Literature DB >> 30351251

Axial Spondyloarthritis: Dual-Energy Virtual Noncalcium CT in the Detection of Bone Marrow Edema in the Sacroiliac Joints.

Haijun Wu1, Guangfeng Zhang1, Lei Shi1, Xiuhui Li1, Min Chen1, Xiaoyu Huang1, Ximing Cao1, Shaoheng Tan1, Yang Cui1, Changhong Liang1.   

Abstract

Purpose To determine the diagnostic performance of dual-energy virtual noncalcium (VNCa) CT in the detection of bone marrow edema in study participants with sacroiliitis associated with axial spondyloarthritis. Materials and Methods In this prospective study, 47 consecutive participants (mean age, 27 years; age range, 14-41 years [28 male; mean age, 24 years; age range, 14-37 years] [19 female; mean age, 29 years; age range, 17-41 years]) underwent dual-energy CT and 3.0-T MRI between April 2016 and December 2017. Two independent readers visually evaluated all sacroiliac joints for the presence of abnormal marrow attenuation on dual-energy VNCa images using a four-point classification system (0, no edema; 1, mild edema; 2, moderate edema; 3, severe edema). CT numbers on VNCa images were determined with region-of-interest-based quantitative analysis. MRI was the reference standard for presence of bone marrow edema. Results Sensitivity, specificity, and accuracy of readers 1 and 2, respectively, in the identification of bone edema at CT were 87% and 93% (48 and 51 of 55), 94% and 91% (32 and 31 of 34), and 90% and 92% (80 and 82 of 89). Interobserver agreement was excellent (κ = 0.81). CT numbers from VNCa images increased from no edema to severe edema (P < .001). The area under the receiver operating characteristic curve was 0.93 for reader 1 and 0.91 for reader 2 in differentiation of the presence of bone marrow edema from no edema. A cutoff value of -33 HU derived from reader 1 yielded overall sensitivity, specificity, and accuracy of 90% (49 of 55), 83% (28 of 34), and 87% (77 of 89) in the detection of any extent of edema in the sacroiliac joints. Conclusion Dual-energy VNCa CT images had excellent diagnostic performance in evaluation of the extent of bone marrow edema in study participants with sacroiliitis associated with axial spondyloarthritis. © RSNA, 2018 See also the editorial by Guggenberger in this issue.

Entities:  

Mesh:

Year:  2018        PMID: 30351251     DOI: 10.1148/radiol.2018181168

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

Review 1.  Imaging in rheumatoid arthritis: the role of magnetic resonance imaging and computed tomography.

Authors:  Mikkel Østergaard; Mikael Boesen
Journal:  Radiol Med       Date:  2019-03-18       Impact factor: 3.469

Review 2.  The application of dual-energy computed tomography in the diagnosis of musculoskeletal disorders: a review of current concepts and applications.

Authors:  Marina Carotti; Fausto Salaffi; Giacomo Beci; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2019-03-04       Impact factor: 3.469

3.  Imaging update in spondyloarthropathy.

Authors:  Amit Shah; Neel Raja; Winston J Rennie
Journal:  J Clin Orthop Trauma       Date:  2021-08-13

Review 4.  Use of Imaging in Axial Spondyloarthritis for Diagnosis and Assessment of Disease Remission in the Year 2022.

Authors:  Ann-Sophie De Craemer; Zuzanna Łukasik; Philippe Carron
Journal:  Curr Rheumatol Rep       Date:  2022-10-15       Impact factor: 4.686

Review 5.  Recognizing and Minimizing Artifacts at Dual-Energy CT.

Authors:  Anushri Parakh; Chansik An; Simon Lennartz; Prabhakar Rajiah; Benjamin M Yeh; Frank J Simeone; Dushyant V Sahani; Avinash R Kambadakone
Journal:  Radiographics       Date:  2021-02-19       Impact factor: 5.333

6.  Quantitative Knee Arthrography in a Large Animal Model of Osteoarthritis Using Photon-Counting Detector CT.

Authors:  Kishore Rajendran; Naveen S Murthy; Matthew A Frick; Shengzhen Tao; Mark D Unger; Katherine T LaVallee; Nicholas B Larson; Shuai Leng; Timothy P Maus; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2020-06       Impact factor: 10.065

7.  Evaluating the temporomandibular joint disc using calcium-suppressed technique in dual-layer detector computed tomography.

Authors:  Xiaohuan Zhang; Mengqi Liu; Yanyi Wang; Weiwei Deng; Houmin Tan; Wenping Fan; Zhiye Chen
Journal:  J Int Med Res       Date:  2019-12-18       Impact factor: 1.671

8.  Imaging update in inflammatory arthritis.

Authors:  Iwona Sudoł-Szopińska; Chiara Giraudo; Edwin H G Oei; Lennart Jans
Journal:  J Clin Orthop Trauma       Date:  2021-06-30

9.  Choose wisely: imaging for diagnosis of axial spondyloarthritis.

Authors:  Torsten Diekhoff; Iris Eshed; Felix Radny; Katharina Ziegeler; Fabian Proft; Juliane Greese; Dominik Deppe; Robert Biesen; Kay Geert Hermann; Denis Poddubnyy
Journal:  Ann Rheum Dis       Date:  2021-05-28       Impact factor: 19.103

Review 10.  Virtual non-calcium dual-energy CT: clinical applications.

Authors:  Tommaso D'Angelo; Moritz H Albrecht; Danilo Caudo; Silvio Mazziotti; Thomas J Vogl; Julian L Wichmann; Simon Martin; Ibrahim Yel; Giorgio Ascenti; Vitali Koch; Giuseppe Cicero; Alfredo Blandino; Christian Booz
Journal:  Eur Radiol Exp       Date:  2021-09-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.