Literature DB >> 23681413

Transcortical screw fixation of the olecranon shows equivalent strength and improved stability compared with tension band fixation.

Tyler B Jones1, Andrew R Karenz, Paul S Weinhold, Laurence E Dahners.   

Abstract

OBJECTIVES: Currently, the standard for 21-B3.1 olecranon fracture fixation is the tension band wire construct described by the AO foundation. Although this technique effectively repairs displaced olecranon fractures and osteotomies, it is associated with a high rate of secondary surgery for implant removal due to hardware "back out," prominence, and discomfort. The senior author of this study has used transcortical screw fixation for olecranon fractures and osteotomies to avoid hardware discomfort but has been unable to find literature documenting the strength of this method. Accordingly, we compared the strength and stability of transcortical screw fixation with tension band fixation of simple transverse olecranon fractures under cyclical loading.
METHODS: Eighteen fourth-generation synthetic biomechanical testing ulnas underwent a transverse olecranon osteotomy and were repaired by tension banding or screw fixation. Two 4.0 mm partially threaded screws inserted across the fracture gap into the anterior cortex of the ulna achieved screw fixation. Ulnas were tested in 2 ways as follows: (1) cyclic loading that simulated pushing up from a chair; and (2) single cycle loading to failure. Fracture displacement was recorded using a transducer that was placed on the posterior surface of the ulna.
RESULTS: Differences between screw fixation and tension banding in the peak displacement during cyclic loading and single cycle load to failure were not significant. Screw fixation did show significantly less "trough" displacement (resting position between cycles) during cyclic loading indicating less plastic deformation.
CONCLUSIONS: In a synthetic bone model of simple transverse olecranon fractures, screw fixation provided equivalent strength and less plastic deformation as compared with tension banding.

Entities:  

Mesh:

Year:  2014        PMID: 23681413     DOI: 10.1097/BOT.0b013e31829a25d2

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  7 in total

1.  Olecranon fractures: do they lead to osteoarthritis? Long-term outcomes and complications.

Authors:  Juan Martín Patiño; Alejandro F Rullan Corna; Alejandro E Michelini; Ignacio M Abdon; Bruno Marinucci
Journal:  Int Orthop       Date:  2020-07-09       Impact factor: 3.075

2.  Olecranon fixation with two bicortical screws.

Authors:  James R Gill; Lieven Vermuyten; Sophie A Schenk; Josh C Y Ong; Willem Schenk
Journal:  Bone Jt Open       Date:  2020-11-02

3.  Factors Associated With Reoperation After Fixation of Displaced Olecranon Fractures.

Authors:  Femke M A P Claessen; Yvonne Braun; Rinne M Peters; George Dyer; Job N Doornberg; David Ring
Journal:  Clin Orthop Relat Res       Date:  2015-08-07       Impact factor: 4.176

4.  Biomechanical properties of an intramedullary suture anchor fixation compared to tension band wiring in osteoporotic olecranon fractures- A cadaveric study.

Authors:  Arvind von Keudell; Amir Kachooei; Amin Mohamadi; Sharri J Mortensen; Stephen Okajima; Jonathan Egan; MichaelJ Weaver; George S M Dyer; Ara Nazarian
Journal:  J Orthop       Date:  2019-08-07

5.  Comparison of Functional and Radiological Outcomes of Olecranon Fractures Treated with Tension Band Wiring with Kirschner Wires to Transcortical Screw Fixation-A Randomised Controlled Study.

Authors:  Siddhartha Sinha; Rajiv Maharjan; Guru P Khanal; Bishnu Pokharel; Nikhil Drolia; Sumit Gupta; Rajesh K Kanojia; Pashupati Chaudhary
Journal:  Strategies Trauma Limb Reconstr       Date:  2020 Sep-Dec

6.  Biomechanical Comparison of Olecranon Sled Versus Intramedullary Screw Tension Banding for Olecranon Osteotomies.

Authors:  Cameron Kia; Alex G Dukas; Silas T Marshall; Andreas Voss; Elifho Obopilwe; Bruce D Browner; Augustus D Mazzocca
Journal:  Orthop J Sports Med       Date:  2018-12-17

7.  Low-profile double plating versus dorsal LCP in stabilization of the olecranon fractures.

Authors:  Stefanie Hoelscher-Doht; A-M Kladny; M M Paul; L Eden; M Buesse; R H Meffert
Journal:  Arch Orthop Trauma Surg       Date:  2020-05-16       Impact factor: 3.067

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.