| Literature DB >> 31867257 |
Jiin-Ling Jiang1, Jia-Lun Yu2, Jen-Hung Wang3, Yao-Yi Wang4, Wan-Hsiang Wang2.
Abstract
OBJECTIVE: The purpose of this study was to validate a Chinese version of the modified Standardized Swallowing Assessment (SSA) instrument used by nurses in stroke patients with dysphagia and explore the feasibility of the simplified instrument.Entities:
Keywords: Accuracy; Dysphagia; Stroke; Swallowing screen
Year: 2019 PMID: 31867257 PMCID: PMC6905239 DOI: 10.4103/tcmj.tcmj_158_18
Source DB: PubMed Journal: Ci Ji Yi Xue Za Zhi
Patient characteristics on the swallowing screen test (n=127)
| Item | Dysphagia | Total | ||
|---|---|---|---|---|
| No | Yes | |||
| Dysphagia, | 64 (50.4) | 63 (49.6) | 127 | |
| Gender, | ||||
| Male | 44 (68.7) | 44 (69.8) | 88 (69.3) | 0.894 |
| Female | 20 (31.3) | 19 (30.2) | 39 (30.7) | |
| Swallowing screen, | ||||
| Q1 | 7 (10.9) | 18 (28.6) | 25 (19.7) | 0.015* |
| Q2 | 6 (9.4) | 17 (27.0) | 23 (18.1) | 0.012* |
| Q3 | 11 (17.2) | 24 (38.1) | 35 (27.6) | 0.010* |
| Q4 | 2 (3.1) | 8 (12.7) | 10 (7.9) | <0.001* |
| Q5 | 18 (28.1) | 33 (52.4) | 51 (40.2) | 0.007* |
| Dimension 1 | 0.69±1.11 | 1.59±1.50 | 1.13±1.39 | 0.010* |
| Q6 | 13 (20.3) | 33 (52.4) | 46 (36.2) | <0.001* |
| Q7 | 16 (25.0) | 38 (60.3) | 54 (42.5) | <0.001* |
| Q8 | 24 (37.5) | 62 (98.4) | 86 (67.7) | <0.001* |
| Dimension 2 | 0.83±1.22 | 2.11±0.99 | 1.46±1.28 | <0.001* |
Data are presented as n or mean±SD.*P<0.05=Statistically significant. Q1: Voluntarily cough, Q2: Control saliva, Q3: Lick the top and bottom lips, Q4: Breathe freely, Q5: Not have a wet or hoarse voice, Q6: Give first 1 mL of water, Q7: Give second 1 mL of water, give third 1 mL of water, Q8: Give half a glass of water, SD: Standard deviation
Figure 1Scree plot showing the eigenvalue for each component in factor extraction of data obtained from a modified standardized swallowing assessment by nurses
Rotated factor matrix
| Item | Factor 1 | Factor 2 | Factor 3 |
|---|---|---|---|
| Q1 | 0.170 | 0.854a | 0.015 |
| Q2 | 0.302 | 0.191 | 0.392 |
| Q3 | 0.283 | 0.719a | 0.475 |
| Q4 | 0.085 | 0.053 | 0.877a |
| Q5 | 0.503a | 0.147 | 0.278 |
| Q6 | 0.850a | 0.223 | 0.217 |
| Q7 | 0.916a | 0.124 | 0.146 |
| Q8 | 0.630a | 0.137 | 0.028 |
aItem communality loading >0.5. Q1: Voluntarily cough, Q2: Control saliva, Q3: Lick the top and bottom lips, Q4: Breathe freely, Q5: Not have a wet or hoarse voice, Q6: Give first 1 mL of water, Q7: Give second 1 mL of water, give third 1 mL of water, Q8: Give half a glass of water
Comparison between model 1 and model 2 of the modified standardized swallowing assessment for dysphagia detection
| Outcome | Model 1 (original 8 items) | Model 2 (simplified 6 items) | ||||
|---|---|---|---|---|---|---|
| Low risk (<2) | High risk (≥2) | Total | Low risk (<2) | High risk (≥2) | Total | |
| Dysphagia | ||||||
| No | 38 | 26 | 64 | 41 | 23 | 64 |
| Yes | 11 | 52 | 63 | 12 | 51 | 63 |
| Total | 49 | 78 | 127 | 53 | 74 | 127 |
| AUC, 95% CI | 0.79 (0.71-0.87) | 0.79 (0.71-0.87) | ||||
| Sensitivity (%) | 82.50 | 81.00 | ||||
| Specificity (%) | 59.40 | 64.10 | ||||
| PPV (%) | 66.67 | 68.92 | ||||
| NPV (%) | 77.56 | 77.36 | ||||
| Accuracy (%) | 70.87 | 72.44 | ||||
| DOR (%) | 6.91 | 7.58 | ||||
AUC: Area under curve, PPV: Positive predictive value, NPV: Negative predictive value, DOR: Diagnostic odds ratio, CI: Confidence interval