Literature DB >> 8298324

Peripheral organ perfusion augmentation during left ventricular failure. A controlled bovine comparison between the intraaortic balloon pump and the Hemopump.

R T Baldwin1, B Radovancević, J L Conger, R Matsuwaka, J M Duncan, W K Vaughn, R K Wampler, O H Frazier.   

Abstract

Despite the use of inotropic therapy and the intraaortic balloon pump (IABP), inadequate peripheral organ perfusion and subsequent multiorgan failure from left ventricular dysfunction is a major cause of death following cardiac surgery. To compare the end-organ perfusion provided by the IABP with that of the recently developed Hemopump Cardiac Assist System, blood flow from visceral organs was measured by ultrasonic flow probes during separate periods of support with each of these pumps. Ten calves underwent coronary artery ligations with beta-receptor blockade; hemodynamic parameters were recorded before the induction of failure, during unsupported cardiac failure, and during Hemopump and IABP support. Improvement in mean cardiac output, mixed venous oxygen saturation, and pulmonary artery wedge pressure was significantly greater (p < 0.05) during Hemopump support than during IABP support. Renal artery flow was significantly greater during Hemopump support (276 +/- 74.2 cc/min) than during IABP support (164 +/- 79.6 cc/min). Hepatic artery flow was significantly greater during Hemopump support (34.7 +/- 25.7 cc/min) than during IABP support (24.4 +/- 18.9 cc/min), and portal vein flow was significantly greater during Hemopump support (1588 +/- 315 cc/min) than IABP support (1259 +/- 310 cc/min). There were no significant differences, however, between carotid artery flow during Hemopump support (292 +/- 171 cc/min) and that during IABP support (317 +/- 204 cc/min). We conclude that renal, hepatic, and mesenteric perfusion provided by the nonpulsatile Hemopump is superior to that of the IABP in this bovine model of left ventricular failure. Therefore, the Hemopump may be more effective in preventing multiorgan failure during recovery of ventricular function.

Entities:  

Mesh:

Year:  1993        PMID: 8298324      PMCID: PMC325110     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  18 in total

1.  Assisted circulation. I. The arterial counterpulsator.

Authors:  R H CLAUSS; W C BIRTWELL; G ALBERTAL; S LUNZER; W J TAYLOR; A M FOSBERG; D E HARKEN
Journal:  J Thorac Cardiovasc Surg       Date:  1961-04       Impact factor: 5.209

2.  Management of patients supported on the Hemopump cardiac assist system.

Authors:  R T Baldwin; B Radovancević; J M Duncan; R K Wampler; O H Frazier
Journal:  Tex Heart Inst J       Date:  1992

3.  Diastolic balloon pumping (with carbon dioxide) in the aorta--a mechanical assistance to the failing circulation.

Authors:  S D MOULOPOULOS; S TOPAZ; W J KOLFF
Journal:  Am Heart J       Date:  1962-05       Impact factor: 4.749

4.  Effects of left ventricular assist for cardiogenic shock on cardiac function and organ blood flow distribution.

Authors:  S Sukehiro; W Flameng
Journal:  Ann Thorac Surg       Date:  1990-09       Impact factor: 4.330

5.  Intraaortic balloon pumping in the experimental animal. Effects and problems.

Authors:  M Feola; M Adachi; W W Akers; J N Ross; D W Wieting; J H Kennedy
Journal:  Am J Cardiol       Date:  1971-02       Impact factor: 2.778

6.  In vivo evaluation of a peripheral vascular access axial flow blood pump.

Authors:  R K Wampler; J C Moise; O H Frazier; D B Olsen
Journal:  ASAIO Trans       Date:  1988 Jul-Sep

7.  A model to predict survival at time of postcardiotomy intraaortic balloon pump insertion.

Authors:  R T Baldwin; S Slogoff; G P Noon; M Sekela; O H Frazier; S K Edelman; W K Vaughn
Journal:  Ann Thorac Surg       Date:  1993-04       Impact factor: 4.330

8.  Effects of intraaortic balloon pumping on organ perfusion in cardiogenic shock.

Authors:  J N Bhayana; S M Scott; G K Sethi; T Takaro
Journal:  J Surg Res       Date:  1979-02       Impact factor: 2.192

9.  Splanchnic blood flow response to intraaortic balloon pump assist of hemorrhagic shock.

Authors:  R J Landreneau; J W Horton; R P Cochran
Journal:  J Surg Res       Date:  1991-10       Impact factor: 2.192

10.  Quality of life in long-term survivors of the Hemopump left ventricular assist device.

Authors:  R T Baldwin; B Radovancevic; J M Duncan; S Ford; J L Lonquist; E Munoz; N L Abou-Awdi; O H Frazier
Journal:  ASAIO Trans       Date:  1991 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.