Literature DB >> 31879494

Biomechanical properties of an intramedullary suture anchor fixation compared to tension band wiring in osteoporotic olecranon fractures- A cadaveric study.

Arvind von Keudell1,2,3, Amir Kachooei4, Amin Mohamadi1, Sharri J Mortensen1, Stephen Okajima1, Jonathan Egan1, MichaelJ Weaver2,3, George S M Dyer2,3, Ara Nazarian1,3.   

Abstract

INTRODUCTION: The aim of the study is to compare three different fixation techniques for transverse olecranon repair in cadaveric osteoporotic bone: (1) current recommended AO tension band technique with K-wire fixation; (2) Suture anchor fixation and (3) Polyester suture fixation.
METHODS: Evaluated with bone densitometry, 7 osteoporotic human elbow specimens were included in the study. A transverse olecranon fracture was reduced anatomically and were fixated first using a K-wire tension band technique, second using two suture anchors, and third using polyester suture. Static simulations of the kinetics associated with active range of motion (AROM) and push up from a chair exercises were performed with cyclic loading using Instron hydraulic testing apparatus. Fracture displacement was measured using videographic analysis. Failure was defined as 2 mm fracture displacement.
RESULTS: The biomechanical analysis found no statistical difference in displacements between the three fixation methods when testing AROM. In simulated push-up exercises, polyester suture fixation failed after 17 cycles and had significantly higher displacement compared to the other two methods. No difference between the K-Wire fixation versus Suture anchor fixation was observed, p = 0.162.
CONCLUSION: Suture anchor fixation might be a viable surgical treatment option for osteoporotic transverse elbow fractures in geriatric patients.
© 2019 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cadaveric study; Complications; K-wire fixation; Olecranon fractures; Osteoporosis; Suture anchor fixation

Year:  2019        PMID: 31879494      PMCID: PMC6919365          DOI: 10.1016/j.jor.2019.08.002

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  19 in total

1.  Mechanical stability affects angiogenesis during early fracture healing.

Authors:  Chuanyong Lu; Neema Saless; Diane Hu; Xiaodong Wang; Zhiqing Xing; Huagang Hou; Benjamin Williams; Harold M Swartz; Celine Colnot; Theodore Miclau; Ralph S Marcucio
Journal:  J Orthop Trauma       Date:  2011-08       Impact factor: 2.512

2.  Potential dangers of tension band wiring of olecranon fractures: an anatomic study.

Authors:  Louis W Catalano; Keith Crivello; Marissa Purcelli Lafer; Benjamin Chia; O Alton Barron; Steven Z Glickel
Journal:  J Hand Surg Am       Date:  2011-08-23       Impact factor: 2.230

Review 3.  Olecranon fractures: treatment options.

Authors:  D J Hak; G J Golladay
Journal:  J Am Acad Orthop Surg       Date:  2000 Jul-Aug       Impact factor: 3.020

Review 4.  Complications and re-operation rate after tension-band wiring of olecranon fractures.

Authors:  J M Romero; A Miran; C H Jensen
Journal:  J Orthop Sci       Date:  2000       Impact factor: 1.601

5.  Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures: evaluation of the transcortical K-wire technique.

Authors:  J J Candal-Couto; J R Williams; P L Sanderson
Journal:  J Orthop Trauma       Date:  2005-08       Impact factor: 2.512

6.  Biomechanical analysis of tension band fixation for olecranon fracture treatment.

Authors:  S H Kozin; L J Berglund; W P Cooney; B F Morrey; K N An
Journal:  J Shoulder Elbow Surg       Date:  1996 Nov-Dec       Impact factor: 3.019

7.  Transcortical screw fixation of the olecranon shows equivalent strength and improved stability compared with tension band fixation.

Authors:  Tyler B Jones; Andrew R Karenz; Paul S Weinhold; Laurence E Dahners
Journal:  J Orthop Trauma       Date:  2014-03       Impact factor: 2.512

8.  Methods of fixation of olecranon fractures. An experimental mechanical study.

Authors:  I S Fyfe; M M Mossad; B J Holdsworth
Journal:  J Bone Joint Surg Br       Date:  1985-05

9.  Monitoring the mechanical properties of healing bone.

Authors:  L E Claes; J L Cunningham
Journal:  Clin Orthop Relat Res       Date:  2009-02-26       Impact factor: 4.176

10.  Olecranon fractures repaired with FiberWire or metal wire tension banding: a biomechanical comparison.

Authors:  Bradley C Carofino; Stephen A Santangelo; Mitesh Kabadi; Augustus D Mazzocca; Bruce D Browner
Journal:  Arthroscopy       Date:  2007-09       Impact factor: 4.772

View more
  2 in total

1.  The Use of High Strength Sutures and Anchors in Olecranon Fractures: A Systematic Review.

Authors:  Omid Nazifi; Rajitha Gunaratne; Harry D'Souza; Aaron Tay
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-02-24

2.  The Efficacy of Suture Fixation of the Greater Trochanter in Unstable Intertrochanteric Fractures.

Authors:  Ki-Choul Kim; Hee-Gon Park; Jae-Wook Park
Journal:  Clin Orthop Surg       Date:  2021-07-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.