mark W Grinstaff; Janne T A Mäkelä; Juha Töyräs; Juuso T J Honkanen
Journal:  Sci Rep       Date:  2021-03-10       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.