Literature DB >> 31944935

Bootstrap-Optimised Regularised Image Reconstruction for Emission Tomography.

Andrew J Reader, Sam Ellis.   

Abstract

In emission tomography, iterative image reconstruction from noisy measured data usually results in noisy images, and so regularisation is often used to compensate for noise. However, in practice, an appropriate, automatic and precise specification of the strength of regularisation for image reconstruction from a given noisy measured dataset remains unresolved. Existing approaches are either empirical approximations with no guarantee of generalisation, or else are computationally intensive cross-validation methods requiring full reconstructions for a limited set of preselected regularisation strengths. In contrast, we propose a novel methodology embedded within iterative image reconstruction, using one or more bootstrapped replicates of the measured data for precise optimisation of the regularisation. The approach uses a conventional unregularised iterative update of a current image estimate from the noisy measured data, and then also uses the bootstrap replicate to obtain a bootstrap update of the current image estimate. The method then seeks the regularisation hyperparameters which, when applied to the bootstrap update of the image, lead to a best fit of the regularised bootstrap update to the conventional measured data update. This corresponds to estimating the degree of regularisation needed in order to map the noisy update to a model of the mean of an ensemble of noisy updates. For a given regularised objective function (e.g. penalised likelihood), no hyperparameter selection or tuning is required. The method is demonstrated for positron emission tomography (PET) data at different noise levels, and delivers near-optimal reconstructions (in terms of reconstruction error) without any knowledge of the ground truth, nor any form of training data.

Entities:  

Mesh:

Year:  2020        PMID: 31944935      PMCID: PMC7273977          DOI: 10.1109/TMI.2019.2956878

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  23 in total

1.  Evaluation of three MRI-based anatomical priors for quantitative PET brain imaging.

Authors:  Kathleen Vunckx; Ameya Atre; Kristof Baete; Anthonin Reilhac; Christophe M Deroose; Koen Van Laere; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2011-10-27       Impact factor: 10.048

2.  Comparison of bootstrap resampling methods for 3-D PET imaging.

Authors:  C Lartizien; J-B Aubin; I Buvat
Journal:  IEEE Trans Med Imaging       Date:  2010-04-19       Impact factor: 10.048

3.  The image quality of FBP and MLEM reconstruction.

Authors:  Herfried Wieczorek
Journal:  Phys Med Biol       Date:  2010-05-17       Impact factor: 3.609

Review 4.  Iterative reconstruction techniques in emission computed tomography.

Authors:  Jinyi Qi; Richard M Leahy
Journal:  Phys Med Biol       Date:  2006-07-12       Impact factor: 3.609

5.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

6.  Evaluation of Parallel Level Sets and Bowsher's Method as Segmentation-Free Anatomical Priors for Time-of-Flight PET Reconstruction.

Authors:  Georg Schramm; Martin Holler; Ahmadreza Rezaei; Kathleen Vunckx; Florian Knoll; Kristian Bredies; Fernando Boada; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2018-02       Impact factor: 10.048

7.  Assessment of bootstrap resampling performance for PET data.

Authors:  P J Markiewicz; A J Reader; J C Matthews
Journal:  Phys Med Biol       Date:  2014-12-09       Impact factor: 3.609

Review 8.  4D image reconstruction for emission tomography.

Authors:  Andrew J Reader; Jeroen Verhaeghe
Journal:  Phys Med Biol       Date:  2014-10-31       Impact factor: 3.609

9.  PET image reconstruction using kernel method.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2014-07-30       Impact factor: 10.048

10.  Multi-Tracer Guided PET Image Reconstruction.

Authors:  Sam Ellis; Andrew Mallia; Colm J McGinnity; Gary J R Cook; Andrew J Reader
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-07-23
View more
  1 in total

1.  MR-guided motion-corrected PET image reconstruction for cardiac PET-MR.

Authors:  Camila Munoz; Sam Ellis; Stephan G Nekolla; Karl P Kunze; Teresa Vitadello; Radhouene Neji; Rene M Botnar; Julia A Schnabel; Andrew J Reader; Claudia Prieto
Journal:  J Nucl Med       Date:  2021-05-28       Impact factor: 11.082

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.