Literature DB >> 22699801

Custom-made, root-analogue direct laser metal forming implant: a case report.

Francesco Guido Mangano1, Bruno Cirotti, Rachel Lilian Sammons, Carlo Mangano.   

Abstract

In the last few years, the application of digital technology in dentistry has become widespread with the introduction of cone beam computed tomography (CBCT) scan technology, and considerable progress has been made in the development of computer-aided design/ computer-aided manufacturing (CAD/CAM) techniques, including direct laser metal forming (DLMF). DLMF is a technology which allows solids with complex geometry to be produced by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model. For dental implants, the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer by layer, the desired object. At present, the combined use of CBCT 3D data and CAD/CAM technology makes it possible to manufacture custom-made, root-analogue implants (RAI) with sufficient precision. This report demonstrates the successful clinical use of a custom-made, root-analogue DLMF implant. CBCT images of a non-restorable right maxillary first premolar were acquired and transformed into a 3D model. From this model, a custom-made, root-analogue DLMF implant was fabricated. Immediately after tooth extraction, the RAI with a pre-operatively designed abutment was placed in the extraction socket and restored with a single crown. At the 1-year follow-up examination, the RAI showed a good functional and aesthetic integration. The introduction of DLMF technology signals the start of a new revolutionary era for implant dentistry as its immense potential for producing highly complex macro- and microstructures is receiving vast interest in different medical fields.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22699801     DOI: 10.1007/s10103-012-1134-z

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  13 in total

Review 1.  Implant plastic surgery: a review and rationale.

Authors:  Christopher E Kazor; Khalaf Al-Shammari; David P Sarment; Carl E Misch; Hom-Lay Wang
Journal:  J Oral Implantol       Date:  2004       Impact factor: 1.779

2.  Designing a novel dental root analogue implant using cone beam computed tomography and CAD/CAM technology.

Authors:  David Anssari Moin; Bassam Hassan; Peter Mercelis; Daniel Wismeijer
Journal:  Clin Oral Implants Res       Date:  2011-11-14       Impact factor: 5.977

3.  Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years follow-up.

Authors:  W Pirker; D Wiedemann; A Lidauer; A A Kocher
Journal:  Int J Oral Maxillofac Surg       Date:  2010-09-15       Impact factor: 2.789

Review 4.  Immediate implant placement: positives and negatives.

Authors:  Richard U Koh; Ivan Rudek; Hom-Lay Wang
Journal:  Implant Dent       Date:  2010-04       Impact factor: 2.454

5.  Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement.

Authors:  W Pirker; A Kocher
Journal:  Int J Oral Maxillofac Surg       Date:  2008-02-12       Impact factor: 2.789

6.  Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study.

Authors:  W Pirker; A Kocher
Journal:  Int J Oral Maxillofac Surg       Date:  2009-08-07       Impact factor: 2.789

7.  Custom-made root analogue titanium implants placed into extraction sockets. An experimental study in monkeys.

Authors:  R J Kohal; M B Hürzeler; L F Mota; G Klaus; R G Caffesse; J R Strub
Journal:  Clin Oral Implants Res       Date:  1997-10       Impact factor: 5.977

Review 8.  An overview of immediate root analogue zirconia implants.

Authors:  K M Regish; Deeksha Sharma; D R Prithviraj
Journal:  J Oral Implantol       Date:  2011-09-09       Impact factor: 1.779

9.  The dental polymer implant concept.

Authors:  M Hodosh; M Povar; G Shklar
Journal:  J Prosthet Dent       Date:  1969-09       Impact factor: 3.426

10.  Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series.

Authors:  Carlo Mangano; Adriano Piattelli; Mario Raspanti; Francesco Mangano; Alessandra Cassoni; Giovanna Iezzi; Jamil Awad Shibli
Journal:  Lasers Med Sci       Date:  2010-08-28       Impact factor: 3.161

View more
  13 in total

1.  Custom-made, selective laser sintering (SLS) blade implants as a non-conventional solution for the prosthetic rehabilitation of extremely atrophied posterior mandible.

Authors:  F Mangano; M Bazzoli; L Tettamanti; D Farronato; M Maineri; A Macchi; C Mangano
Journal:  Lasers Med Sci       Date:  2012-09-14       Impact factor: 3.161

2.  Immediate, non-submerged, root-analogue direct laser metal sintering (DLMS) implants: a 1-year prospective study on 15 patients.

Authors:  Francesco Guido Mangano; Michele De Franco; Alberto Caprioglio; Aldo Macchi; Adriano Piattelli; Carlo Mangano
Journal:  Lasers Med Sci       Date:  2013-03-15       Impact factor: 3.161

3.  [Influence of thread shapes of custommade root-analogue implants on stress distribution of peri-implant bone: A three-dimensional finite element analysis].

Authors:  C P Lin; S H Lu; J X Zhu; H C Hu; Z G Yue; Z H Tang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-12-18

Review 4.  Customized Root-Analogue Implants: A Review on Outcomes from Clinical Trials and Case Reports.

Authors:  Telma Dantas; Sara Madeira; Michael Gasik; Paula Vaz; Filipe Silva
Journal:  Materials (Basel)       Date:  2021-04-29       Impact factor: 3.623

Review 5.  Direct metal laser sintering titanium dental implants: a review of the current literature.

Authors:  F Mangano; L Chambrone; R van Noort; C Miller; P Hatton; C Mangano
Journal:  Int J Biomater       Date:  2014-12-01

6.  Maxillary overdentures supported by four splinted direct metal laser sintering implants: a 3-year prospective clinical study.

Authors:  Francesco Mangano; Fabrizia Luongo; Jamil Awad Shibli; Sukumaran Anil; Carlo Mangano
Journal:  Int J Dent       Date:  2014-12-14

7.  Accuracy Assessment of Three-dimensional Surface Reconstructions of In vivo Teeth from Cone-beam Computed Tomography.

Authors:  Yan-Hui Sang; Hong-Cheng Hu; Song-He Lu; Yu-Wei Wu; Wei-Ran Li; Zhi-Hui Tang
Journal:  Chin Med J (Engl)       Date:  2016-06-20       Impact factor: 2.628

8.  Impact of Cone Beam Computed Tomography Dose in Pre-Surgical Implant Analysis.

Authors:  Nabil El Sahili; Ibrahim Nasseh; Antoine Berberi; Sandra David-Tchouda; Sophie Thoret; Thomas Fortin
Journal:  Open Dent J       Date:  2018-01-31

9.  Digital versus Analog Procedures for the Prosthetic Restoration of Single Implants: A Randomized Controlled Trial with 1 Year of Follow-Up.

Authors:  Francesco Mangano; Giovanni Veronesi
Journal:  Biomed Res Int       Date:  2018-07-18       Impact factor: 3.411

10.  Custom-Made Direct Metal Laser Sintering Titanium Subperiosteal Implants: A Retrospective Clinical Study on 70 Patients.

Authors:  Mauro Cerea; Giorgio Andrea Dolcini
Journal:  Biomed Res Int       Date:  2018-05-28       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.