Literature DB >> 31983484

Comparison of Sound Touch Elastography, Shear Wave Elastography and Vibration-Controlled Transient Elastography in Chronic Liver Disease Assessment using Liver Biopsy as the "Reference Standard".

Ilias Gatos1, Petros Drazinos2, Spyros Yarmenitis2, Ioannis Theotokas2, Pavlos S Zoumpoulis3.   

Abstract

Chronic liver disease (CLD) is currently a major cause of death. Ultrasound elastography (USE) is an imaging method that has been developed for CLD assessment. Our aim in the study described here was to evaluate and compare a new commercial variant of USE, sound touch elastography (STE), with already established USE methods, shear wave elastography (SWE) and vibration-controlled transient elastography (VCTE), using liver biopsy as the "reference standard." For our study, 139 consecutive patients underwent standard liver STE, SWE and VCTE examinations with the corresponding ultrasound devices. A receiver operator characteristic (ROC) curve analysis was performed on the stiffness values measured with each method. ROC analysis revealed, for SWE, STE and VCTE, areas under the ROC curve of 0.9397, 0.9224 and 0.9348 for fibrosis stage (F), F ≥ F1; 0.9481, 0.9346 and 0.9415 for F ≥ F2; 0.9623, 0.9591 and 0.9631 for F ≥ F3; and 0.9581, 0.9541 and 0.9632 for F = F4, respectively. In conclusion, STE performs similarly to SWE and VCTE in CLD stage differentiation.
Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Chronic liver disease; Fibrosis; Shear wave elastography; Sound touch elastography; Vibration-controlled transient elastography

Year:  2020        PMID: 31983484     DOI: 10.1016/j.ultrasmedbio.2019.12.016

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Shear wave elastography using sound touch elastography and supersonic shear imaging for liver measurements: a comparative study.

Authors:  Hongjin Xiang; Wenwu Ling; Lin Ma; Lulu Yang; Tang Lin; Yan Luo
Journal:  Quant Imaging Med Surg       Date:  2022-05

2.  Shear wave-based sound touch elastography in liver fibrosis assessment for patients with autoimmune liver diseases.

Authors:  Lulu Yang; Wenwu Ling; Du He; Changli Lu; Lin Ma; Lin Tang; Yan Luo; Shigao Chen
Journal:  Quant Imaging Med Surg       Date:  2021-04

3.  Quantitative ultrasound, elastography, and machine learning for assessment of steatosis, inflammation, and fibrosis in chronic liver disease.

Authors:  François Destrempes; Marc Gesnik; Boris Chayer; Marie-Hélène Roy-Cardinal; Damien Olivié; Jeanne-Marie Giard; Giada Sebastiani; Bich N Nguyen; Guy Cloutier; An Tang
Journal:  PLoS One       Date:  2022-01-27       Impact factor: 3.240

4.  Ultrasound score combined with liver stiffness measurement by sound touch elastography for staging liver fibrosis in patients with chronic hepatitis B: a clinical prospective study.

Authors:  Kun Huang; Qinyuan Li; Weimei Zeng; Xin Chen; Li Liu; Xiang Wan; Cheng Feng; Zhiyan Li; Zhong Liu; Changfeng Dong
Journal:  Ann Transl Med       Date:  2022-03

5.  Comparison of Visual Transient Elastography and Shear Wave Elastography in Evaluating Liver Fibrosis in Patients with Chronic Liver Disease.

Authors:  Jiali Yang; Jiawu Li; Guilin Ye; Yan Luo
Journal:  Int J Gen Med       Date:  2021-07-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.