Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure-volume relationships in man.

D A Kass1, M Midei, W Graves, J A Brinker, W L Maughan.   

Abstract

Determination of left ventricular pressure-volume relationships in situ ideally requires both a method for easy measurement of multiple pressure-volume loops and a rapid and reversible means of altering load. We report a technique, previously used in animals, that combines conductance catheter volumes and rapid inferior vena caval occlusion to permit routine measurement of calibrated P-V relationships in man for the first time. An 8F volume catheter with a 3F micromanometer tipped pressure catheter placed through its lumen was advanced to the left ventricular apex through a femoral artery. A thermodilution output catheter was placed through a 9F femoral venous sheath and later replaced with an IVC balloon occlusion catheter, through which a 2.5F bipolar wire was advanced for atrial pacing. A specialized data system facilitated collection, editing, and data analysis at the time of cardiac catheterization. Absolute volume calibration required cardiac output measurement and injection of hypertonic saline. IVC occlusion decreased peak left ventricular pressure by 42 +/- 17 (SD) (P less than .001) mm Hg in 15 patients. Endsystolic pressure-volume relationships (ESPVR) were determined with 5-8 cardiac cycles with an average of r2 of 0.94 +/- 0.05 and were generally reproducible. The slope of the ESPVR demonstrated consistency among a group of normal patients (n = 6), and was significantly lower than the slope derived from a group of patients with ventricular hypertrophy (n = 9). We conclude that left ventricular pressure-volume relationships can be easily and repeatedly determined as part of a routine cardiac catheterization in man.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3197110     DOI: 10.1002/ccd.1810150314

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  40 in total

1.  Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

Authors:  M C Herrera; J M Olivera; M E Valentinuzzi
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

2.  Computerized left ventricular pressure-volume relationships (pV-loops) using disposable angiographic tip transducer pigtail catheters.

Authors:  U Raff; T F Culclasure; C Clark; L Overturf; B M Groves
Journal:  Int J Card Imaging       Date:  2000-02

3.  Impact of surrounding tissue on conductance measurement of coronary and peripheral lumen area.

Authors:  Hyo Won Choi; Benjamin Jansen; Zhen-Du Zhang; Ghassan S Kassab
Journal:  J R Soc Interface       Date:  2012-06-20       Impact factor: 4.118

Review 4.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis.

Authors:  Ramakrishna Mukkamala; Da Xu
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-09       Impact factor: 4.733

Review 5.  Ventriculo-arterial coupling: concepts, assumptions, and applications.

Authors:  D A Kass; R P Kelly
Journal:  Ann Biomed Eng       Date:  1992       Impact factor: 3.934

Review 6.  Ventriculovascular coupling in systolic and diastolic heart failure.

Authors:  Justin M Fox; Mathew S Maurer
Journal:  Curr Heart Fail Rep       Date:  2005-12

7.  Ventriculovascular coupling in systolic and diastolic heart failure.

Authors:  Justin M Fox; Mathew S Maurer
Journal:  Curr Cardiol Rep       Date:  2006-05       Impact factor: 2.931

8.  Measurement of cardiac function using pressure-volume conductance catheter technique in mice and rats.

Authors:  Pál Pacher; Takahiro Nagayama; Partha Mukhopadhyay; Sándor Bátkai; David A Kass
Journal:  Nat Protoc       Date:  2008       Impact factor: 13.491

9.  Validation of noninvasive indices of global systolic function in patients with normal and abnormal loading conditions: a simultaneous echocardiography pressure-volume catheterization study.

Authors:  Raquel Yotti; Javier Bermejo; Yolanda Benito; Ricardo Sanz-Ruiz; Cristina Ripoll; Pablo Martínez-Legazpi; Candelas Pérez del Villar; Jaime Elízaga; Ana González-Mansilla; Alicia Barrio; Rafael Bañares; Francisco Fernández-Avilés
Journal:  Circ Cardiovasc Imaging       Date:  2013-10-30       Impact factor: 7.792

10.  Defibrillation efficacy with endocardial electrodes is influenced by reductions in cardiac preload.

Authors:  J S Strobel; G N Kay; G P Walcott; W M Smith; R E Ideker
Journal:  J Interv Card Electrophysiol       Date:  1997-09       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.