| Literature DB >> 31868013 |
Tobias Stornebrink1,2,3, Sjoerd A S Stufkens1,2,3, Daniel Appelt4, Coen A Wijdicks4, Gino M M J Kerkhoffs1,2,3.
Abstract
BACKGROUND: Technical innovation now offers the possibility of 2-mm-diameter operative tendoscopy with disposable arthroscopes and tablet-like control units. The promises of new technology should be critically scrutinized. Therefore, this study assessed whether 2-mm-diameter operative tendoscopy of the tibialis posterior, peroneal, and Achilles tendons was safe and effective in a cadaveric model.Entities:
Keywords: Achilles; ankle; efficacy; innovation; nanoscope; peroneals; safety; tendoscopy; tibialis posterior
Mesh:
Year: 2019 PMID: 31868013 PMCID: PMC7160745 DOI: 10.1177/1071100719895504
Source DB: PubMed Journal: Foot Ankle Int ISSN: 1071-1007 Impact factor: 2.827
Figure 1.The arthroscopic system that was used in this study consists of a tablet-like, medical-grade control unit and a separate, disposable handpiece.
Figure 2.Outside view during a 2-mm-diameter tendoscopic procedure. The camera is introduced through its tailored cannula.
Figure 3.Visualization of the tibialis posterior tendon during 2-mm-diameter tendoscopy. (1) Tibialis posterior tendon. (2) Tendon sheath.
Figure 4.Adhesions between the peritenon and Achilles tendon, visualized during insufflation with carbon dioxide. Hence, a successful adhesiolysis is well possible with 2-mm-diameter tendoscopy.
Figure 5.Visualization of a vinculum in the peroneal tendon sheet. If impingement complaints arise, a vinculum resection can be performed well through 2-mm-diameter operative tendoscopy. (1) Peroneus brevis tendon. (2) Peroneus longus tendon. (3) Vinculum. (4) Tailored arthroscopic biter, ready for vinculum release.
Distances Between Tendoscopic Portals and the Sural Nerve.
| Portal | Shapiro-Wilk | Mean Distance, mm | 95% CI | Cases of Contact |
|---|---|---|---|---|
| Peroneals, proximal | 0.85 (.061) | 14.5 | 11.4-17.7 | 0 |
| Peroneals, distal | 0.93 (.486) | 9.4 | 4.6-14.2 | 0 |
| Achilles, proximal | 0.92 (.343) | 13.4 | 9.1-17.6 | 0 |
| Achilles, distal | 0.95 (.637) | 17.7 | 12.2-23.3 | 0 |
Distances Between Tendoscopic Portals and the Posterior Neurovascular Bundle.
| Portal | Shapiro-Wilk | Mean Distance, mm | 95% CI | Median Distance, mm | Interquartile Range | Cases of Contact |
|---|---|---|---|---|---|---|
| Tibialis posterior, proximal | 0.79 (.012) | − | − | 11.6 | 11.3-16.3 | 0 |
| Tibialis posterior, distal | 0.95 (.655) | 19.2 | 15.6-22.9 | − | − | 0 |