Literature DB >> 31848517

[Influence of thread shapes of custommade root-analogue implants on stress distribution of peri-implant bone: A three-dimensional finite element analysis].

C P Lin1, S H Lu2, J X Zhu2, H C Hu2, Z G Yue2, Z H Tang2.   

Abstract

OBJECTIVE: To explore the effects from the thread shapes of custom-made root-analogue implant (RAI) on distributions of von Mises stress around the peri-implant bone.
METHODS: Five one-stage RAI three-dimensional finite element (FE) models with different thread shapes (V-shaped design, square design, buttress design, reverse buttress design and none thread design) and congruent bone were created through reverse engineering technology. The data of the five models were imported into the FE analysis software to calculate. A force of 100 N was applied parallelly and of 45° to the implant axis respectively. Analysis was performed to evaluate the von Mises stress distributions at the peri-implant regions with the help of the Ansys 16 software.
RESULTS: The von Mises stresses distributed mostly at the implant cervical regions and the tip ends of the threads on the cortical bone under oblique loading, while on the cancellous bone, the stresses concentrated mostly on the implant lateral cervical regions, the tip ends of the threads and the apical regions. When under vertical loading, the von Mises stresses distributed mostly at the implant cervical regions on the cortical bone while at the tip ends of the threads and the lateral apical regions on the cancellous bone. The von Mises stresses were better distributed on the thread groups under both kinds of loadings compared with no thread design. But there was no obvious difference among the different thread groups. The concentrations of the von Mises stresses on the cancellous bone in the thread groups were mostly at the tip ends of the threads while less in the apical area. The von Mises stresses were better distributed on the cancellous bone on the other three thread designs than on square design.
CONCLUSION: Thread designs are advocated for the reason that adding thread designs to the RAI standard design will have a positive effect on stress distributions at the peri-implant regions and it will reduce the concentrations of von Mises stresses on the cortical bone. From the standpoint of the stress distribution, V-shaped design, buttress design and reverse buttress design are more suitable for RAI than square design. There is no difference of the distributions of the von Mises stresses in the RAI between different thread designs.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31848517      PMCID: PMC7433572     

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  27 in total

1.  Influence of variations in implant diameters: a 3- to 5-year retrospective clinical report.

Authors:  C J Ivanoff; K Gröndahl; L Sennerby; C Bergström; U Lekholm
Journal:  Int J Oral Maxillofac Implants       Date:  1999 Mar-Apr       Impact factor: 2.804

2.  Custom-made, root-analogue direct laser metal forming implant: a case report.

Authors:  Francesco Guido Mangano; Bruno Cirotti; Rachel Lilian Sammons; Carlo Mangano
Journal:  Lasers Med Sci       Date:  2012-06-15       Impact factor: 3.161

Review 3.  The role of primary stability for successful immediate loading of dental implants. A literature review.

Authors:  Fawad Javed; George E Romanos
Journal:  J Dent       Date:  2010-06-11       Impact factor: 4.379

4.  Comparison of implant body designs and threaded designs of dental implants: a 3-dimensional finite element analysis.

Authors:  Heng-Li Huang; Chin-Han Chang; Jui-Ting Hsu; Alison M Fallgatter; Ching-Chang Ko
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Jul-Aug       Impact factor: 2.804

5.  Custom-made root analogue titanium implants placed into extraction sockets. An experimental study in monkeys.

Authors:  R J Kohal; M B Hürzeler; L F Mota; G Klaus; R G Caffesse; J R Strub
Journal:  Clin Oral Implants Res       Date:  1997-10       Impact factor: 5.977

6.  Distribution of micromotion in implants and alveolar bone with different thread profiles in immediate loading: a finite element study.

Authors:  Pei-Kun Chang; Yung-Chuan Chen; Ching-Chieh Huang; Wei-Hua Lu; Yi-Chun Chen; Hsun-Heng Tsai
Journal:  Int J Oral Maxillofac Implants       Date:  2012 Nov-Dec       Impact factor: 2.804

7.  Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis.

Authors:  Yasufumi Yamanishi; Satoshi Yamaguchi; Satoshi Imazato; Tamaki Nakano; Hirofumi Yatani
Journal:  Dent Mater       Date:  2012-08-21       Impact factor: 5.304

8.  The dental polymer implant concept.

Authors:  M Hodosh; M Povar; G Shklar
Journal:  J Prosthet Dent       Date:  1969-09       Impact factor: 3.426

9.  Finite Element Analysis of Bone Stress in the Posterior Mandible Using Regular and Short Implants, in the Same Context, with Splinted and Nonsplinted Prostheses.

Authors:  Marcelo Bighetti Toniollo; Ana Paula Macedo; Denise Pupim; Danilo Zaparolli; Maria da Gloria Chiarello de Mattos
Journal:  Int J Oral Maxillofac Implants       Date:  2017 Jul/Aug       Impact factor: 2.804

10.  Effects of implant thread geometry on percentage of osseointegration and resistance to reverse torque in the tibia of rabbits.

Authors:  Jennifer Steigenga; Khalaf Al-Shammari; Carl Misch; Francisco H Nociti; Hom-Lay Wang
Journal:  J Periodontol       Date:  2004-09       Impact factor: 6.993

View more
  1 in total

1.  The Importance of Correlation between CBCT Analysis of Bone Density and Primary Stability When Choosing the Design of Dental Implants-Ex Vivo Study.

Authors:  Mirko Mikic; Zoran Vlahovic; Momir Stevanović; Zoran Arsic; Rasa Mladenovic
Journal:  Tomography       Date:  2022-05-11
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.