Literature DB >> 3196544

In vivo evaluation of a peripheral vascular access axial flow blood pump.

R K Wampler1, J C Moise, O H Frazier, D B Olsen.   

Abstract

More than 80 acute and chronic calf in vivo studies were utilized to develop a 3 L/min axial flow blood pump designed for intraarterial ventricular assist. The 7 mm diameter transvalvular inlet cannula of the cable driven pump receives blood from the left ventricle. The pump then discharges blood into the descending aorta. In the calf, the pump was introduced into the renal aorta. Safety and effectiveness of the device were demonstrated in three control and 21 implanted animals. Blood chemistry results showed an average plasma free hemoglobin of 3 mg/dl for control and 6.7 mg/dl for implanted animals. Platelets were 1.04 X 10(6) and 0.65 X 10(6), respectively, for control and implanted animals. Fibrinogen, BUN, creatinine, and bilirubin were essentially the same for both groups of animals. The hardware was typically free of deposits, and histopathologic examination revealed minimal injury to intracardiac structures, aortic valve leaflets, and aortic intima. The data indicates that the device may provide full support for a failing left ventricle with minimal trauma or risk.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3196544

Source DB:  PubMed          Journal:  ASAIO Trans        ISSN: 0889-7190


  9 in total

1.  The use of mechanical assist devices in the management of cardiogenic shock. Secondary to acute myocardial infarction.

Authors:  R W Smalling
Journal:  Tex Heart Inst J       Date:  1991

2.  Management of patients supported on the Hemopump cardiac assist system.

Authors:  R T Baldwin; B Radovancević; J M Duncan; R K Wampler; O H Frazier
Journal:  Tex Heart Inst J       Date:  1992

Review 3.  Total artificial hearts: past, present, and future.

Authors:  William E Cohn; Daniel L Timms; O H Frazier
Journal:  Nat Rev Cardiol       Date:  2015-06-02       Impact factor: 32.419

4.  Bud Frazier's 1,000 th implantation of a ventricular assist device.

Authors:  Mark S Slaughter
Journal:  Tex Heart Inst J       Date:  2014-04-01

Review 5.  [Reperfusion therapy and mechanical circulatory support in patients in cardiogenic shock].

Authors:  K H Scholz
Journal:  Herz       Date:  1999-10       Impact factor: 1.443

Review 6.  The Impella Device: Historical Background, Clinical Applications and Future Directions.

Authors:  James J Glazier; Amir Kaki
Journal:  Int J Angiol       Date:  2018-12-20

7.  PediaFlow™ Maglev Ventricular Assist Device: A Prescriptive Design Approach.

Authors:  James F Antaki; Michael R Ricci; Josiah E Verkaik; Shaun T Snyder; Timothy M Maul; Jeongho Kim; Dave B Paden; Marina V Kameneva; Bradley E Paden; Peter D Wearden; Harvey S Borovetz
Journal:  Cardiovasc Eng       Date:  2010-03-01

8.  Integrated unit for programmable control of the 21F Hemopump and registration of physiological signals.

Authors:  E E Kunst; J A van Alsté; T Arts; H B Boom
Journal:  Med Biol Eng Comput       Date:  1994-11       Impact factor: 2.602

9.  Peripheral organ perfusion augmentation during left ventricular failure. A controlled bovine comparison between the intraaortic balloon pump and the Hemopump.

Authors:  R T Baldwin; B Radovancević; J L Conger; R Matsuwaka; J M Duncan; W K Vaughn; R K Wampler; O H Frazier
Journal:  Tex Heart Inst J       Date:  1993
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.