Literature DB >> 3196517

Long-term stability of electroenzymatic glucose sensors implanted in mice. An update.

L C Clark1, R B Spokane, M M Homan, R Sudan, M Miller.   

Abstract

Protection of the enzyme layer of glutaraldehyde vapor-stabilized glucose oxidase-based glucose sensors from attack by proteolytic enzymes and peritoneal macrophages can be accomplished by covering with a regenerated cellulose (viscose) membrane, as commonly used for laboratory dialysis. These implanted sensors are not externally polarized, but continuously consume oxygen and glucose and generate gluconic acid and hydrogen peroxide. On the average (sensors in 45 mice) the activity declines with time, almost vanishing by 600 days. However, the fact that some sensors retain nearly all of their activity for over 500 days indicates that glucose sensors can be made with a life span compatible with the requirements for an artificial pancreas (glucose sensor/insulin pump). Limited observation with similar implanted lactate sensors indicates their life span to be shorter.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3196517

Source DB:  PubMed          Journal:  ASAIO Trans        ISSN: 0889-7190


  6 in total

Review 1.  In vitro, in vivo and post explantation testing of glucose-detecting biosensors: current methods and recommendations.

Authors:  Heidi E Koschwanez; William M Reichert
Journal:  Biomaterials       Date:  2007-04-19       Impact factor: 12.479

Review 2.  A tale of two compartments: interstitial versus blood glucose monitoring.

Authors:  Eda Cengiz; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

Review 3.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

4.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

5.  Microdialysis sampling extraction efficiency of 2-deoxyglucose: role of macrophages in vitro and in vivo.

Authors:  Xiaodun Mou; Julie A Stenken
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

6.  Consistency of Continuous Ambulatory Interstitial Glucose Monitoring Sensors.

Authors:  Pei T Wu; David E Segovia; Cathy C Lee; Kim-Lien Nguyen
Journal:  Biosensors (Basel)       Date:  2018-05-16
  6 in total